summaryrefslogtreecommitdiffstats
path: root/pychassisctl
diff options
context:
space:
mode:
authorBrad Bishop <bradleyb@fuzziesquirrel.com>2016-09-08 23:26:17 -0400
committerPatrick Williams <patrick@stwcx.xyz>2016-09-12 18:47:24 +0000
commit7a4d77a86e98f02839213ce040c1d8f2f6be31cc (patch)
tree1bbb7e8291400a6b9b82271ec398c8e1720b74ac /pychassisctl
parentcf98415545b993e4a1e24cbea7ad076a6b5ebb1d (diff)
downloadtalos-skeleton-7a4d77a86e98f02839213ce040c1d8f2f6be31cc.tar.gz
talos-skeleton-7a4d77a86e98f02839213ce040c1d8f2f6be31cc.zip
chassis: pep8 fixes
Change-Id: I6dc52616ce30660f2e6992f6e1a52d44dfec1cd7 Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
Diffstat (limited to 'pychassisctl')
-rw-r--r--pychassisctl/chassis_control.py18
1 files changed, 7 insertions, 11 deletions
diff --git a/pychassisctl/chassis_control.py b/pychassisctl/chassis_control.py
index 373d876..20532c9 100644
--- a/pychassisctl/chassis_control.py
+++ b/pychassisctl/chassis_control.py
@@ -20,7 +20,7 @@ BOOTED = 100
class ChassisControlObject(DbusProperties, DbusObjectManager):
def getUuid(self):
- uuid = "";
+ uuid = ""
try:
with open(MACHINE_ID) as f:
data = f.readline().rstrip('\n')
@@ -95,13 +95,11 @@ class ChassisControlObject(DbusProperties, DbusObjectManager):
bus.add_signal_receiver(self.SystemStateHandler,
signal_name="GotoSystemState")
-
def getInterface(self, name):
o = self.dbus_objects[name]
obj = bus.get_object(o['bus_name'], o['object_name'], introspect=False)
return dbus.Interface(obj, o['interface_name'])
-
@dbus.service.method(DBUS_NAME,
in_signature='', out_signature='')
def setIdentify(self):
@@ -152,7 +150,7 @@ class ChassisControlObject(DbusProperties, DbusObjectManager):
def reboot(self):
print "Rebooting"
if self.getPowerState() == POWER_OFF:
- self.powerOn();
+ self.powerOn()
else:
self.Set(DBUS_NAME, "reboot", 1)
self.powerOff()
@@ -163,7 +161,7 @@ class ChassisControlObject(DbusProperties, DbusObjectManager):
def softReboot(self):
print "Soft Rebooting"
if self.getPowerState() == POWER_OFF:
- self.powerOn();
+ self.powerOn()
else:
self.Set(DBUS_NAME, "reboot", 1)
self.softPowerOff()
@@ -178,8 +176,7 @@ class ChassisControlObject(DbusProperties, DbusObjectManager):
## Signal handler
def SystemStateHandler(self, state_name):
- if (
- state_name == "HOST_POWERED_OFF" or state_name == "HOST_POWERED_ON"):
+ if state_name in ["HOST_POWERED_OFF", "HOST_POWERED_ON"]:
intf = self.getInterface('settings')
intf.Set("org.openbmc.settings.Host", "system_state", state_name)
@@ -193,14 +190,14 @@ class ChassisControlObject(DbusProperties, DbusObjectManager):
if state == POWER_OFF:
self.powerOn()
elif state == POWER_ON:
- self.softPowerOff();
+ self.softPowerOff()
def long_power_button_signal_handler(self):
print "Long-press button, hard power off"
- self.powerOff();
+ self.powerOff()
def softreset_button_signal_handler(self):
- self.softReboot();
+ self.softReboot()
def host_watchdog_signal_handler(self):
print "Watchdog Error, Hard Rebooting"
@@ -239,4 +236,3 @@ if __name__ == '__main__':
print "Running ChassisControlService"
mainloop.run()
-
OpenPOWER on IntegriCloud