summaryrefslogtreecommitdiffstats
path: root/doc
diff options
context:
space:
mode:
authorDavid Müller (ELSOFT AG) <d.mueller@elsoft.ch>2016-02-06 07:57:28 +0100
committerTom Rini <trini@konsulko.com>2016-02-08 10:24:17 -0500
commit0c2b6dffb7fcd6ef028020587a030b6bef154a0e (patch)
tree68ce7b012597275cfa72b25016cb74a4cd7d68aa /doc
parent5a6f68d4963dcd7c7ffc8876ed6e18978cf4a03a (diff)
downloadtalos-obmc-uboot-0c2b6dffb7fcd6ef028020587a030b6bef154a0e.tar.gz
talos-obmc-uboot-0c2b6dffb7fcd6ef028020587a030b6bef154a0e.zip
doc: Remove any reference to CONFIG_MODEM_SUPPORT, CONFIG_CMD_HWFLOW, CONFIG_HWFLOW and friends from the documentation.
Signed-off-by: David Müller <d.mueller@elsoft.ch>
Diffstat (limited to 'doc')
-rw-r--r--doc/README.Modem72
1 files changed, 0 insertions, 72 deletions
diff --git a/doc/README.Modem b/doc/README.Modem
deleted file mode 100644
index 1613c11cad..0000000000
--- a/doc/README.Modem
+++ /dev/null
@@ -1,72 +0,0 @@
-How to configure modem support in U-Boot :
-
-1. Define modem initialization strings:
----------------------------------------
-
-The modem initialization strings have following format:
-
- mdm_init1=<AT-command>
- mdm_init2=<AT-command>
- ...
-
-Turning off modem verbose responses with ATV0 or ATQ1 is not allowed;
-U-Boot analyzes only verbose (not numeric) result codes. Modem local
-command echo can be turned off (ATE0).
-
-2. RTS/CTS hardware flow control:
----------------------------------
-
-You may wish to enable RTS/CTS hardware flow control, if the board's
-UART driver supports it (see CONFIG_HWFLOW compile-time flag in
-config/<board>.h). This is controlled by the 'mdm_flow_control'
-environment variable:
-
- 'mdm_flow_control=rts/cts' - to enable RTS/CTS flow control.
- 'mdm_flow_control=none ' - to disable.
-
-
-The following are the examples using a Rockwell OEM modem
-configuration:
-
-SAMSUNG # setenv mdm_init1 ATZ - reset the modem to
- the factory defaults.
-SAMSUNG # setenv mdm_init2 ATS0=1 - set modem into
- answer mode.
-SAMSUNG # setenv mdm_flow_control rts/cts - enable serial port
- flow control
-SAMSUNG # saveenv
-
-The example above initializes modem into answer mode to wait for the
-incoming call. RTS/CTS flow control is enabled for the serial port.
-(The RTS/CTS flow control is enabled by default on the modem).
-
-
-SAMSUNG # setenv mdm_init1 ATZ
-SAMSUNG # setenv mdm_init2 ATS39=0+IFC=0,0 - disable modem
- RTS/CTS flow control
-SAMSUNG # setenv mdm_init3 ATDT1643973 - dial out the number
-SAMSUNG # setenv mdm_flow_control none
-SAMSUNG # saveenv
-
-The example above initializes modem to dial-up connection on the
-number 1643973. Flow control is disabled.
-
-Note that flow control must be turned both off or both on for the
-board serial port and for the modem.
-
-
-If the connection was set up successfully, the U-Boot prompt appears
-on the terminal console. If not (U-Boot modem was configured for
-originating the call and connection was not established) - the board
-should be reset for another dial-up try.
-
-
-Note on the SMDK2400 board:
----------------------------
-
-Since the board serial ports does not have DTR signal wired, modem
-should be told to ignore port DTR setting prior to connection to the
-SMDK board, and this setting should be stored in modem NVRAM. For the
-Rockwell OEM modem this can to be done with the following command:
-
-AT&D0&W
OpenPOWER on IntegriCloud