summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorRaptor Engineering Development Team <support@raptorengineering.com>2018-01-25 04:14:48 -0600
committerRaptor Engineering Development Team <support@raptorengineering.com>2019-04-19 11:32:29 +0000
commitcc116ad0d001868a123d10732506ffd7c84a398b (patch)
tree5e248857141e97326a138f2ff9cdc034d3026555
parent0a7d837efe79ff442e6cb952eca0328e22324422 (diff)
downloadtalos-obmc-linux-cc116ad0d001868a123d10732506ffd7c84a398b.tar.gz
talos-obmc-linux-cc116ad0d001868a123d10732506ffd7c84a398b.zip
Update MAX31785 setings on Talos systems
Enable faster fan ramp up/down to avoid overshoot / fan speed oscillations Disable unnecessary temperature sensor watchdog
-rw-r--r--arch/arm/boot/dts/aspeed-bmc-opp-talos.dts18
1 files changed, 12 insertions, 6 deletions
diff --git a/arch/arm/boot/dts/aspeed-bmc-opp-talos.dts b/arch/arm/boot/dts/aspeed-bmc-opp-talos.dts
index 48e080e8eac1..851cc8d04615 100644
--- a/arch/arm/boot/dts/aspeed-bmc-opp-talos.dts
+++ b/arch/arm/boot/dts/aspeed-bmc-opp-talos.dts
@@ -253,7 +253,8 @@
maxim,fan-pwm-freq = <25000>;
maxim,fan-no-watchdog;
maxim,fan-no-fault-ramp;
- maxim,fan-ramp = <2>;
+ maxim,tmp-no-fault-ramp;
+ maxim,fan-ramp = <5>;
maxim,fan-fault-pin-mon;
};
@@ -267,7 +268,8 @@
maxim,fan-pwm-freq = <25000>;
maxim,fan-no-watchdog;
maxim,fan-no-fault-ramp;
- maxim,fan-ramp = <2>;
+ maxim,tmp-no-fault-ramp;
+ maxim,fan-ramp = <5>;
maxim,fan-fault-pin-mon;
};
@@ -281,7 +283,8 @@
maxim,fan-pwm-freq = <25000>;
maxim,fan-no-watchdog;
maxim,fan-no-fault-ramp;
- maxim,fan-ramp = <2>;
+ maxim,tmp-no-fault-ramp;
+ maxim,fan-ramp = <5>;
maxim,fan-fault-pin-mon;
};
@@ -295,7 +298,8 @@
maxim,fan-pwm-freq = <25000>;
maxim,fan-no-watchdog;
maxim,fan-no-fault-ramp;
- maxim,fan-ramp = <2>;
+ maxim,tmp-no-fault-ramp;
+ maxim,fan-ramp = <5>;
maxim,fan-fault-pin-mon;
};
@@ -309,7 +313,8 @@
maxim,fan-pwm-freq = <25000>;
maxim,fan-no-watchdog;
maxim,fan-no-fault-ramp;
- maxim,fan-ramp = <2>;
+ maxim,tmp-no-fault-ramp;
+ maxim,fan-ramp = <5>;
maxim,fan-fault-pin-mon;
};
@@ -323,7 +328,8 @@
maxim,fan-pwm-freq = <25000>;
maxim,fan-no-watchdog;
maxim,fan-no-fault-ramp;
- maxim,fan-ramp = <2>;
+ maxim,tmp-no-fault-ramp;
+ maxim,fan-ramp = <5>;
maxim,fan-fault-pin-mon;
};
};
OpenPOWER on IntegriCloud