diff options
author | Przemo Firszt <przemo@firszt.eu> | 2013-06-29 10:57:13 +0100 |
---|---|---|
committer | Jiri Kosina <jkosina@suse.cz> | 2013-07-04 15:04:47 +0200 |
commit | 9d157624035214793c6d06b0512c6ab1a7b39e05 (patch) | |
tree | 1c697f35a68399d19a473696fe1d47407897775e | |
parent | 26e04462c8b78d079d3231396ec72d58a14f114b (diff) | |
download | talos-obmc-linux-9d157624035214793c6d06b0512c6ab1a7b39e05.tar.gz talos-obmc-linux-9d157624035214793c6d06b0512c6ab1a7b39e05.zip |
HID: wacom: Intuos4 battery charging changes
Intuos4 WL is separately reporting power supply and battery
charging status - now hid-wacom is using that information.
Previously hid-wacom was wrongly treating "battery charging" bit
as "power supply connected". Now it should report battery charging,
battery discharging, battery full and power supply status.
Intuos4 WL sends reports when is in use (obvious) and when unplugging
power supply. If means that if the device is being charged, but it's not
being used it will never report "battery full". The same problem happens
after the device has been connected, but it's not in use - the
battery/ac status will be incorrect. Currently there is no mechanism to
ask the device to send a report containing battery/ac status.
Signed-off-by: Przemo Firszt <przemo@firszt.eu>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
-rw-r--r-- | drivers/hid/hid-wacom.c | 14 |
1 files changed, 13 insertions, 1 deletions
diff --git a/drivers/hid/hid-wacom.c b/drivers/hid/hid-wacom.c index a4a8bb0da688..60c75dcbbdb8 100644 --- a/drivers/hid/hid-wacom.c +++ b/drivers/hid/hid-wacom.c @@ -46,6 +46,7 @@ struct wacom_data { __u8 battery_capacity; __u8 power_raw; __u8 ps_connected; + __u8 bat_charging; struct power_supply battery; struct power_supply ac; __u8 led_selector; @@ -62,6 +63,7 @@ static enum power_supply_property wacom_battery_props[] = { POWER_SUPPLY_PROP_PRESENT, POWER_SUPPLY_PROP_CAPACITY, POWER_SUPPLY_PROP_SCOPE, + POWER_SUPPLY_PROP_STATUS, }; static enum power_supply_property wacom_ac_props[] = { @@ -287,6 +289,15 @@ static int wacom_battery_get_property(struct power_supply *psy, case POWER_SUPPLY_PROP_CAPACITY: val->intval = wdata->battery_capacity; break; + case POWER_SUPPLY_PROP_STATUS: + if (wdata->bat_charging) + val->intval = POWER_SUPPLY_STATUS_CHARGING; + else + if (wdata->battery_capacity == 100 && wdata->ps_connected) + val->intval = POWER_SUPPLY_STATUS_FULL; + else + val->intval = POWER_SUPPLY_STATUS_DISCHARGING; + break; default: ret = -EINVAL; break; @@ -727,7 +738,8 @@ static int wacom_raw_event(struct hid_device *hdev, struct hid_report *report, if (power_raw != wdata->power_raw) { wdata->power_raw = power_raw; wdata->battery_capacity = batcap_i4[power_raw & 0x07]; - wdata->ps_connected = power_raw & 0x08; + wdata->bat_charging = (power_raw & 0x08) ? 1 : 0; + wdata->ps_connected = (power_raw & 0x10) ? 1 : 0; } break; |