| Commit message (Collapse) | Author | Age | Files | Lines |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
- use the present value of ATTR_EXT_VRM_STEPSIZE (used by PGPE for Pstate
movement) to step the the boot voltage setup during istep 8. This attribute
defaults to 50mV.
- Done only for rails attached via AVSBus
Key_Cronus_Test=PM_REGRESS
Change-Id: I63feb361323246c8b92f1e96dc41f8fc19bd0912
CQ: SW420343
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/55386
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Tested-by: HWSV CI <hwsv-ci+hostboot@us.ibm.com>
Tested-by: PPE CI <ppe-ci+hostboot@us.ibm.com>
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Hostboot CI <hostboot-ci+hostboot@us.ibm.com>
Tested-by: Cronus HW CI <cronushw-ci+hostboot@us.ibm.com>
Reviewed-by: RANGANATHPRASAD G. BRAHMASAMUDRA <prasadbgr@in.ibm.com>
Reviewed-by: Brian T. Vanderpool <vanderp@us.ibm.com>
Reviewed-by: Jennifer A. Stofer <stofer@us.ibm.com>
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/55395
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Key_Cronus_Test=PM_REGRESS
RTC:180824
Change-Id: I27e56b33ba8774e955afc289b392fa421faae9f7
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/48684
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Tested-by: Cronus HW CI <cronushw-ci+hostboot@us.ibm.com>
Tested-by: Hostboot CI <hostboot-ci+hostboot@us.ibm.com>
Reviewed-by: Michael S. Floyd <mfloyd@us.ibm.com>
Reviewed-by: Prem Shanker Jha <premjha2@in.ibm.com>
Reviewed-by: Jennifer A. Stofer <stofer@us.ibm.com>
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/48687
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Change-Id: Ic67241ad192f82c43a4e5f2af8cab6f945a4dc35
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/46210
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: PPE CI <ppe-ci+hostboot@us.ibm.com>
Tested-by: Hostboot CI <hostboot-ci+hostboot@us.ibm.com>
Reviewed-by: Juan R. Medina <jrmedina@us.ibm.com>
Reviewed-by: Gregory S. Still <stillgs@us.ibm.com>
Reviewed-by: Jennifer A. Stofer <stofer@us.ibm.com>
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/46216
Reviewed-by: Hostboot Team <hostboot@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
- Updated dpll fmult setting code
- Updated review comments
- compute using biased freq values
- rebased
- updated safe mode values to gppb and oppb
- updated review comments
Change-Id: Ia08ac464d67be4608f3c293e083135a9cf65aaec
RTC:175533
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/44148
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: PPE CI <ppe-ci+hostboot@us.ibm.com>
Tested-by: Hostboot CI <hostboot-ci+hostboot@us.ibm.com>
Reviewed-by: Thi N. Tran <thi@us.ibm.com>
Reviewed-by: Juan R. Medina <jrmedina@us.ibm.com>
Reviewed-by: Gregory S. Still <stillgs@us.ibm.com>
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/44153
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
| |
Change-Id: I25a782f6f8af801beb35f541f6076c482b78bf8e
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/27920
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Reviewed-by: Matthew A. Ploetz <maploetz@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
This hwp is called at 2 different points during the IPL and
we do not want to reset default values if we have already done
it once.
Change-Id: Ia621802762b7fc79cedb1f8609477936e2c2cec6
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/26254
Tested-by: Jenkins Server
Tested-by: PPE CI
Reviewed-by: Andrew J. Geissler <andrewg@us.ibm.com>
Tested-by: Hostboot CI
Reviewed-by: Andres A. Lugo-Reyes <aalugore@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
Reviewed-by: Jennifer A. Stofer <stofer@us.ibm.com>
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/26267
Tested-by: FSP CI Jenkins
|
|
Change-Id: I1ec8f5d5b815b7f153d31a77e7239ff964fde556
Original-Change-Id: I923c0d7da9e825dbbb4a111648fc3457da22d572
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/20613
Tested-by: Jenkins Server
Tested-by: PPE CI
Tested-by: Hostboot CI
Reviewed-by: Jennifer A. Stofer <stofer@us.ibm.com>
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/25672
Tested-by: FSP CI Jenkins
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
|