summaryrefslogtreecommitdiffstats
path: root/src/usr/hwpf/hwp/dram_training/memory_mss_termination_control.xml
diff options
context:
space:
mode:
authorDan Crowell <dcrowell@us.ibm.com>2016-04-08 21:03:51 -0500
committerStephen Cprek <smcprek@us.ibm.com>2016-04-21 13:51:32 -0500
commit76f1c48130a060fbe83c851fce2474c17b2df9b2 (patch)
treee258515dcbdab5817603c9d290befe2324df7d59 /src/usr/hwpf/hwp/dram_training/memory_mss_termination_control.xml
parent3967f43b9478d7e6b58180dd0b331e61412997cd (diff)
downloadtalos-hostboot-76f1c48130a060fbe83c851fce2474c17b2df9b2.tar.gz
talos-hostboot-76f1c48130a060fbe83c851fce2474c17b2df9b2.zip
Removing some more old fapi1 and hwp code
Deleted all of the old fapi1 code Moved potentially reuseable occ code to a new dir Deleted a variety of p8 hwp files Change-Id: I8b6ab72fef3f1413d919bdd21bc88f2c4f59c5c3 RTC: 146345 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/23075 Tested-by: Jenkins Server Tested-by: FSP CI Jenkins Reviewed-by: Matt Derksen <v2cibmd@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
Diffstat (limited to 'src/usr/hwpf/hwp/dram_training/memory_mss_termination_control.xml')
-rw-r--r--src/usr/hwpf/hwp/dram_training/memory_mss_termination_control.xml252
1 files changed, 0 insertions, 252 deletions
diff --git a/src/usr/hwpf/hwp/dram_training/memory_mss_termination_control.xml b/src/usr/hwpf/hwp/dram_training/memory_mss_termination_control.xml
deleted file mode 100644
index a0f5eb72a..000000000
--- a/src/usr/hwpf/hwp/dram_training/memory_mss_termination_control.xml
+++ /dev/null
@@ -1,252 +0,0 @@
-<!-- IBM_PROLOG_BEGIN_TAG -->
-<!-- This is an automatically generated prolog. -->
-<!-- -->
-<!-- $Source: src/usr/hwpf/hwp/dram_training/memory_mss_termination_control.xml $ -->
-<!-- -->
-<!-- OpenPOWER HostBoot Project -->
-<!-- -->
-<!-- COPYRIGHT International Business Machines Corp. 2013,2014 -->
-<!-- -->
-<!-- Licensed under the Apache License, Version 2.0 (the "License"); -->
-<!-- you may not use this file except in compliance with the License. -->
-<!-- You may obtain a copy of the License at -->
-<!-- -->
-<!-- http://www.apache.org/licenses/LICENSE-2.0 -->
-<!-- -->
-<!-- Unless required by applicable law or agreed to in writing, software -->
-<!-- distributed under the License is distributed on an "AS IS" BASIS, -->
-<!-- WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or -->
-<!-- implied. See the License for the specific language governing -->
-<!-- permissions and limitations under the License. -->
-<!-- -->
-<!-- IBM_PROLOG_END_TAG -->
-
-<hwpErrors>
-<!-- $Id: memory_mss_termination_control.xml,v 1.4 2014/01/31 13:42:23 sasethur Exp $ -->
-<!-- For file ../../ipl/fapi/mss_termination_control.C -->
-<!-- // *! OWNER NAME : Saravanan Sethuraman email ID:saravanans@in.ibm.com -->
-<!-- // *! BACKUP NAME: Menlo Wuu email ID:menlowuu@us.ibm.com -->
-
-<hwpError>
- <rc>RC_CONFIG_DRV_IMP_INVALID_INPUT</rc>
- <description>
- The config_drv_imp utility function received a bad parameter
- </description>
- <ffdc>PORT_PARAM</ffdc>
- <callout>
- <procedure>CODE</procedure>
- <priority>HIGH</priority>
- </callout>
-</hwpError>
-
-<hwpError>
- <rc>RC_CONFIG_RCV_IMP_INVALID_INPUT</rc>
- <description>
- The config_rcv_imp utility function received a bad parameter
- </description>
- <ffdc>PORT_PARAM</ffdc>
- <callout>
- <procedure>CODE</procedure>
- <priority>HIGH</priority>
- </callout>
-</hwpError>
-
-<hwpError>
- <rc>RC_CONFIG_SLEW_RATE_INVALID_INPUT</rc>
- <description>
- The config_slew_rate utility function received a bad parameter
- </description>
- <ffdc>PORT_PARAM</ffdc>
- <ffdc>SLEW_TYPE_PARAM</ffdc>
- <ffdc>SLEW_IMP_PARAM</ffdc>
- <ffdc>SLEW_RATE_PARAM</ffdc>
- <callout>
- <procedure>CODE</procedure>
- <priority>HIGH</priority>
- </callout>
-</hwpError>
-
-<hwpError>
- <rc>RC_CONFIG_WR_DRAM_VREF_INVALID_INPUT</rc>
- <description>
- The config_wr_dram_vref utility function received a bad parameter
- </description>
- <ffdc>PORT_PARAM</ffdc>
- <callout>
- <procedure>CODE</procedure>
- <priority>HIGH</priority>
- </callout>
-</hwpError>
-
-<hwpError>
- <rc>RC_CONFIG_RD_CEN_VREF_INVALID_INPUT</rc>
- <description>
- The config_rd_cen_vref utility function received a bad parameter
- </description>
- <ffdc>PORT_PARAM</ffdc>
- <callout>
- <procedure>CODE</procedure>
- <priority>HIGH</priority>
- </callout>
-</hwpError>
-
-<hwpError>
- <rc>RC_MSS_SLEW_CAL_INVALID_DRAM_GEN</rc>
- <description>
- mss_slew_cal found an invalid DRAM type in ATTR_EFF_DRAM_GEN (not DDR3/4)
- </description>
- <ffdc>DRAM_GEN</ffdc>
- <callout>
- <procedure>CODE</procedure>
- <priority>HIGH</priority>
- </callout>
-</hwpError>
-
-<hwpError>
- <rc>RC_MSS_SLEW_CAL_INVALID_FREQ</rc>
- <description>
- mss_slew_cal found a zero frequency in ATTR_MSS_FREQ
- </description>
- <callout>
- <procedure>CODE</procedure>
- <priority>HIGH</priority>
- </callout>
-</hwpError>
-
-<registerFfdc>
- <id>REG_FFDC_MSS_SLEW_CAL_FAILURE_PORT0</id>
- <scomRegister>DPHY01_DDRPHY_ADR_IO_SLEW_CTL_VALUE_P0_ADR0_0x8000401A0301143F</scomRegister>
- <scomRegister>DPHY01_DDRPHY_ADR_IO_SLEW_CTL_VALUE_P0_ADR1_0x8000441A0301143F</scomRegister>
- <scomRegister>DPHY01_DDRPHY_ADR_IO_SLEW_CTL_VALUE_P0_ADR2_0x8000481A0301143F</scomRegister>
- <scomRegister>DPHY01_DDRPHY_ADR_IO_SLEW_CTL_VALUE_P0_ADR3_0x80004C1A0301143F</scomRegister>
- <scomRegister>DPHY01_DDRPHY_DP18_IO_TX_CONFIG0_P0_0_0x800000750301143F</scomRegister>
- <scomRegister>DPHY01_DDRPHY_DP18_IO_TX_CONFIG0_P0_1_0x800004750301143F</scomRegister>
- <scomRegister>DPHY01_DDRPHY_DP18_IO_TX_CONFIG0_P0_2_0x800008750301143F</scomRegister>
- <scomRegister>DPHY01_DDRPHY_DP18_IO_TX_CONFIG0_P0_3_0x80000C750301143F</scomRegister>
- <scomRegister>DPHY01_DDRPHY_DP18_IO_TX_CONFIG0_P0_4_0x800010750301143F</scomRegister>
-</registerFfdc>
-
-<registerFfdc>
- <id>REG_FFDC_MSS_SLEW_CAL_FAILURE_PORT1</id>
- <scomRegister>DPHY01_DDRPHY_ADR_IO_SLEW_CTL_VALUE_P1_ADR0_0x8001401A0301143F</scomRegister>
- <scomRegister>DPHY01_DDRPHY_ADR_IO_SLEW_CTL_VALUE_P1_ADR1_0x8001441A0301143F</scomRegister>
- <scomRegister>DPHY01_DDRPHY_ADR_IO_SLEW_CTL_VALUE_P1_ADR2_0x8001481A0301143F</scomRegister>
- <scomRegister>DPHY01_DDRPHY_ADR_IO_SLEW_CTL_VALUE_P1_ADR3_0x80014C1A0301143F</scomRegister>
- <scomRegister>DPHY01_DDRPHY_DP18_IO_TX_CONFIG0_P1_0_0x800100750301143F</scomRegister>
- <scomRegister>DPHY01_DDRPHY_DP18_IO_TX_CONFIG0_P1_1_0x800104750301143F</scomRegister>
- <scomRegister>DPHY01_DDRPHY_DP18_IO_TX_CONFIG0_P1_2_0x800108750301143F</scomRegister>
- <scomRegister>DPHY01_DDRPHY_DP18_IO_TX_CONFIG0_P1_3_0x80010C750301143F</scomRegister>
- <scomRegister>DPHY01_DDRPHY_DP18_IO_TX_CONFIG0_P1_4_0x800110750301143F</scomRegister>
-</registerFfdc>
-
-<hwpError>
- <rc>RC_MSS_SLEW_CAL_TIMEOUT_PORT0</rc>
- <description>
- mss_slew_cal found slew calibration timeout on MBA port 0
- </description>
- <ffdc>DATA_ADR</ffdc>
- <ffdc>IMP</ffdc>
- <ffdc>SLEW</ffdc>
- <ffdc>STAT_REG</ffdc>
- <collectRegisterFfdc>
- <id>REG_FFDC_MSS_SLEW_CAL_FAILURE_PORT0</id>
- <target>MBA_IN_ERROR</target>
- </collectRegisterFfdc>
- <callout>
- <target>MBA_IN_ERROR</target>
- <priority>HIGH</priority>
- </callout>
- <deconfigure>
- <target>MBA_IN_ERROR</target>
- </deconfigure>
- <gard>
- <target>MBA_IN_ERROR</target>
- </gard>
-</hwpError>
-
-<hwpError>
- <rc>RC_MSS_SLEW_CAL_TIMEOUT_PORT1</rc>
- <description>
- mss_slew_cal found slew calibration timeout on MBA port 1
- </description>
- <ffdc>DATA_ADR</ffdc>
- <ffdc>IMP</ffdc>
- <ffdc>SLEW</ffdc>
- <ffdc>STAT_REG</ffdc>
- <collectRegisterFfdc>
- <id>REG_FFDC_MSS_SLEW_CAL_FAILURE_PORT1</id>
- <target>MBA_IN_ERROR</target>
- </collectRegisterFfdc>
- <callout>
- <target>MBA_IN_ERROR</target>
- <priority>HIGH</priority>
- </callout>
- <deconfigure>
- <target>MBA_IN_ERROR</target>
- </deconfigure>
- <gard>
- <target>MBA_IN_ERROR</target>
- </gard>
-</hwpError>
-
-<hwpError>
- <rc>RC_MSS_SLEW_CAL_ERROR_PORT0</rc>
- <description>
- mss_slew_cal found slew calibration error on MBA port 0
- </description>
- <ffdc>DATA_ADR</ffdc>
- <ffdc>IMP</ffdc>
- <ffdc>SLEW</ffdc>
- <ffdc>STAT_REG</ffdc>
- <collectRegisterFfdc>
- <id>REG_FFDC_MSS_SLEW_CAL_FAILURE_PORT0</id>
- <target>MBA_IN_ERROR</target>
- </collectRegisterFfdc>
- <callout>
- <target>MBA_IN_ERROR</target>
- <priority>HIGH</priority>
- </callout>
- <deconfigure>
- <target>MBA_IN_ERROR</target>
- </deconfigure>
- <gard>
- <target>MBA_IN_ERROR</target>
- </gard>
-</hwpError>
-
-<hwpError>
- <rc>RC_MSS_SLEW_CAL_ERROR_PORT1</rc>
- <description>
- mss_slew_cal found slew calibration error on MBA port 1
- </description>
- <ffdc>DATA_ADR</ffdc>
- <ffdc>IMP</ffdc>
- <ffdc>SLEW</ffdc>
- <ffdc>STAT_REG</ffdc>
- <collectRegisterFfdc>
- <id>REG_FFDC_MSS_SLEW_CAL_FAILURE_PORT1</id>
- <target>MBA_IN_ERROR</target>
- </collectRegisterFfdc>
- <callout>
- <target>MBA_IN_ERROR</target>
- <priority>HIGH</priority>
- </callout>
- <deconfigure>
- <target>MBA_IN_ERROR</target>
- </deconfigure>
- <gard>
- <target>MBA_IN_ERROR</target>
- </gard>
-</hwpError>
-
-<hwpError>
- <rc>RC_MSS_IMP_INPUT_ERROR</rc>
- <!-- TODO Remove when all HWPs using it are using their own Error XML file -->
- <description>Impedance is invalid for driver/receiver type.</description>
- <callout>
- <procedure>CODE</procedure>
- <priority>HIGH</priority>
- </callout>
-</hwpError>
-
-</hwpErrors>
OpenPOWER on IntegriCloud