docs: Cleanup of Design Doc
The google-drive -> markdown added those reference points and they are
not needed and show up. This removes them.
Change-Id: If7ab88a08b048e78b4cd8a2159e7e56180bd55a3
Signed-off-by: Patrick Venture <venture@google.com>
| -rw-r--r-- | README.md | 42 |
1 files changed, 21 insertions, 21 deletions
@@ -2,7 +2,7 @@ [TOC] -## Objective {#objective} +## Objective Develop a tray level fan control system that will use exhaust temperature and other machine temperature information to control fan speeds in order to keep @@ -11,7 +11,7 @@ machines within acceptable operating conditions. Effectively porting the Chromium EC thermal code to run on the BMC and use the OpenBMC dbus namespace and IPMI commands. -## Background {#background} +## Background Recent server systems come with a general secondary processing system attached for the purpose of monitoring and control, generally referred to as a BMC[^2]. @@ -33,7 +33,7 @@ IPMI allows for OEM commands to provide custom information flow or system control with a BMC. OEM commands are already lined up for certain other accesses routed through the BMC, and can be upstreamed for others to use. -## Overview {#overview} +## Overview The BMC will run a daemon that controls the fans by pre-defined zones. The application will use thermal control, such that each defined zone is kept @@ -50,7 +50,7 @@ should be provided in case of failure or other unknown situation. The system will run a control loop for each zone with the attempt to maintain the temperature within that zone within the margin for the devices specified. -## Detailed Design {#detailed-design} +## Detailed Design The software will run as a multi-threaded daemon that runs a control loop for each zone, and has a master thread which listens for dbus messages. Each zone @@ -62,7 +62,7 @@ will require at least one fan that it exclusively controls, however, zones can In this figure the communications channels between swampd and ipmid and phosphor-hwmon are laid out. -### OpenBMC Upstream {#openbmc-upstream} +### OpenBMC Upstream To be upstreamed to OpenBMC for use on open-power systems, we need to follow the OpenBMC code style specification[^9] and leverage the dbus framework for reading @@ -79,7 +79,7 @@ controlling the fans only via specifying the RPM target, whereas the driver we're using for Quanta-Q71l (the first system) only allows writing PWM. This can be controlled either directly or via dbus. -### Zone Specification {#zone-specification} +### Zone Specification A configuration file will need to exist for each board, likely in YAML[^12]. Similar information will also be necessary for gsys, such that it knows what @@ -96,7 +96,7 @@ factor and described in the configuration. The internal thermometers specified will be read via sysfs. -#### A proposed configuration file: {#a-proposed-configuration-file} +#### A proposed configuration file: ``` {ZONEID}: @@ -140,12 +140,12 @@ The internal thermometers specified will be read via sysfs. slew_positive: 0 ``` -### Chassis Delta {#chassis-delta} +### Chassis Delta Due to data center requirements, the delta between the outgoing air temperature and the environmental air temperature must be no greater than 15C. -### IPMI Command Specification {#ipmi-command-specification} +### IPMI Command Specification Gsys needs the ability to send to the BMC, the margin information on the devices that it knows how to read that the BMC cannot. There is no command in IPMI that @@ -154,7 +154,7 @@ currently supports this use-case, therefore it will be added as an OEM command. The state of the BMC readable temperature sensors can be read through normal IPMI commands and is already supported. -#### OEM Set Control {#oem-set-control} +#### OEM Set Control Gsys needs to be able to set the control of the thermal system to either automatic or manual. When manual, the daemon will effectively wait to be told to @@ -185,7 +185,7 @@ Byte | Purpose | Value `04` | `padding` | `0x00` `07` | `Mode` | `If Set, Value 1 == Manual Mode, 0 == Automatic Mode` -#### OEM Get Failsafe Mode {#oem-get-failsafe-mode} +#### OEM Get Failsafe Mode Gbmctool needs to be able to read back whether a zone is in failsafe mode. This setting is read-only because it's dynamically determined within Swampd per zone. @@ -209,7 +209,7 @@ Byte | Purpose | Value `04` | `padding` | `0x00` `07` | `failsafe` | `1 == in Failsafe Mode, 0 not in failsafe mode` -#### Set Sensor Value {#set-sensor-value} +#### Set Sensor Value Gsys needs to update the thermal controller with information not necessarily available to the BMC. This will comprise of a list of temperature (or margin?) @@ -217,17 +217,17 @@ sensors that are updated by the set sensor command. Because they don't represent real sensors in the system, the set sensor handler can simply broadcast the update as a properties update on dbus when it receives the command over IPMI. -#### Set Fan PWM {#set-fan-pwm} +#### Set Fan PWM Gsys can override a specific fan's PWM when we implement the set sensor IPMI command pathway. -#### Get Fan Tach {#get-fan-tach} +#### Get Fan Tach Gsys can read fan_tach through the normal IPMI interface presently exported for sensors. -### Sensor Update Loop {#sensor-update-loop} +### Sensor Update Loop The plan is to listen for fan_tach updates for each fan in a background thread. This will receive an update from phosphor-hwmon each time it updates any sensor @@ -238,7 +238,7 @@ second. We'll be updating phosphor-hwmon to sleep for a shorter period -- how short though is still TBD. We'll also be updating phosphor-hwmon to support pwm as a target. -### Thermal Control Loops {#thermal-control-loops} +### Thermal Control Loops Each zone will require a control loop that monitors the associated thermals and controls the fan(s). The EC PID loop is designed to hit the fans 10 times per @@ -249,7 +249,7 @@ the system to its knees -- in that all CPU cycles would be spent reading the fans. TBD on how frequently we'll be reading the fan sensors and the impact this will have. -### Main Thread {#main-thread} +### Main Thread The main thread will manage the other threads, and process the initial configuration files. It will also register a dbus handler for the OEM message. @@ -265,7 +265,7 @@ EXTRA_OEMAKE_append_YOUR_MACHINE = " CXXFLAGS='${CXXFLAGS} -D__TUNING_LOGGING__' To the recipe. -## Project Information {#project-information} +## Project Information This project is designed to be a daemon running within the OpenBMC environment. It will use a well-defined configuration file to control the temperature of the @@ -273,18 +273,18 @@ tray components to keep them within operating conditions. It will require coordinate with gsys and OpenBMC. Providing a host-side service upstream to talk to the BMC is beyond the scope of this project. -## Security Considerations {#security-considerations} +## Security Considerations A rogue client on the host could send invalid thermal information causing physical damage to the system. There will be an effort to sanity check all input from gsys to alleviate this concern. -## Privacy Considerations {#privacy-considerations} +## Privacy Considerations This device holds no user data, however, you could profile the types of jobs executed on the server by watching its temperatures. -## Testing Plan {#testing-plan} +## Testing Plan Testing individual code logic will be handled through unit-tests, however some pieces of code rely on abstractions such that we can swap out dbus with |