summaryrefslogtreecommitdiffstats
path: root/pychassisctl/chassis_control.py
blob: 7f1419581e501cb68859ac4373e5de7d6277e545 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
#!/usr/bin/python -u

import sys
import uuid
import gobject
import dbus
import dbus.service
import dbus.mainloop.glib
from obmc.dbuslib.bindings import get_dbus, DbusProperties, DbusObjectManager

DBUS_NAME = 'org.openbmc.control.Chassis'
OBJ_NAME = '/org/openbmc/control/chassis0'
CONTROL_INTF = 'org.openbmc.Control'

MACHINE_ID = '/etc/machine-id'

POWER_OFF = 0
POWER_ON = 1

BOOTED = 100


class ChassisControlObject(DbusProperties, DbusObjectManager):
    def getUuid(self):
        uuid = "";
        try:
            with open(MACHINE_ID) as f:
                data = f.readline().rstrip('\n')
                if (len(data) == 32):
                    uuid = data
                else:
                    print "ERROR:  UUID is not formatted correctly: " + data
        except:
            print "ERROR: Unable to open uuid file: " + MACHINE_ID

        return uuid

    def __init__(self, bus, name):
        self.dbus_objects = {}
        DbusProperties.__init__(self)
        DbusObjectManager.__init__(self)
        dbus.service.Object.__init__(self, bus, name)
        ## load utilized objects
        self.dbus_objects = {
            'power_control': {
                'bus_name': 'org.openbmc.control.Power',
                'object_name': '/org/openbmc/control/power0',
                'interface_name': 'org.openbmc.control.Power'
            },
            'identify_led': {
                'bus_name': 'org.openbmc.control.led',
                'object_name': '/org/openbmc/control/led/identify',
                'interface_name': 'org.openbmc.Led'
            },
            'watchdog': {
                'bus_name': 'org.openbmc.watchdog.Host',
                'object_name': '/org/openbmc/watchdog/host0',
                'interface_name': 'org.openbmc.Watchdog'
            },
            'host_services': {
                'bus_name': 'org.openbmc.HostServices',
                'object_name': '/org/openbmc/HostServices',
                'interface_name': 'org.openbmc.HostServices'
            },
            'settings': {
                'bus_name': 'org.openbmc.settings.Host',
                'object_name': '/org/openbmc/settings/host0',
                'interface_name': 'org.freedesktop.DBus.Properties'
            },
            'host_control': {
                'bus_name': 'org.openbmc.control.Host',
                'object_name': '/org/openbmc/control/host0',
                'interface_name': 'org.openbmc.control.Host'
            },
        }

        # uuid
        self.Set(DBUS_NAME, "uuid", self.getUuid())
        self.Set(DBUS_NAME, "reboot", 0)

        bus.add_signal_receiver(self.power_button_signal_handler,
                                dbus_interface="org.openbmc.Button",
                                signal_name="Released",
                                path="/org/openbmc/buttons/power0")
        bus.add_signal_receiver(self.long_power_button_signal_handler,
                                dbus_interface="org.openbmc.Button",
                                signal_name="PressedLong",
                                path="/org/openbmc/buttons/power0")
        bus.add_signal_receiver(self.softreset_button_signal_handler,
                                dbus_interface="org.openbmc.Button",
                                signal_name="Released",
                                path="/org/openbmc/buttons/reset0")

        bus.add_signal_receiver(self.host_watchdog_signal_handler,
                                dbus_interface="org.openbmc.Watchdog",
                                signal_name="WatchdogError")

        bus.add_signal_receiver(self.emergency_shutdown_signal_handler,
                                dbus_interface="org.openbmc.SensorThresholds",
                                signal_name="Emergency")

        bus.add_signal_receiver(self.SystemStateHandler,
                                signal_name="GotoSystemState")


    def getInterface(self, name):
        o = self.dbus_objects[name]
        obj = bus.get_object(o['bus_name'], o['object_name'], introspect=False)
        return dbus.Interface(obj, o['interface_name'])


    @dbus.service.method(DBUS_NAME,
                         in_signature='', out_signature='')
    def setIdentify(self):
        print "Turn on identify"
        intf = self.getInterface('identify_led')
        intf.setOn()
        return None

    @dbus.service.method(DBUS_NAME,
                         in_signature='', out_signature='')
    def clearIdentify(self):
        print "Turn on identify"
        intf = self.getInterface('identify_led')
        intf.setOff()
        return None

    @dbus.service.method(DBUS_NAME,
                         in_signature='', out_signature='')
    def powerOn(self):
        print "Turn on power and boot"
        self.Set(DBUS_NAME, "reboot", 0)
        if (self.getPowerState() == 0):
            intf = self.getInterface('power_control')
            intf.setPowerState(POWER_ON)

            # Determine if debug_mode is set.  If it is then we don't
            # want to start the watchdog since debug mode
            intfcontrol = self.getInterface('host_control')
            intfproperties = dbus.Interface(intfcontrol,
                                            "org.freedesktop.DBus.Properties")
            debug_mode = intfproperties.Get('org.openbmc.control.Host',
                                            'debug_mode')
            if(not debug_mode):
                intfwatchdog = self.getInterface('watchdog')
                # Start watchdog with 30s timeout per the OpenPower Host IPMI Spec
                #Once the host starts booting, it'll reset and refresh the timer
                intfwatchdog.set(30000)
                intfwatchdog.start()
            else:
                print "Debug mode is on, no watchdog"
        return None

    @dbus.service.method(DBUS_NAME,
                         in_signature='', out_signature='')
    def powerOff(self):
        print "Turn off power"
        intfwatchdog = self.getInterface('watchdog')
        intfwatchdog.stop()
        intf = self.getInterface('power_control')
        intf.setPowerState(POWER_OFF)
        return None

    @dbus.service.method(DBUS_NAME,
                         in_signature='', out_signature='')
    def softPowerOff(self):
        print "Soft off power"
        intf = self.getInterface('host_services')
        ## host services will call power off when ready
        intf.SoftPowerOff()
        return None

    @dbus.service.method(DBUS_NAME,
                         in_signature='', out_signature='')
    def reboot(self):
        print "Rebooting"
        if self.getPowerState() == POWER_OFF:
            self.powerOn();
        else:
            self.Set(DBUS_NAME, "reboot", 1)
            self.powerOff()
        return None

    @dbus.service.method(DBUS_NAME,
                         in_signature='', out_signature='')
    def softReboot(self):
        print "Soft Rebooting"
        if self.getPowerState() == POWER_OFF:
            self.powerOn();
        else:
            self.Set(DBUS_NAME, "reboot", 1)
            self.softPowerOff()
        return None

    @dbus.service.method(DBUS_NAME,
                         in_signature='', out_signature='i')
    def getPowerState(self):
        intf = self.getInterface('power_control')
        return intf.getPowerState()

    ## Signal handler

    def SystemStateHandler(self, state_name):
        if (
                state_name == "HOST_POWERED_OFF" or state_name == "HOST_POWERED_ON"):
            intf = self.getInterface('settings')
            intf.Set("org.openbmc.settings.Host", "system_state", state_name)

        if (state_name == "HOST_POWERED_OFF" and self.Get(DBUS_NAME,
                                                          "reboot") == 1):
            self.powerOn()

    def power_button_signal_handler(self):
        # toggle power, power-on / soft-power-off
        state = self.getPowerState()
        if state == POWER_OFF:
            self.powerOn()
        elif state == POWER_ON:
            self.softPowerOff();

    def long_power_button_signal_handler(self):
        print "Long-press button, hard power off"
        self.powerOff();

    def softreset_button_signal_handler(self):
        self.softReboot();

    def host_watchdog_signal_handler(self):
        print "Watchdog Error, Hard Rebooting"
        self.Set(DBUS_NAME, "reboot", 1)
        self.powerOff()

    def emergency_shutdown_signal_handler(self, message):
        print "Emergency Shutdown!"
        # Log an event.
        try:
            # Exception happens or not, we need to power off.
            obj = bus.get_object("org.openbmc.records.events",
                                 "/org/openbmc/records/events",
                                 introspect=False)
            intf = dbus.Interface(obj, "org.openbmc.recordlog")
            desc = message
            sev = "critical error"
            details = "Get emergency shutdown signal. Shutdown the host."
            debug = dbus.ByteArray("")
            intf.acceptBMCMessage(desc, sev, details, debug)
        except Exception as e:
            print "Emergency shutdown signal handler: log event error."
            print e
        self.powerOff()


if __name__ == '__main__':
    dbus.mainloop.glib.DBusGMainLoop(set_as_default=True)

    bus = get_dbus()
    obj = ChassisControlObject(bus, OBJ_NAME)
    mainloop = gobject.MainLoop()

    obj.unmask_signals()
    name = dbus.service.BusName(DBUS_NAME, bus)

    print "Running ChassisControlService"
    mainloop.run()

OpenPOWER on IntegriCloud