summaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon/adm1275
blob: 6a3a6476cf207891895441205e3c2a180f8c38cd (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
Kernel driver adm1275
=====================

Supported chips:
  * Analog Devices ADM1275
    Prefix: 'adm1275'
    Addresses scanned: -
    Datasheet: www.analog.com/static/imported-files/data_sheets/ADM1275.pdf

Author: Guenter Roeck <guenter.roeck@ericsson.com>


Description
-----------

This driver supports hardware montoring for Analog Devices ADM1275 Hot-Swap
Controller and Digital Power Monitor.

The ADM1275 is a hot-swap controller that allows a circuit board to be removed
from or inserted into a live backplane. It also features current and voltage
readback via an integrated 12-bit analog-to-digital converter (ADC), accessed
using a PMBus. interface.

The driver is a client driver to the core PMBus driver. Please see
Documentation/hwmon/pmbus for details on PMBus client drivers.


Usage Notes
-----------

This driver does not auto-detect devices. You will have to instantiate the
devices explicitly. Please see Documentation/i2c/instantiating-devices for
details.


Platform data support
---------------------

The driver supports standard PMBus driver platform data. Please see
Documentation/hwmon/pmbus for details.


Sysfs entries
-------------

The following attributes are supported. Limits are read-write; all other
attributes are read-only.

in1_label		"vin1" or "vout1" depending on chip variant and
			configuration.
in1_input		Measured voltage. From READ_VOUT register.
in1_min			Minumum Voltage. From VOUT_UV_WARN_LIMIT register.
in1_max			Maximum voltage. From VOUT_OV_WARN_LIMIT register.
in1_min_alarm		Voltage low alarm. From VOLTAGE_UV_WARNING status.
in1_max_alarm		Voltage high alarm. From VOLTAGE_OV_WARNING status.

curr1_label		"iout1"
curr1_input		Measured current. From READ_IOUT register.
curr1_max		Maximum current. From IOUT_OC_WARN_LIMIT register.
curr1_max_alarm		Current high alarm. From IOUT_OC_WARN_LIMIT register.
OpenPOWER on IntegriCloud