summaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon/w83781d
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/hwmon/w83781d')
-rw-r--r--Documentation/hwmon/w83781d19
1 files changed, 19 insertions, 0 deletions
diff --git a/Documentation/hwmon/w83781d b/Documentation/hwmon/w83781d
index e5459333ba68..ac155d8b0fef 100644
--- a/Documentation/hwmon/w83781d
+++ b/Documentation/hwmon/w83781d
@@ -123,6 +123,25 @@ When an alarm goes off, you can be warned by a beeping signal through
your computer speaker. It is possible to enable all beeping globally,
or only the beeping for some alarms.
+Individual alarm and beep bits:
+
+0x000001: in0
+0x000002: in1
+0x000004: in2
+0x000008: in3
+0x000010: temp1
+0x000020: temp2 (+temp3 on W83781D)
+0x000040: fan1
+0x000080: fan2
+0x000100: in4
+0x000200: in5
+0x000400: in6
+0x000800: fan3
+0x001000: chassis
+0x002000: temp3 (W83782D and W83627HF only)
+0x010000: in7 (W83782D and W83627HF only)
+0x020000: in8 (W83782D and W83627HF only)
+
If an alarm triggers, it will remain triggered until the hardware register
is read at least once. This means that the cause for the alarm may
already have disappeared! Note that in the current implementation, all
OpenPOWER on IntegriCloud