diff --git a/Documentation/ABI/testing/sysfs-bus-iio-timer-stm32 b/Documentation/ABI/testing/sysfs-bus-iio-timer-stm32 new file mode 100644 index 000000000000..6534a60037ff --- /dev/null +++ b/Documentation/ABI/testing/sysfs-bus-iio-timer-stm32 @@ -0,0 +1,29 @@ +What: /sys/bus/iio/devices/triggerX/master_mode_available +KernelVersion: 4.11 +Contact: benjamin.gaignard@st.com +Description: + Reading returns the list possible master modes which are: + - "reset" : The UG bit from the TIMx_EGR register is used as trigger output (TRGO). + - "enable" : The Counter Enable signal CNT_EN is used as trigger output. + - "update" : The update event is selected as trigger output. + For instance a master timer can then be used as a prescaler for a slave timer. + - "compare_pulse" : The trigger output send a positive pulse when the CC1IF flag is to be set. + - "OC1REF" : OC1REF signal is used as trigger output. + - "OC2REF" : OC2REF signal is used as trigger output. + - "OC3REF" : OC3REF signal is used as trigger output. + - "OC4REF" : OC4REF signal is used as trigger output. + +What: /sys/bus/iio/devices/triggerX/master_mode +KernelVersion: 4.11 +Contact: benjamin.gaignard@st.com +Description: + Reading returns the current master modes. + Writing set the master mode + +What: /sys/bus/iio/devices/triggerX/sampling_frequency +KernelVersion: 4.11 +Contact: benjamin.gaignard@st.com +Description: + Reading returns the current sampling frequency. + Writing an value different of 0 set and start sampling. + Writing 0 stop sampling. |