summaryrefslogtreecommitdiffstats
path: root/net/ipv6/ipcomp6.c
diff options
context:
space:
mode:
authorMariusz Bialonczyk <manio@skyboo.net>2016-03-29 18:41:38 +0200
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>2016-05-01 14:04:19 -0700
commitf704938c0ef1e3224e66b16d5b358f02cd351240 (patch)
tree4b3b7aad0c8d20bea8a682162ee66f2ae2525c36 /net/ipv6/ipcomp6.c
parenta8ab316ab12501908cc355fee6aff7065609f4e2 (diff)
downloadtalos-op-linux-f704938c0ef1e3224e66b16d5b358f02cd351240.tar.gz
talos-op-linux-f704938c0ef1e3224e66b16d5b358f02cd351240.zip
w1: enable active pullup for DS2482 by default
This commit enables the active pullup (APU bit) by default for the DS2482 1-Wire master. >From the DS2482 datasheet: "The APU bit controls whether an active pullup (controlled slew-rate transistor) or a passive pullup (Rwpu resistor) will be used to drive a 1-Wire line from low to high. When APU = 0, active pullup is disabled (resistor mode). Active Pullup should always be selected unless there is only a single slave on the 1-Wire line." According to the module author, Ben Gardner: "It doesn't look like active pullup would cause any hurt if there is only a single slave." And my tests with multiple and single slaves on 1-Wire bus confirms that. This active pullup can be manually disabled using the introduced module parameter: active_pullup = 0 Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Diffstat (limited to 'net/ipv6/ipcomp6.c')
0 files changed, 0 insertions, 0 deletions
OpenPOWER on IntegriCloud