summaryrefslogtreecommitdiffstats
path: root/drivers/tty/serial/crisv10.c
diff options
context:
space:
mode:
authorDaniel Vetter <daniel.vetter@ffwll.ch>2015-11-23 09:04:05 +0100
committerDaniel Vetter <daniel.vetter@ffwll.ch>2015-11-23 09:04:05 +0100
commit92907cbbef8625bb3998d1eb385fc88f23c97a3f (patch)
tree15626ff9287e37c3cb81c7286d6db5a7fd77c854 /drivers/tty/serial/crisv10.c
parent15fbfccfe92c62ae8d1ecc647c44157ed01ac02e (diff)
parent1ec218373b8ebda821aec00bb156a9c94fad9cd4 (diff)
downloadtalos-op-linux-92907cbbef8625bb3998d1eb385fc88f23c97a3f.tar.gz
talos-op-linux-92907cbbef8625bb3998d1eb385fc88f23c97a3f.zip
Merge tag 'v4.4-rc2' into drm-intel-next-queued
Linux 4.4-rc2 Backmerge to get at commit 1b0e3a049efe471c399674fd954500ce97438d30 Author: Imre Deak <imre.deak@intel.com> Date: Thu Nov 5 23:04:11 2015 +0200 drm/i915/skl: disable display side power well support for now so that we can proplery re-eanble skl power wells in -next. Conflicts are just adjacent lines changed, except for intel_fbdev.c where we need to interleave the changs. Nothing nefarious. Signed-off-by: Daniel Vetter <daniel.vetter@intel.com>
Diffstat (limited to 'drivers/tty/serial/crisv10.c')
-rw-r--r--drivers/tty/serial/crisv10.c34
1 files changed, 1 insertions, 33 deletions
diff --git a/drivers/tty/serial/crisv10.c b/drivers/tty/serial/crisv10.c
index 3e4470af5c50..f13f2ebd215b 100644
--- a/drivers/tty/serial/crisv10.c
+++ b/drivers/tty/serial/crisv10.c
@@ -3655,7 +3655,6 @@ rs_close(struct tty_struct *tty, struct file * filp)
wake_up_interruptible(&info->port.open_wait);
}
info->port.flags &= ~(ASYNC_NORMAL_ACTIVE|ASYNC_CLOSING);
- wake_up_interruptible(&info->port.close_wait);
local_irq_restore(flags);
/* port closed */
@@ -3759,23 +3758,6 @@ block_til_ready(struct tty_struct *tty, struct file * filp,
int do_clocal = 0;
/*
- * If the device is in the middle of being closed, then block
- * until it's done, and then try again.
- */
- if (info->port.flags & ASYNC_CLOSING) {
- wait_event_interruptible_tty(tty, info->port.close_wait,
- !(info->port.flags & ASYNC_CLOSING));
-#ifdef SERIAL_DO_RESTART
- if (info->port.flags & ASYNC_HUP_NOTIFY)
- return -EAGAIN;
- else
- return -ERESTARTSYS;
-#else
- return -EAGAIN;
-#endif
- }
-
- /*
* If non-blocking mode is set, or the port is not enabled,
* then make the check up front and then exit.
*/
@@ -3825,7 +3807,7 @@ block_til_ready(struct tty_struct *tty, struct file * filp,
#endif
break;
}
- if (!(info->port.flags & ASYNC_CLOSING) && do_clocal)
+ if (do_clocal)
/* && (do_clocal || DCD_IS_ASSERTED) */
break;
if (signal_pending(current)) {
@@ -3895,20 +3877,6 @@ rs_open(struct tty_struct *tty, struct file * filp)
info->port.low_latency = !!(info->port.flags & ASYNC_LOW_LATENCY);
/*
- * If the port is in the middle of closing, bail out now
- */
- if (info->port.flags & ASYNC_CLOSING) {
- wait_event_interruptible_tty(tty, info->port.close_wait,
- !(info->port.flags & ASYNC_CLOSING));
-#ifdef SERIAL_DO_RESTART
- return ((info->port.flags & ASYNC_HUP_NOTIFY) ?
- -EAGAIN : -ERESTARTSYS);
-#else
- return -EAGAIN;
-#endif
- }
-
- /*
* If DMA is enabled try to allocate the irq's.
*/
if (info->port.count == 1) {
OpenPOWER on IntegriCloud