summaryrefslogtreecommitdiffstats
path: root/drivers/thermal/cpu_cooling.c
diff options
context:
space:
mode:
authorThomas Gleixner <tglx@linutronix.de>2016-09-01 18:33:46 +0200
committerThomas Gleixner <tglx@linutronix.de>2016-09-01 18:33:46 +0200
commit0cb7bf61b1e9f05027de58c80f9b46a714d24e35 (patch)
tree41fb55cf62d07b425122f9a8b96412c0d8eb99c5 /drivers/thermal/cpu_cooling.c
parentaa877175e7a9982233ed8f10cb4bfddd78d82741 (diff)
parent3eab887a55424fc2c27553b7bfe32330df83f7b8 (diff)
downloadtalos-op-linux-0cb7bf61b1e9f05027de58c80f9b46a714d24e35.tar.gz
talos-op-linux-0cb7bf61b1e9f05027de58c80f9b46a714d24e35.zip
Merge branch 'linus' into smp/hotplug
Apply upstream changes to avoid conflicts with pending patches.
Diffstat (limited to 'drivers/thermal/cpu_cooling.c')
-rw-r--r--drivers/thermal/cpu_cooling.c21
1 files changed, 16 insertions, 5 deletions
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
index 3788ed74c9ab..a32b41783b77 100644
--- a/drivers/thermal/cpu_cooling.c
+++ b/drivers/thermal/cpu_cooling.c
@@ -740,12 +740,22 @@ static int cpufreq_power2state(struct thermal_cooling_device *cdev,
}
/* Bind cpufreq callbacks to thermal cooling device ops */
+
static struct thermal_cooling_device_ops cpufreq_cooling_ops = {
.get_max_state = cpufreq_get_max_state,
.get_cur_state = cpufreq_get_cur_state,
.set_cur_state = cpufreq_set_cur_state,
};
+static struct thermal_cooling_device_ops cpufreq_power_cooling_ops = {
+ .get_max_state = cpufreq_get_max_state,
+ .get_cur_state = cpufreq_get_cur_state,
+ .set_cur_state = cpufreq_set_cur_state,
+ .get_requested_power = cpufreq_get_requested_power,
+ .state2power = cpufreq_state2power,
+ .power2state = cpufreq_power2state,
+};
+
/* Notifier for cpufreq policy change */
static struct notifier_block thermal_cpufreq_notifier_block = {
.notifier_call = cpufreq_thermal_notifier,
@@ -795,6 +805,7 @@ __cpufreq_cooling_register(struct device_node *np,
struct cpumask temp_mask;
unsigned int freq, i, num_cpus;
int ret;
+ struct thermal_cooling_device_ops *cooling_ops;
cpumask_and(&temp_mask, clip_cpus, cpu_online_mask);
policy = cpufreq_cpu_get(cpumask_first(&temp_mask));
@@ -850,10 +861,6 @@ __cpufreq_cooling_register(struct device_node *np,
cpumask_copy(&cpufreq_dev->allowed_cpus, clip_cpus);
if (capacitance) {
- cpufreq_cooling_ops.get_requested_power =
- cpufreq_get_requested_power;
- cpufreq_cooling_ops.state2power = cpufreq_state2power;
- cpufreq_cooling_ops.power2state = cpufreq_power2state;
cpufreq_dev->plat_get_static_power = plat_static_func;
ret = build_dyn_power_table(cpufreq_dev, capacitance);
@@ -861,6 +868,10 @@ __cpufreq_cooling_register(struct device_node *np,
cool_dev = ERR_PTR(ret);
goto free_table;
}
+
+ cooling_ops = &cpufreq_power_cooling_ops;
+ } else {
+ cooling_ops = &cpufreq_cooling_ops;
}
ret = get_idr(&cpufreq_idr, &cpufreq_dev->id);
@@ -885,7 +896,7 @@ __cpufreq_cooling_register(struct device_node *np,
cpufreq_dev->id);
cool_dev = thermal_of_cooling_device_register(np, dev_name, cpufreq_dev,
- &cpufreq_cooling_ops);
+ cooling_ops);
if (IS_ERR(cool_dev))
goto remove_idr;
OpenPOWER on IntegriCloud