summaryrefslogtreecommitdiffstats
path: root/drivers/power/supply/ab8500_bmdata.c
diff options
context:
space:
mode:
authorSebastian Reichel <sre@kernel.org>2016-06-17 13:54:32 +0200
committerSebastian Reichel <sre@kernel.org>2016-08-11 01:11:03 +0200
commit8c0984e5a75337df513047ec92a6c09d78e3e5cd (patch)
treea2fc0a0dd7c7c40d9379bdd1c2b279c0959d0e1f /drivers/power/supply/ab8500_bmdata.c
parent29b4817d4018df78086157ea3a55c1d9424a7cfc (diff)
downloadtalos-op-linux-8c0984e5a75337df513047ec92a6c09d78e3e5cd.tar.gz
talos-op-linux-8c0984e5a75337df513047ec92a6c09d78e3e5cd.zip
power: move power supply drivers to power/supply
This moves all power supply drivers from drivers/power/ to drivers/power/supply/. The intention is a cleaner source tree, since drivers/power/ also contains frameworks unrelated to power supply, like adaptive voltage scaling. Signed-off-by: Sebastian Reichel <sre@kernel.org>
Diffstat (limited to 'drivers/power/supply/ab8500_bmdata.c')
-rw-r--r--drivers/power/supply/ab8500_bmdata.c605
1 files changed, 605 insertions, 0 deletions
diff --git a/drivers/power/supply/ab8500_bmdata.c b/drivers/power/supply/ab8500_bmdata.c
new file mode 100644
index 000000000000..d29864533093
--- /dev/null
+++ b/drivers/power/supply/ab8500_bmdata.c
@@ -0,0 +1,605 @@
+#include <linux/export.h>
+#include <linux/power_supply.h>
+#include <linux/of.h>
+#include <linux/mfd/abx500.h>
+#include <linux/mfd/abx500/ab8500.h>
+#include <linux/mfd/abx500/ab8500-bm.h>
+
+/*
+ * These are the defined batteries that uses a NTC and ID resistor placed
+ * inside of the battery pack.
+ * Note that the res_to_temp table must be strictly sorted by falling resistance
+ * values to work.
+ */
+const struct abx500_res_to_temp ab8500_temp_tbl_a_thermistor[] = {
+ {-5, 53407},
+ { 0, 48594},
+ { 5, 43804},
+ {10, 39188},
+ {15, 34870},
+ {20, 30933},
+ {25, 27422},
+ {30, 24347},
+ {35, 21694},
+ {40, 19431},
+ {45, 17517},
+ {50, 15908},
+ {55, 14561},
+ {60, 13437},
+ {65, 12500},
+};
+EXPORT_SYMBOL(ab8500_temp_tbl_a_thermistor);
+
+const int ab8500_temp_tbl_a_size = ARRAY_SIZE(ab8500_temp_tbl_a_thermistor);
+EXPORT_SYMBOL(ab8500_temp_tbl_a_size);
+
+const struct abx500_res_to_temp ab8500_temp_tbl_b_thermistor[] = {
+ {-5, 200000},
+ { 0, 159024},
+ { 5, 151921},
+ {10, 144300},
+ {15, 136424},
+ {20, 128565},
+ {25, 120978},
+ {30, 113875},
+ {35, 107397},
+ {40, 101629},
+ {45, 96592},
+ {50, 92253},
+ {55, 88569},
+ {60, 85461},
+ {65, 82869},
+};
+EXPORT_SYMBOL(ab8500_temp_tbl_b_thermistor);
+
+const int ab8500_temp_tbl_b_size = ARRAY_SIZE(ab8500_temp_tbl_b_thermistor);
+EXPORT_SYMBOL(ab8500_temp_tbl_b_size);
+
+static const struct abx500_v_to_cap cap_tbl_a_thermistor[] = {
+ {4171, 100},
+ {4114, 95},
+ {4009, 83},
+ {3947, 74},
+ {3907, 67},
+ {3863, 59},
+ {3830, 56},
+ {3813, 53},
+ {3791, 46},
+ {3771, 33},
+ {3754, 25},
+ {3735, 20},
+ {3717, 17},
+ {3681, 13},
+ {3664, 8},
+ {3651, 6},
+ {3635, 5},
+ {3560, 3},
+ {3408, 1},
+ {3247, 0},
+};
+
+static const struct abx500_v_to_cap cap_tbl_b_thermistor[] = {
+ {4161, 100},
+ {4124, 98},
+ {4044, 90},
+ {4003, 85},
+ {3966, 80},
+ {3933, 75},
+ {3888, 67},
+ {3849, 60},
+ {3813, 55},
+ {3787, 47},
+ {3772, 30},
+ {3751, 25},
+ {3718, 20},
+ {3681, 16},
+ {3660, 14},
+ {3589, 10},
+ {3546, 7},
+ {3495, 4},
+ {3404, 2},
+ {3250, 0},
+};
+
+static const struct abx500_v_to_cap cap_tbl[] = {
+ {4186, 100},
+ {4163, 99},
+ {4114, 95},
+ {4068, 90},
+ {3990, 80},
+ {3926, 70},
+ {3898, 65},
+ {3866, 60},
+ {3833, 55},
+ {3812, 50},
+ {3787, 40},
+ {3768, 30},
+ {3747, 25},
+ {3730, 20},
+ {3705, 15},
+ {3699, 14},
+ {3684, 12},
+ {3672, 9},
+ {3657, 7},
+ {3638, 6},
+ {3556, 4},
+ {3424, 2},
+ {3317, 1},
+ {3094, 0},
+};
+
+/*
+ * Note that the res_to_temp table must be strictly sorted by falling
+ * resistance values to work.
+ */
+static const struct abx500_res_to_temp temp_tbl[] = {
+ {-5, 214834},
+ { 0, 162943},
+ { 5, 124820},
+ {10, 96520},
+ {15, 75306},
+ {20, 59254},
+ {25, 47000},
+ {30, 37566},
+ {35, 30245},
+ {40, 24520},
+ {45, 20010},
+ {50, 16432},
+ {55, 13576},
+ {60, 11280},
+ {65, 9425},
+};
+
+/*
+ * Note that the batres_vs_temp table must be strictly sorted by falling
+ * temperature values to work.
+ */
+static const struct batres_vs_temp temp_to_batres_tbl_thermistor[] = {
+ { 40, 120},
+ { 30, 135},
+ { 20, 165},
+ { 10, 230},
+ { 00, 325},
+ {-10, 445},
+ {-20, 595},
+};
+
+/*
+ * Note that the batres_vs_temp table must be strictly sorted by falling
+ * temperature values to work.
+ */
+static const struct batres_vs_temp temp_to_batres_tbl_ext_thermistor[] = {
+ { 60, 300},
+ { 30, 300},
+ { 20, 300},
+ { 10, 300},
+ { 00, 300},
+ {-10, 300},
+ {-20, 300},
+};
+
+/* battery resistance table for LI ION 9100 battery */
+static const struct batres_vs_temp temp_to_batres_tbl_9100[] = {
+ { 60, 180},
+ { 30, 180},
+ { 20, 180},
+ { 10, 180},
+ { 00, 180},
+ {-10, 180},
+ {-20, 180},
+};
+
+static struct abx500_battery_type bat_type_thermistor[] = {
+ [BATTERY_UNKNOWN] = {
+ /* First element always represent the UNKNOWN battery */
+ .name = POWER_SUPPLY_TECHNOLOGY_UNKNOWN,
+ .resis_high = 0,
+ .resis_low = 0,
+ .battery_resistance = 300,
+ .charge_full_design = 612,
+ .nominal_voltage = 3700,
+ .termination_vol = 4050,
+ .termination_curr = 200,
+ .recharge_cap = 95,
+ .normal_cur_lvl = 400,
+ .normal_vol_lvl = 4100,
+ .maint_a_cur_lvl = 400,
+ .maint_a_vol_lvl = 4050,
+ .maint_a_chg_timer_h = 60,
+ .maint_b_cur_lvl = 400,
+ .maint_b_vol_lvl = 4000,
+ .maint_b_chg_timer_h = 200,
+ .low_high_cur_lvl = 300,
+ .low_high_vol_lvl = 4000,
+ .n_temp_tbl_elements = ARRAY_SIZE(temp_tbl),
+ .r_to_t_tbl = temp_tbl,
+ .n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl),
+ .v_to_cap_tbl = cap_tbl,
+ .n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor),
+ .batres_tbl = temp_to_batres_tbl_thermistor,
+ },
+ {
+ .name = POWER_SUPPLY_TECHNOLOGY_LIPO,
+ .resis_high = 53407,
+ .resis_low = 12500,
+ .battery_resistance = 300,
+ .charge_full_design = 900,
+ .nominal_voltage = 3600,
+ .termination_vol = 4150,
+ .termination_curr = 80,
+ .recharge_cap = 95,
+ .normal_cur_lvl = 700,
+ .normal_vol_lvl = 4200,
+ .maint_a_cur_lvl = 600,
+ .maint_a_vol_lvl = 4150,
+ .maint_a_chg_timer_h = 60,
+ .maint_b_cur_lvl = 600,
+ .maint_b_vol_lvl = 4100,
+ .maint_b_chg_timer_h = 200,
+ .low_high_cur_lvl = 300,
+ .low_high_vol_lvl = 4000,
+ .n_temp_tbl_elements = ARRAY_SIZE(ab8500_temp_tbl_a_thermistor),
+ .r_to_t_tbl = ab8500_temp_tbl_a_thermistor,
+ .n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl_a_thermistor),
+ .v_to_cap_tbl = cap_tbl_a_thermistor,
+ .n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor),
+ .batres_tbl = temp_to_batres_tbl_thermistor,
+
+ },
+ {
+ .name = POWER_SUPPLY_TECHNOLOGY_LIPO,
+ .resis_high = 200000,
+ .resis_low = 82869,
+ .battery_resistance = 300,
+ .charge_full_design = 900,
+ .nominal_voltage = 3600,
+ .termination_vol = 4150,
+ .termination_curr = 80,
+ .recharge_cap = 95,
+ .normal_cur_lvl = 700,
+ .normal_vol_lvl = 4200,
+ .maint_a_cur_lvl = 600,
+ .maint_a_vol_lvl = 4150,
+ .maint_a_chg_timer_h = 60,
+ .maint_b_cur_lvl = 600,
+ .maint_b_vol_lvl = 4100,
+ .maint_b_chg_timer_h = 200,
+ .low_high_cur_lvl = 300,
+ .low_high_vol_lvl = 4000,
+ .n_temp_tbl_elements = ARRAY_SIZE(ab8500_temp_tbl_b_thermistor),
+ .r_to_t_tbl = ab8500_temp_tbl_b_thermistor,
+ .n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl_b_thermistor),
+ .v_to_cap_tbl = cap_tbl_b_thermistor,
+ .n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor),
+ .batres_tbl = temp_to_batres_tbl_thermistor,
+ },
+};
+
+static struct abx500_battery_type bat_type_ext_thermistor[] = {
+ [BATTERY_UNKNOWN] = {
+ /* First element always represent the UNKNOWN battery */
+ .name = POWER_SUPPLY_TECHNOLOGY_UNKNOWN,
+ .resis_high = 0,
+ .resis_low = 0,
+ .battery_resistance = 300,
+ .charge_full_design = 612,
+ .nominal_voltage = 3700,
+ .termination_vol = 4050,
+ .termination_curr = 200,
+ .recharge_cap = 95,
+ .normal_cur_lvl = 400,
+ .normal_vol_lvl = 4100,
+ .maint_a_cur_lvl = 400,
+ .maint_a_vol_lvl = 4050,
+ .maint_a_chg_timer_h = 60,
+ .maint_b_cur_lvl = 400,
+ .maint_b_vol_lvl = 4000,
+ .maint_b_chg_timer_h = 200,
+ .low_high_cur_lvl = 300,
+ .low_high_vol_lvl = 4000,
+ .n_temp_tbl_elements = ARRAY_SIZE(temp_tbl),
+ .r_to_t_tbl = temp_tbl,
+ .n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl),
+ .v_to_cap_tbl = cap_tbl,
+ .n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor),
+ .batres_tbl = temp_to_batres_tbl_thermistor,
+ },
+/*
+ * These are the batteries that doesn't have an internal NTC resistor to measure
+ * its temperature. The temperature in this case is measure with a NTC placed
+ * near the battery but on the PCB.
+ */
+ {
+ .name = POWER_SUPPLY_TECHNOLOGY_LIPO,
+ .resis_high = 76000,
+ .resis_low = 53000,
+ .battery_resistance = 300,
+ .charge_full_design = 900,
+ .nominal_voltage = 3700,
+ .termination_vol = 4150,
+ .termination_curr = 100,
+ .recharge_cap = 95,
+ .normal_cur_lvl = 700,
+ .normal_vol_lvl = 4200,
+ .maint_a_cur_lvl = 600,
+ .maint_a_vol_lvl = 4150,
+ .maint_a_chg_timer_h = 60,
+ .maint_b_cur_lvl = 600,
+ .maint_b_vol_lvl = 4100,
+ .maint_b_chg_timer_h = 200,
+ .low_high_cur_lvl = 300,
+ .low_high_vol_lvl = 4000,
+ .n_temp_tbl_elements = ARRAY_SIZE(temp_tbl),
+ .r_to_t_tbl = temp_tbl,
+ .n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl),
+ .v_to_cap_tbl = cap_tbl,
+ .n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor),
+ .batres_tbl = temp_to_batres_tbl_thermistor,
+ },
+ {
+ .name = POWER_SUPPLY_TECHNOLOGY_LION,
+ .resis_high = 30000,
+ .resis_low = 10000,
+ .battery_resistance = 300,
+ .charge_full_design = 950,
+ .nominal_voltage = 3700,
+ .termination_vol = 4150,
+ .termination_curr = 100,
+ .recharge_cap = 95,
+ .normal_cur_lvl = 700,
+ .normal_vol_lvl = 4200,
+ .maint_a_cur_lvl = 600,
+ .maint_a_vol_lvl = 4150,
+ .maint_a_chg_timer_h = 60,
+ .maint_b_cur_lvl = 600,
+ .maint_b_vol_lvl = 4100,
+ .maint_b_chg_timer_h = 200,
+ .low_high_cur_lvl = 300,
+ .low_high_vol_lvl = 4000,
+ .n_temp_tbl_elements = ARRAY_SIZE(temp_tbl),
+ .r_to_t_tbl = temp_tbl,
+ .n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl),
+ .v_to_cap_tbl = cap_tbl,
+ .n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor),
+ .batres_tbl = temp_to_batres_tbl_thermistor,
+ },
+ {
+ .name = POWER_SUPPLY_TECHNOLOGY_LION,
+ .resis_high = 95000,
+ .resis_low = 76001,
+ .battery_resistance = 300,
+ .charge_full_design = 950,
+ .nominal_voltage = 3700,
+ .termination_vol = 4150,
+ .termination_curr = 100,
+ .recharge_cap = 95,
+ .normal_cur_lvl = 700,
+ .normal_vol_lvl = 4200,
+ .maint_a_cur_lvl = 600,
+ .maint_a_vol_lvl = 4150,
+ .maint_a_chg_timer_h = 60,
+ .maint_b_cur_lvl = 600,
+ .maint_b_vol_lvl = 4100,
+ .maint_b_chg_timer_h = 200,
+ .low_high_cur_lvl = 300,
+ .low_high_vol_lvl = 4000,
+ .n_temp_tbl_elements = ARRAY_SIZE(temp_tbl),
+ .r_to_t_tbl = temp_tbl,
+ .n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl),
+ .v_to_cap_tbl = cap_tbl,
+ .n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor),
+ .batres_tbl = temp_to_batres_tbl_thermistor,
+ },
+};
+
+static const struct abx500_bm_capacity_levels cap_levels = {
+ .critical = 2,
+ .low = 10,
+ .normal = 70,
+ .high = 95,
+ .full = 100,
+};
+
+static const struct abx500_fg_parameters fg = {
+ .recovery_sleep_timer = 10,
+ .recovery_total_time = 100,
+ .init_timer = 1,
+ .init_discard_time = 5,
+ .init_total_time = 40,
+ .high_curr_time = 60,
+ .accu_charging = 30,
+ .accu_high_curr = 30,
+ .high_curr_threshold = 50,
+ .lowbat_threshold = 3100,
+ .battok_falling_th_sel0 = 2860,
+ .battok_raising_th_sel1 = 2860,
+ .maint_thres = 95,
+ .user_cap_limit = 15,
+ .pcut_enable = 1,
+ .pcut_max_time = 127,
+ .pcut_flag_time = 112,
+ .pcut_max_restart = 15,
+ .pcut_debounce_time = 2,
+};
+
+static const struct abx500_maxim_parameters ab8500_maxi_params = {
+ .ena_maxi = true,
+ .chg_curr = 910,
+ .wait_cycles = 10,
+ .charger_curr_step = 100,
+};
+
+static const struct abx500_maxim_parameters abx540_maxi_params = {
+ .ena_maxi = true,
+ .chg_curr = 3000,
+ .wait_cycles = 10,
+ .charger_curr_step = 200,
+};
+
+static const struct abx500_bm_charger_parameters chg = {
+ .usb_volt_max = 5500,
+ .usb_curr_max = 1500,
+ .ac_volt_max = 7500,
+ .ac_curr_max = 1500,
+};
+
+/*
+ * This array maps the raw hex value to charger output current used by the
+ * AB8500 values
+ */
+static int ab8500_charge_output_curr_map[] = {
+ 100, 200, 300, 400, 500, 600, 700, 800,
+ 900, 1000, 1100, 1200, 1300, 1400, 1500, 1500,
+};
+
+static int ab8540_charge_output_curr_map[] = {
+ 0, 0, 0, 75, 100, 125, 150, 175,
+ 200, 225, 250, 275, 300, 325, 350, 375,
+ 400, 425, 450, 475, 500, 525, 550, 575,
+ 600, 625, 650, 675, 700, 725, 750, 775,
+ 800, 825, 850, 875, 900, 925, 950, 975,
+ 1000, 1025, 1050, 1075, 1100, 1125, 1150, 1175,
+ 1200, 1225, 1250, 1275, 1300, 1325, 1350, 1375,
+ 1400, 1425, 1450, 1500, 1600, 1700, 1900, 2000,
+};
+
+/*
+ * This array maps the raw hex value to charger input current used by the
+ * AB8500 values
+ */
+static int ab8500_charge_input_curr_map[] = {
+ 50, 98, 193, 290, 380, 450, 500, 600,
+ 700, 800, 900, 1000, 1100, 1300, 1400, 1500,
+};
+
+static int ab8540_charge_input_curr_map[] = {
+ 25, 50, 75, 100, 125, 150, 175, 200,
+ 225, 250, 275, 300, 325, 350, 375, 400,
+ 425, 450, 475, 500, 525, 550, 575, 600,
+ 625, 650, 675, 700, 725, 750, 775, 800,
+ 825, 850, 875, 900, 925, 950, 975, 1000,
+ 1025, 1050, 1075, 1100, 1125, 1150, 1175, 1200,
+ 1225, 1250, 1275, 1300, 1325, 1350, 1375, 1400,
+ 1425, 1450, 1475, 1500, 1500, 1500, 1500, 1500,
+};
+
+struct abx500_bm_data ab8500_bm_data = {
+ .temp_under = 3,
+ .temp_low = 8,
+ .temp_high = 43,
+ .temp_over = 48,
+ .main_safety_tmr_h = 4,
+ .temp_interval_chg = 20,
+ .temp_interval_nochg = 120,
+ .usb_safety_tmr_h = 4,
+ .bkup_bat_v = BUP_VCH_SEL_2P6V,
+ .bkup_bat_i = BUP_ICH_SEL_150UA,
+ .no_maintenance = false,
+ .capacity_scaling = false,
+ .adc_therm = ABx500_ADC_THERM_BATCTRL,
+ .chg_unknown_bat = false,
+ .enable_overshoot = false,
+ .fg_res = 100,
+ .cap_levels = &cap_levels,
+ .bat_type = bat_type_thermistor,
+ .n_btypes = ARRAY_SIZE(bat_type_thermistor),
+ .batt_id = 0,
+ .interval_charging = 5,
+ .interval_not_charging = 120,
+ .temp_hysteresis = 3,
+ .gnd_lift_resistance = 34,
+ .chg_output_curr = ab8500_charge_output_curr_map,
+ .n_chg_out_curr = ARRAY_SIZE(ab8500_charge_output_curr_map),
+ .maxi = &ab8500_maxi_params,
+ .chg_params = &chg,
+ .fg_params = &fg,
+ .chg_input_curr = ab8500_charge_input_curr_map,
+ .n_chg_in_curr = ARRAY_SIZE(ab8500_charge_input_curr_map),
+};
+
+struct abx500_bm_data ab8540_bm_data = {
+ .temp_under = 3,
+ .temp_low = 8,
+ .temp_high = 43,
+ .temp_over = 48,
+ .main_safety_tmr_h = 4,
+ .temp_interval_chg = 20,
+ .temp_interval_nochg = 120,
+ .usb_safety_tmr_h = 4,
+ .bkup_bat_v = BUP_VCH_SEL_2P6V,
+ .bkup_bat_i = BUP_ICH_SEL_150UA,
+ .no_maintenance = false,
+ .capacity_scaling = false,
+ .adc_therm = ABx500_ADC_THERM_BATCTRL,
+ .chg_unknown_bat = false,
+ .enable_overshoot = false,
+ .fg_res = 100,
+ .cap_levels = &cap_levels,
+ .bat_type = bat_type_thermistor,
+ .n_btypes = ARRAY_SIZE(bat_type_thermistor),
+ .batt_id = 0,
+ .interval_charging = 5,
+ .interval_not_charging = 120,
+ .temp_hysteresis = 3,
+ .gnd_lift_resistance = 0,
+ .maxi = &abx540_maxi_params,
+ .chg_params = &chg,
+ .fg_params = &fg,
+ .chg_output_curr = ab8540_charge_output_curr_map,
+ .n_chg_out_curr = ARRAY_SIZE(ab8540_charge_output_curr_map),
+ .chg_input_curr = ab8540_charge_input_curr_map,
+ .n_chg_in_curr = ARRAY_SIZE(ab8540_charge_input_curr_map),
+};
+
+int ab8500_bm_of_probe(struct device *dev,
+ struct device_node *np,
+ struct abx500_bm_data *bm)
+{
+ const struct batres_vs_temp *tmp_batres_tbl;
+ struct device_node *battery_node;
+ const char *btech;
+ int i;
+
+ /* get phandle to 'battery-info' node */
+ battery_node = of_parse_phandle(np, "battery", 0);
+ if (!battery_node) {
+ dev_err(dev, "battery node or reference missing\n");
+ return -EINVAL;
+ }
+
+ btech = of_get_property(battery_node, "stericsson,battery-type", NULL);
+ if (!btech) {
+ dev_warn(dev, "missing property battery-name/type\n");
+ return -EINVAL;
+ }
+
+ if (strncmp(btech, "LION", 4) == 0) {
+ bm->no_maintenance = true;
+ bm->chg_unknown_bat = true;
+ bm->bat_type[BATTERY_UNKNOWN].charge_full_design = 2600;
+ bm->bat_type[BATTERY_UNKNOWN].termination_vol = 4150;
+ bm->bat_type[BATTERY_UNKNOWN].recharge_cap = 95;
+ bm->bat_type[BATTERY_UNKNOWN].normal_cur_lvl = 520;
+ bm->bat_type[BATTERY_UNKNOWN].normal_vol_lvl = 4200;
+ }
+
+ if (of_property_read_bool(battery_node, "thermistor-on-batctrl")) {
+ if (strncmp(btech, "LION", 4) == 0)
+ tmp_batres_tbl = temp_to_batres_tbl_9100;
+ else
+ tmp_batres_tbl = temp_to_batres_tbl_thermistor;
+ } else {
+ bm->n_btypes = 4;
+ bm->bat_type = bat_type_ext_thermistor;
+ bm->adc_therm = ABx500_ADC_THERM_BATTEMP;
+ tmp_batres_tbl = temp_to_batres_tbl_ext_thermistor;
+ }
+
+ /* select the battery resolution table */
+ for (i = 0; i < bm->n_btypes; ++i)
+ bm->bat_type[i].batres_tbl = tmp_batres_tbl;
+
+ of_node_put(battery_node);
+
+ return 0;
+}
OpenPOWER on IntegriCloud