pm2301: Update watchdog for pm2xxx support
AB and PMxxx doesn't have same watchdog refresh period. Add watchdog
to refresh period parameters in x500 charger structure, this should
kick watchdog every 30sec. The AC charging should also kick both
pm2xxx and the AB charger watchdog.
Signed-off-by: Rajkumar Kasirajan <rajkumar.kasirajan@stericsson.com>
Signed-off-by: Loic Pallardy <loic.pallardy@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Michel JAOUEN <michel.jaouen@stericsson.com>
Reviewed-by: Marcus COOPER <marcus.xm.cooper@stericsson.com>
Reviewed-by: Jonas ABERG <jonas.aberg@stericsson.com>
Tested-by: Michel JAOUEN <michel.jaouen@stericsson.com>
Tested-by: Jonas ABERG <jonas.aberg@stericsson.com>
Diffstat (limited to 'drivers/power/pm2301_charger.c')
-rw-r--r-- | drivers/power/pm2301_charger.c | 2 |
1 files changed, 2 insertions, 0 deletions
diff --git a/drivers/power/pm2301_charger.c b/drivers/power/pm2301_charger.c index 085e468d8a2b..8c1dd5628d16 100644 --- a/drivers/power/pm2301_charger.c +++ b/drivers/power/pm2301_charger.c @@ -875,7 +875,9 @@ static int __devinit pm2xxx_wall_charger_probe(struct i2c_client *i2c_client, ARRAY_SIZE(pm2xxx_charger_voltage_map) - 1]; pm2->ac_chg.max_out_curr = pm2xxx_charger_current_map[ ARRAY_SIZE(pm2xxx_charger_current_map) - 1]; + pm2->ac_chg.wdt_refresh = WD_KICK_INTERVAL; pm2->ac_chg.enabled = true; + pm2->ac_chg.external = true; /* Create a work queue for the charger */ pm2->charger_wq = |