diff options
author | Linas Vepstas <linas@austin.ibm.com> | 2007-11-25 23:51:37 -0800 |
---|---|---|
committer | Greg Kroah-Hartman <gregkh@suse.de> | 2008-02-01 15:04:22 -0800 |
commit | 1b7c9fcaa147662628078c83ecaf1ef2c5c9c9d0 (patch) | |
tree | b563e65c2caf1d095c7352d1db1b4e47a014496d /drivers/pci/hotplug/rpaphp_pci.c | |
parent | 677cc6443b28508bb1a34d4d0d6a9b9a20179369 (diff) | |
download | talos-op-linux-1b7c9fcaa147662628078c83ecaf1ef2c5c9c9d0.tar.gz talos-op-linux-1b7c9fcaa147662628078c83ecaf1ef2c5c9c9d0.zip |
pci hotplug: fix rpaphp directory naming
Fix presentation of the slot number in the /sys/bus/pci/slots
directory to match that used in the majority of other drivers.
> Greg said:
> How is anyone supposed to write sane managability tools in the
> presence
> of such anarchy?
>
> > ~ # cat /sys/bus/pci/slots/0000:00:02.2/phy_location
> > U787A.001.DNZ00Z5-P1-C2
>
> Right. This should look like:
>
> # cat /sys/bus/pci/slots/U787A.001.DNZ00Z5-P1-C2/address
> 0000:00:02
This patch implements exactly what you describe. Boot tested.
I assume you really mean it -- if so, then please review and
ack the patch !?
I have absolutely no clue if this breaks any existing IBM tools.
I'm pretty sure it doesn't ... but attention Mike Strosaker! does it?
Signed-off-by: Linas Vepstas <linas@austin.ibm.com>
Cc: Kristen Carlson Accardi <kristen.c.accardi@intel.com>
Cc: <strosake@us.ibm.com>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
Diffstat (limited to 'drivers/pci/hotplug/rpaphp_pci.c')
-rw-r--r-- | drivers/pci/hotplug/rpaphp_pci.c | 14 |
1 files changed, 0 insertions, 14 deletions
diff --git a/drivers/pci/hotplug/rpaphp_pci.c b/drivers/pci/hotplug/rpaphp_pci.c index 0de84533cd80..6571e9b4c2ec 100644 --- a/drivers/pci/hotplug/rpaphp_pci.c +++ b/drivers/pci/hotplug/rpaphp_pci.c @@ -64,19 +64,6 @@ int rpaphp_get_sensor_state(struct slot *slot, int *state) return rc; } -static void set_slot_name(struct slot *slot) -{ - struct pci_bus *bus = slot->bus; - struct pci_dev *bridge; - - bridge = bus->self; - if (bridge) - strcpy(slot->name, pci_name(bridge)); - else - sprintf(slot->name, "%04x:%02x:00.0", pci_domain_nr(bus), - bus->number); -} - /** * rpaphp_enable_slot - record slot state, config pci device * @slot: target &slot @@ -115,7 +102,6 @@ int rpaphp_enable_slot(struct slot *slot) info->adapter_status = EMPTY; slot->bus = bus; slot->pci_devs = &bus->devices; - set_slot_name(slot); /* if there's an adapter in the slot, go add the pci devices */ if (state == PRESENT) { |