summaryrefslogtreecommitdiffstats
path: root/drivers/gpu
diff options
context:
space:
mode:
authorLucas Stach <l.stach@pengutronix.de>2016-08-20 00:01:24 +0200
committerLucas Stach <l.stach@pengutronix.de>2016-09-15 15:29:41 +0200
commit2e145a22486610100cb2c6d789f56bd0c6f27718 (patch)
tree218b6719f6094822e630ba54748dd901ed66cd32 /drivers/gpu
parentde08e8ef71cd7fbc4a89107b295571c4d50f0d66 (diff)
downloadtalos-op-linux-2e145a22486610100cb2c6d789f56bd0c6f27718.tar.gz
talos-op-linux-2e145a22486610100cb2c6d789f56bd0c6f27718.zip
drm/etnaviv: add flushing logic for MMUv2
Flushing works differently on MMUv2, in that it's only necessary to set a single bit in the control register to flush all translation units. A semaphore stall then makes sure that the flush has propagated properly. Signed-off-by: Lucas Stach <l.stach@pengutronix.de>
Diffstat (limited to 'drivers/gpu')
-rw-r--r--drivers/gpu/drm/etnaviv/etnaviv_buffer.c31
1 files changed, 23 insertions, 8 deletions
diff --git a/drivers/gpu/drm/etnaviv/etnaviv_buffer.c b/drivers/gpu/drm/etnaviv/etnaviv_buffer.c
index 47b93427fecb..cb86c7e5495c 100644
--- a/drivers/gpu/drm/etnaviv/etnaviv_buffer.c
+++ b/drivers/gpu/drm/etnaviv/etnaviv_buffer.c
@@ -276,8 +276,12 @@ void etnaviv_buffer_queue(struct etnaviv_gpu *gpu, unsigned int event,
extra_dwords = 1;
/* flush command */
- if (gpu->mmu->need_flush)
- extra_dwords += 1;
+ if (gpu->mmu->need_flush) {
+ if (gpu->mmu->version == ETNAVIV_IOMMU_V1)
+ extra_dwords += 1;
+ else
+ extra_dwords += 3;
+ }
/* pipe switch commands */
if (gpu->switch_context)
@@ -287,12 +291,23 @@ void etnaviv_buffer_queue(struct etnaviv_gpu *gpu, unsigned int event,
if (gpu->mmu->need_flush) {
/* Add the MMU flush */
- CMD_LOAD_STATE(buffer, VIVS_GL_FLUSH_MMU,
- VIVS_GL_FLUSH_MMU_FLUSH_FEMMU |
- VIVS_GL_FLUSH_MMU_FLUSH_UNK1 |
- VIVS_GL_FLUSH_MMU_FLUSH_UNK2 |
- VIVS_GL_FLUSH_MMU_FLUSH_PEMMU |
- VIVS_GL_FLUSH_MMU_FLUSH_UNK4);
+ if (gpu->mmu->version == ETNAVIV_IOMMU_V1) {
+ CMD_LOAD_STATE(buffer, VIVS_GL_FLUSH_MMU,
+ VIVS_GL_FLUSH_MMU_FLUSH_FEMMU |
+ VIVS_GL_FLUSH_MMU_FLUSH_UNK1 |
+ VIVS_GL_FLUSH_MMU_FLUSH_UNK2 |
+ VIVS_GL_FLUSH_MMU_FLUSH_PEMMU |
+ VIVS_GL_FLUSH_MMU_FLUSH_UNK4);
+ } else {
+ CMD_LOAD_STATE(buffer, VIVS_MMUv2_CONFIGURATION,
+ VIVS_MMUv2_CONFIGURATION_MODE_MASK |
+ VIVS_MMUv2_CONFIGURATION_ADDRESS_MASK |
+ VIVS_MMUv2_CONFIGURATION_FLUSH_FLUSH);
+ CMD_SEM(buffer, SYNC_RECIPIENT_FE,
+ SYNC_RECIPIENT_PE);
+ CMD_STALL(buffer, SYNC_RECIPIENT_FE,
+ SYNC_RECIPIENT_PE);
+ }
gpu->mmu->need_flush = false;
}
OpenPOWER on IntegriCloud