summaryrefslogtreecommitdiffstats
path: root/drivers/gpu/drm/drm_modes.c
diff options
context:
space:
mode:
authorJason Gunthorpe <jgg@mellanox.com>2019-08-21 14:12:29 -0300
committerJason Gunthorpe <jgg@mellanox.com>2019-08-21 20:58:18 -0300
commitdaa138a58c802e7b4c2fb73f9b85bb082616ef43 (patch)
treebe913e8e3745bb367d2ba371598f447649102cfc /drivers/gpu/drm/drm_modes.c
parent6869b7b206595ae0e326f59719090351eb8f4f5d (diff)
parentfba0e448a2c5b297a4ddc1ec4e48f4aa6600a1c9 (diff)
downloadtalos-op-linux-daa138a58c802e7b4c2fb73f9b85bb082616ef43.tar.gz
talos-op-linux-daa138a58c802e7b4c2fb73f9b85bb082616ef43.zip
Merge branch 'odp_fixes' into hmm.git
From rdma.git Jason Gunthorpe says: ==================== This is a collection of general cleanups for ODP to clarify some of the flows around umem creation and use of the interval tree. ==================== The branch is based on v5.3-rc5 due to dependencies, and is being taken into hmm.git due to dependencies in the next patches. * odp_fixes: RDMA/mlx5: Use odp instead of mr->umem in pagefault_mr RDMA/mlx5: Use ib_umem_start instead of umem.address RDMA/core: Make invalidate_range a device operation RDMA/odp: Use kvcalloc for the dma_list and page_list RDMA/odp: Check for overflow when computing the umem_odp end RDMA/odp: Provide ib_umem_odp_release() to undo the allocs RDMA/odp: Split creating a umem_odp from ib_umem_get RDMA/odp: Make the three ways to create a umem_odp clear RMDA/odp: Consolidate umem_odp initialization RDMA/odp: Make it clearer when a umem is an implicit ODP umem RDMA/odp: Iterate over the whole rbtree directly RDMA/odp: Use the common interval tree library instead of generic RDMA/mlx5: Fix MR npages calculation for IB_ACCESS_HUGETLB Signed-off-by: Jason Gunthorpe <jgg@mellanox.com>
Diffstat (limited to 'drivers/gpu/drm/drm_modes.c')
-rw-r--r--drivers/gpu/drm/drm_modes.c6
1 files changed, 4 insertions, 2 deletions
diff --git a/drivers/gpu/drm/drm_modes.c b/drivers/gpu/drm/drm_modes.c
index 74a5739df506..b0369e690f36 100644
--- a/drivers/gpu/drm/drm_modes.c
+++ b/drivers/gpu/drm/drm_modes.c
@@ -1686,7 +1686,7 @@ static int drm_mode_parse_cmdline_options(char *str, size_t len,
*
* Additionals options can be provided following the mode, using a comma to
* separate each option. Valid options can be found in
- * Documentation/fb/modedb.txt.
+ * Documentation/fb/modedb.rst.
*
* The intermediate drm_cmdline_mode structure is required to store additional
* options from the command line modline like the force-enable/disable flag.
@@ -1770,7 +1770,9 @@ bool drm_mode_parse_command_line_for_connector(const char *mode_option,
}
if (named_mode) {
- strncpy(mode->name, name, mode_end);
+ if (mode_end + 1 > DRM_DISPLAY_MODE_LEN)
+ return false;
+ strscpy(mode->name, name, mode_end + 1);
} else {
ret = drm_mode_parse_cmdline_res_mode(name, mode_end,
parse_extras,
OpenPOWER on IntegriCloud