summaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon/sht15.rst
diff options
context:
space:
mode:
authorMauro Carvalho Chehab <mchehab+samsung@kernel.org>2019-04-17 06:46:29 -0300
committerGuenter Roeck <linux@roeck-us.net>2019-04-17 10:37:23 -0700
commit7ebd8b66dd9e5a0b65e5ee5e2b8e7ca382ec97b7 (patch)
tree9db30159bd32bec125c7d49e80a79bb7c4da0c8e /Documentation/hwmon/sht15.rst
parentb04f2f7d387b3160883c2a1f5e2285483a791e82 (diff)
downloadtalos-op-linux-7ebd8b66dd9e5a0b65e5ee5e2b8e7ca382ec97b7.tar.gz
talos-op-linux-7ebd8b66dd9e5a0b65e5ee5e2b8e7ca382ec97b7.zip
docs: hwmon: Add an index file and rename docs to *.rst
Now that all files were converted to ReST format, rename them and add an index. Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'Documentation/hwmon/sht15.rst')
-rw-r--r--Documentation/hwmon/sht15.rst83
1 files changed, 83 insertions, 0 deletions
diff --git a/Documentation/hwmon/sht15.rst b/Documentation/hwmon/sht15.rst
new file mode 100644
index 000000000000..485abe037f6c
--- /dev/null
+++ b/Documentation/hwmon/sht15.rst
@@ -0,0 +1,83 @@
+Kernel driver sht15
+===================
+
+Authors:
+
+ * Wouter Horre
+ * Jonathan Cameron
+ * Vivien Didelot <vivien.didelot@savoirfairelinux.com>
+ * Jerome Oufella <jerome.oufella@savoirfairelinux.com>
+
+Supported chips:
+
+ * Sensirion SHT10
+
+ Prefix: 'sht10'
+
+ * Sensirion SHT11
+
+ Prefix: 'sht11'
+
+ * Sensirion SHT15
+
+ Prefix: 'sht15'
+
+ * Sensirion SHT71
+
+ Prefix: 'sht71'
+
+ * Sensirion SHT75
+
+ Prefix: 'sht75'
+
+Datasheet: Publicly available at the Sensirion website
+
+ http://www.sensirion.ch/en/pdf/product_information/Datasheet-humidity-sensor-SHT1x.pdf
+
+Description
+-----------
+
+The SHT10, SHT11, SHT15, SHT71, and SHT75 are humidity and temperature
+sensors.
+
+The devices communicate using two GPIO lines.
+
+Supported resolutions for the measurements are 14 bits for temperature and 12
+bits for humidity, or 12 bits for temperature and 8 bits for humidity.
+
+The humidity calibration coefficients are programmed into an OTP memory on the
+chip. These coefficients are used to internally calibrate the signals from the
+sensors. Disabling the reload of those coefficients allows saving 10ms for each
+measurement and decrease power consumption, while losing on precision.
+
+Some options may be set via sysfs attributes.
+
+Notes:
+ * The regulator supply name is set to "vcc".
+ * If a CRC validation fails, a soft reset command is sent, which resets
+ status register to its hardware default value, but the driver will try to
+ restore the previous device configuration.
+
+Platform data
+-------------
+
+* checksum:
+ set it to true to enable CRC validation of the readings (default to false).
+* no_otp_reload:
+ flag to indicate not to reload from OTP (default to false).
+* low_resolution:
+ flag to indicate the temp/humidity resolution to use (default to false).
+
+Sysfs interface
+---------------
+
+================== ==========================================================
+temp1_input temperature input
+humidity1_input humidity input
+heater_enable write 1 in this attribute to enable the on-chip heater,
+ 0 to disable it. Be careful not to enable the heater
+ for too long.
+temp1_fault if 1, this means that the voltage is low (below 2.47V) and
+ measurement may be invalid.
+humidity1_fault same as temp1_fault.
+================== ==========================================================