ARM: shmobile: lager: phy fixup needs CONFIG_PHYLIB
Do not build the phy fixup unless CONFIG_PHYLIB is enabled.
Other than not being useful it is also not possible to link
the code under this condition as phy_register_fixup_for_id(),
mdiobus_read() and mdiobus_write() are absent.
arch/arm/mach-shmobile/built-in.o: In function `lager_ksz8041_fixup':
board-lager.c:(.text+0xb8): undefined reference to `mdiobus_read'
board-lager.c:(.text+0xd4): undefined reference to `mdiobus_write'
arch/arm/mach-shmobile/built-in.o: In function `lager_init':
board-lager.c:(.init.text+0xafc): undefined reference to `phy_register_fixup_for_id'
This problem was introduced by 48c8b96f21817aad
("ARM: shmobile: Lager: add Micrel KSZ8041 PHY fixup")
Cc: Sergei Shtylyov <sergei.shtylyov@cogentembedded.com>
Signed-off-by: Simon Horman <horms+renesas@verge.net.au>
-rw-r--r-- | arch/arm/mach-shmobile/board-lager.c | 4 |
1 files changed, 3 insertions, 1 deletions
diff --git a/arch/arm/mach-shmobile/board-lager.c b/arch/arm/mach-shmobile/board-lager.c index a8d3ce646fb9..e0406fd37390 100644 --- a/arch/arm/mach-shmobile/board-lager.c +++ b/arch/arm/mach-shmobile/board-lager.c @@ -245,7 +245,9 @@ static void __init lager_init(void) { lager_add_standard_devices(); - phy_register_fixup_for_id("r8a7790-ether-ff:01", lager_ksz8041_fixup); + if (IS_ENABLED(CONFIG_PHYLIB)) + phy_register_fixup_for_id("r8a7790-ether-ff:01", + lager_ksz8041_fixup); } static const char * const lager_boards_compat_dt[] __initconst = { |