diff options
author | Chris Cain <cjcain@us.ibm.com> | 2017-02-09 16:33:10 -0600 |
---|---|---|
committer | Christopher J. Cain <cjcain@us.ibm.com> | 2017-02-14 12:39:24 -0500 |
commit | 5f3814b53d0262bf5be162b89f7aaca3b014dcec (patch) | |
tree | b8c11e57b74f43428995a84673a62fcbcda64694 /src/occ_405/amec/amec_sensors_power.c | |
parent | 1747f6fbb5ad8e61e31c4c320bbff01e5636da62 (diff) | |
download | talos-occ-5f3814b53d0262bf5be162b89f7aaca3b014dcec.tar.gz talos-occ-5f3814b53d0262bf5be162b89f7aaca3b014dcec.zip |
AVS Bus update to use 32bit register accesses instead of 64
Change-Id: Ib31cb6ba5cc23f2599226628d36c7006dc911249
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/36250
Reviewed-by: William A. Bryan <wilbryan@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Martha Broyles <mbroyles@us.ibm.com>
Reviewed-by: Christopher J. Cain <cjcain@us.ibm.com>
Diffstat (limited to 'src/occ_405/amec/amec_sensors_power.c')
-rwxr-xr-x | src/occ_405/amec/amec_sensors_power.c | 11 |
1 files changed, 6 insertions, 5 deletions
diff --git a/src/occ_405/amec/amec_sensors_power.c b/src/occ_405/amec/amec_sensors_power.c index 622a9f4..1950510 100755 --- a/src/occ_405/amec/amec_sensors_power.c +++ b/src/occ_405/amec/amec_sensors_power.c @@ -469,7 +469,7 @@ void update_avsbus_power_sensors(const avsbus_type_e i_type) static bool L_throttle_vdn = FALSE; bool * L_throttle = &L_throttle_vdd; // TODO: RTC 130216 : read loadline and distloss from Pstate Super Structure - uint32_t l_loadline = 0x61AB; // OCCPstateParmBlock.vdd_sysparm.loadline_uohm + uint32_t l_loadline = 0x0000; // OCCPstateParmBlock.vdd_sysparm.loadline_uohm uint32_t l_distloss = 0x0000; // OCCPstateParmBlock.vdd_sysparm.distloss_uohm uint32_t l_currentSensor = CURVDD; uint32_t l_voltageSensor = VOLTVDD; @@ -478,7 +478,7 @@ void update_avsbus_power_sensors(const avsbus_type_e i_type) if (AVSBUS_VDN == i_type) { L_throttle = &L_throttle_vdn; - l_loadline = 0x6BA8; // OCCPstateParmBlock.vdn_sysparm.loadline_uohm + l_loadline = 0x0000; // OCCPstateParmBlock.vdn_sysparm.loadline_uohm l_distloss = 0x0000; // OCCPstateParmBlock.vdn_sysparm.distloss_uohm l_currentSensor = CURVDN; l_voltageSensor = VOLTVDN; @@ -503,7 +503,8 @@ void update_avsbus_power_sensors(const avsbus_type_e i_type) #ifdef AVSDEBUG // TODO: RTC 130216 : REMOVE AFTER VERIFYING loadline/distlost from Pstate Super Structure static uint32_t L_traceCount = 0; - if (L_traceCount < 4) + uint32_t DEBUG_TRACE_MAX = 8; + if (L_traceCount < DEBUG_TRACE_MAX) { TRAC_INFO("update_avsbus_power_sensors: #%d Vd%c=%dx100uV, I=%dx10mA", L_traceCount, (i_type==AVSBUS_VDD)?'d':'n', l_voltage_100uv, l_current_10ma); @@ -555,7 +556,7 @@ void update_avsbus_power_sensors(const avsbus_type_e i_type) #ifdef AVSDEBUG // TODO: RTC 130216 : REMOVE AFTER VERIFYING loadline/distlost from Pstate Super Structure - if (L_traceCount < 4) + if (L_traceCount < DEBUG_TRACE_MAX) { const sensor_t *power = getSensorByGsid(l_powerSensor); TRAC_INFO("update_avsbus_power_sensors: #%d Vd%cs=%dx100uV, P=%dW", L_traceCount, (i_type==AVSBUS_VDD)?'d':'n', @@ -566,7 +567,7 @@ void update_avsbus_power_sensors(const avsbus_type_e i_type) #ifdef AVSDEBUG // TODO: RTC 130216 : REMOVE AFTER VERIFYING loadline/distlost from Pstate Super Structure - if (L_traceCount < 4) + if (L_traceCount < DEBUG_TRACE_MAX) { ++L_traceCount; } |