summaryrefslogtreecommitdiffstats
path: root/drivers/pci/pci.c
diff options
context:
space:
mode:
authorPeter Tyser <ptyser@xes-inc.com>2010-10-29 17:59:29 -0500
committerWolfgang Denk <wd@denx.de>2010-11-14 23:46:48 +0100
commit009884ae35362d6a4edf04c4af8aad78d415a261 (patch)
tree66c6fbbf69d2300aa50e4003e4857734dc0a337f /drivers/pci/pci.c
parenta38d216eeb80663b89c0a3e6c43f28aeaf09b2e7 (diff)
downloadtalos-obmc-uboot-009884ae35362d6a4edf04c4af8aad78d415a261.tar.gz
talos-obmc-uboot-009884ae35362d6a4edf04c4af8aad78d415a261.zip
pci: Use intelligent indentation for CONFIG_PCI_SCAN_SHOW
When CONFIG_PCI_SCAN_SHOW is defined U-Boot prints out PCI devices as they are found during bootup, eg: PCIE1: connected as Root Complex 01:00.0 - 10b5:8518 - Bridge device 02:01.0 - 10b5:8518 - Bridge device 03:00.0 - 10b5:8112 - Bridge device 04:01.0 - 8086:1010 - Network controller 04:01.1 - 8086:1010 - Network controller 02:02.0 - 10b5:8518 - Bridge device 02:03.0 - 10b5:8518 - Bridge device 06:00.0 - 10b5:8518 - Bridge device 07:00.0 - 10b5:8518 - Bridge device 08:00.0 - 1957:0040 - Processor 07:01.0 - 10b5:8518 - Bridge device 09:00.0 - 10b5:8112 - Bridge device 07:02.0 - 10b5:8518 - Bridge device PCIE1: Bus 00 - 0b PCIE2: connected as Root Complex 0d:00.0 - 1957:0040 - Processor PCIE2: Bus 0c - 0d This information is useful, but its difficult to determine the PCI bus topology. To things clearer, we can use indention to make it more obvious how the PCI bus is organized. For the example above, the updated output with this change is: PCIE1: connected as Root Complex 01:00.0 - 10b5:8518 - Bridge device 02:01.0 - 10b5:8518 - Bridge device 03:00.0 - 10b5:8112 - Bridge device 04:01.0 - 8086:1010 - Network controller 04:01.1 - 8086:1010 - Network controller 02:02.0 - 10b5:8518 - Bridge device 02:03.0 - 10b5:8518 - Bridge device 06:00.0 - 10b5:8518 - Bridge device 07:00.0 - 10b5:8518 - Bridge device 08:00.0 - 1957:0040 - Processor 07:01.0 - 10b5:8518 - Bridge device 09:00.0 - 10b5:8112 - Bridge device 07:02.0 - 10b5:8518 - Bridge device PCIE1: Bus 00 - 0b PCIE2: connected as Root Complex 0d:00.0 - 1957:0040 - Processor PCIE2: Bus 0c - 0d In the examples above, an MPC8640 is connected to a PEX8518 PCIe switch (01:00 and 02:0x), which is connected to another PEX8518 PCIe switch (06:00 and 07:0x), which then connects to a MPC8572 processor (08:00). Also, the MPC8640's PEX8518 PCIe switch is connected to a PCI ethernet card (04:01) via a PEX8112 PCIe-to-PCI bridge (03:00). Signed-off-by: Peter Tyser <ptyser@xes-inc.com>
Diffstat (limited to 'drivers/pci/pci.c')
-rw-r--r--drivers/pci/pci.c16
1 files changed, 14 insertions, 2 deletions
diff --git a/drivers/pci/pci.c b/drivers/pci/pci.c
index 78f7339e35..702ac67826 100644
--- a/drivers/pci/pci.c
+++ b/drivers/pci/pci.c
@@ -616,6 +616,9 @@ int pci_hose_scan_bus(struct pci_controller *hose, int bus)
unsigned char header_type;
struct pci_config_table *cfg;
pci_dev_t dev;
+#ifdef CONFIG_PCI_SCAN_SHOW
+ static int indent = 0;
+#endif
sub_bus = bus;
@@ -646,9 +649,14 @@ int pci_hose_scan_bus(struct pci_controller *hose, int bus)
pci_hose_read_config_word(hose, dev, PCI_CLASS_DEVICE, &class);
#ifdef CONFIG_PCI_SCAN_SHOW
+ indent++;
+
+ /* Print leading space, including bus indentation */
+ printf("%*c", indent + 1, ' ');
+
if (pci_print_dev(hose, dev)) {
- printf(" %02x:%02x.%x - %04x:%04x - %s\n",
- PCI_BUS(dev), PCI_DEV(dev), PCI_FUNC(dev),
+ printf("%02x:%02x.%-*x - %04x:%04x - %s\n",
+ PCI_BUS(dev), PCI_DEV(dev), 6 - indent, PCI_FUNC(dev),
vendor, device, pci_class_str(class >> 8));
}
#endif
@@ -666,6 +674,10 @@ int pci_hose_scan_bus(struct pci_controller *hose, int bus)
#endif
}
+#ifdef CONFIG_PCI_SCAN_SHOW
+ indent--;
+#endif
+
if (hose->fixup_irq)
hose->fixup_irq(hose, dev);
}
OpenPOWER on IntegriCloud