summaryrefslogtreecommitdiffstats
path: root/fs/gfs2/ops_inode.c
diff options
context:
space:
mode:
authorSteven Whitehouse <swhiteho@redhat.com>2008-01-10 15:18:55 +0000
committerSteven Whitehouse <swhiteho@redhat.com>2008-01-25 08:18:25 +0000
commit6dbd822487d0a9f14432cb4680415b80656b63a2 (patch)
treef0391d598c27cd7c39c67cfa13799a784f4c389a /fs/gfs2/ops_inode.c
parentac39aadd0440ae696e6dacaa8006ce1737b17008 (diff)
downloadtalos-obmc-linux-6dbd822487d0a9f14432cb4680415b80656b63a2.tar.gz
talos-obmc-linux-6dbd822487d0a9f14432cb4680415b80656b63a2.zip
[GFS2] Reduce inode size by moving i_alloc out of line
It is possible to reduce the size of GFS2 inodes by taking the i_alloc structure out of the gfs2_inode. This patch allocates the i_alloc structure whenever its needed, and frees it afterward. This decreases the amount of low memory we use at the expense of requiring a memory allocation for each page or partial page that we write. A quick test with postmark shows that the overhead is not measurable and I also note that OCFS2 use the same approach. In the future I'd like to solve the problem by shrinking down the size of the members of the i_alloc structure, but for now, this reduces the immediate problem of using too much low-memory on x86 and doesn't add too much overhead. Signed-off-by: Steven Whitehouse <swhiteho@redhat.com>
Diffstat (limited to 'fs/gfs2/ops_inode.c')
-rw-r--r--fs/gfs2/ops_inode.c8
1 files changed, 4 insertions, 4 deletions
diff --git a/fs/gfs2/ops_inode.c b/fs/gfs2/ops_inode.c
index 8386ab323e33..9f71372c1757 100644
--- a/fs/gfs2/ops_inode.c
+++ b/fs/gfs2/ops_inode.c
@@ -61,7 +61,7 @@ static int gfs2_create(struct inode *dir, struct dentry *dentry,
inode = gfs2_createi(ghs, &dentry->d_name, S_IFREG | mode, 0);
if (!IS_ERR(inode)) {
gfs2_trans_end(sdp);
- if (dip->i_alloc.al_rgd)
+ if (dip->i_alloc->al_rgd)
gfs2_inplace_release(dip);
gfs2_quota_unlock(dip);
gfs2_alloc_put(dip);
@@ -376,7 +376,7 @@ static int gfs2_symlink(struct inode *dir, struct dentry *dentry,
}
gfs2_trans_end(sdp);
- if (dip->i_alloc.al_rgd)
+ if (dip->i_alloc->al_rgd)
gfs2_inplace_release(dip);
gfs2_quota_unlock(dip);
gfs2_alloc_put(dip);
@@ -452,7 +452,7 @@ static int gfs2_mkdir(struct inode *dir, struct dentry *dentry, int mode)
gfs2_assert_withdraw(sdp, !error); /* dip already pinned */
gfs2_trans_end(sdp);
- if (dip->i_alloc.al_rgd)
+ if (dip->i_alloc->al_rgd)
gfs2_inplace_release(dip);
gfs2_quota_unlock(dip);
gfs2_alloc_put(dip);
@@ -558,7 +558,7 @@ static int gfs2_mknod(struct inode *dir, struct dentry *dentry, int mode,
}
gfs2_trans_end(sdp);
- if (dip->i_alloc.al_rgd)
+ if (dip->i_alloc->al_rgd)
gfs2_inplace_release(dip);
gfs2_quota_unlock(dip);
gfs2_alloc_put(dip);
OpenPOWER on IntegriCloud