diff options
author | Steve French <smfrench@gmail.com> | 2017-07-08 18:48:15 -0500 |
---|---|---|
committer | Steve French <smfrench@gmail.com> | 2017-07-08 18:57:07 -0500 |
commit | 2a38e12053b760a8f5e85030eb89512660077c15 (patch) | |
tree | 63c2fb7884899653fb85a5249708bccc58e1e9ef /fs/cifs/cifsfs.c | |
parent | 511c54a2f69195b28afb9dd119f03787b1625bb4 (diff) | |
download | talos-obmc-linux-2a38e12053b760a8f5e85030eb89512660077c15.tar.gz talos-obmc-linux-2a38e12053b760a8f5e85030eb89512660077c15.zip |
[SMB3] Remove ifdef since SMB3 (and later) now STRONGLY preferred
Remove the CONFIG_CIFS_SMB2 ifdef and Kconfig option since they
must always be on now.
For various security reasons, SMB3 and later are STRONGLY preferred
over CIFS and older dialects, and SMB3 (and later) will now be
the default dialects so we do not want to allow them to be
ifdeffed out.
In the longer term, we may be able to make older CIFS support
disableable in Kconfig with a new set of #ifdef, but we always
want SMB3 and later support enabled.
Signed-off-by: Steven French <smfrench@gmail.com>
Reviewed-by: Pavel Shilovsky <pshilov@microsoft.com>
Diffstat (limited to 'fs/cifs/cifsfs.c')
-rw-r--r-- | fs/cifs/cifsfs.c | 13 |
1 files changed, 3 insertions, 10 deletions
diff --git a/fs/cifs/cifsfs.c b/fs/cifs/cifsfs.c index 9a1667e0e8d6..556f480c6936 100644 --- a/fs/cifs/cifsfs.c +++ b/fs/cifs/cifsfs.c @@ -51,9 +51,7 @@ #include <linux/key-type.h> #include "cifs_spnego.h" #include "fscache.h" -#ifdef CONFIG_CIFS_SMB2 #include "smb2pdu.h" -#endif int cifsFYI = 0; bool traceSMB; @@ -277,9 +275,8 @@ cifs_alloc_inode(struct super_block *sb) cifs_inode->uniqueid = 0; cifs_inode->createtime = 0; cifs_inode->epoch = 0; -#ifdef CONFIG_CIFS_SMB2 generate_random_uuid(cifs_inode->lease_key); -#endif + /* * Can not set i_flags here - they get immediately overwritten to zero * by the VFS. @@ -1213,14 +1210,12 @@ cifs_destroy_inodecache(void) static int cifs_init_request_bufs(void) { - size_t max_hdr_size = MAX_CIFS_HDR_SIZE; -#ifdef CONFIG_CIFS_SMB2 /* * SMB2 maximum header size is bigger than CIFS one - no problems to * allocate some more bytes for CIFS. */ - max_hdr_size = MAX_SMB2_HDR_SIZE; -#endif + size_t max_hdr_size = MAX_SMB2_HDR_SIZE; + if (CIFSMaxBufSize < 8192) { /* Buffer size can not be smaller than 2 * PATH_MAX since maximum Unicode path name has to fit in any SMB/CIFS path based frames */ @@ -1476,12 +1471,10 @@ MODULE_SOFTDEP("pre: hmac"); MODULE_SOFTDEP("pre: md4"); MODULE_SOFTDEP("pre: md5"); MODULE_SOFTDEP("pre: nls"); -#ifdef CONFIG_CIFS_SMB2 MODULE_SOFTDEP("pre: aes"); MODULE_SOFTDEP("pre: cmac"); MODULE_SOFTDEP("pre: sha256"); MODULE_SOFTDEP("pre: aead2"); MODULE_SOFTDEP("pre: ccm"); -#endif /* CONFIG_CIFS_SMB2 */ module_init(init_cifs) module_exit(exit_cifs) |