diff options
author | Bart Van Assche <bart.vanassche@wdc.com> | 2018-06-25 08:05:16 -0700 |
---|---|---|
committer | Martin K. Petersen <martin.petersen@oracle.com> | 2018-06-26 12:30:11 -0400 |
commit | c2cdef95160440ed6291bc343139d958ba3261e4 (patch) | |
tree | 9c2e4057c514ba2eabd657beeba2b24cd1bf5407 /drivers/scsi/qedi | |
parent | 6bec4c3842cd7338973839683bbf96273c3b85f7 (diff) | |
download | talos-obmc-linux-c2cdef95160440ed6291bc343139d958ba3261e4.tar.gz talos-obmc-linux-c2cdef95160440ed6291bc343139d958ba3261e4.zip |
scsi: qedi: Fix misleading indentation
This patch avoids that smatch reports the following warnings:
drivers/scsi/qedi/qedi_fw_api.c:129: init_sqe() warn: inconsistent indenting
drivers/scsi/qedi/qedi_fw_api.c:137: init_sqe() warn: inconsistent indenting
Signed-off-by: Bart Van Assche <bart.vanassche@wdc.com>
Cc: QLogic-Storage-Upstream@cavium.com
Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Diffstat (limited to 'drivers/scsi/qedi')
-rw-r--r-- | drivers/scsi/qedi/qedi_fw_api.c | 30 |
1 files changed, 16 insertions, 14 deletions
diff --git a/drivers/scsi/qedi/qedi_fw_api.c b/drivers/scsi/qedi/qedi_fw_api.c index a269da1a6c75..387dc87e4d22 100644 --- a/drivers/scsi/qedi/qedi_fw_api.c +++ b/drivers/scsi/qedi/qedi_fw_api.c @@ -126,22 +126,24 @@ static void init_sqe(struct iscsi_task_params *task_params, sgl_task_params, dif_task_params); - if (scsi_is_slow_sgl(sgl_task_params->num_sges, - sgl_task_params->small_mid_sge)) - num_sges = ISCSI_WQE_NUM_SGES_SLOWIO; - else - num_sges = min(sgl_task_params->num_sges, - (u16)SCSI_NUM_SGES_SLOW_SGL_THR); - } + if (scsi_is_slow_sgl(sgl_task_params->num_sges, + sgl_task_params->small_mid_sge)) + num_sges = ISCSI_WQE_NUM_SGES_SLOWIO; + else + num_sges = min(sgl_task_params->num_sges, + (u16)SCSI_NUM_SGES_SLOW_SGL_THR); + } - SET_FIELD(task_params->sqe->flags, ISCSI_WQE_NUM_SGES, num_sges); - SET_FIELD(task_params->sqe->contlen_cdbsize, ISCSI_WQE_CONT_LEN, - buf_size); + SET_FIELD(task_params->sqe->flags, ISCSI_WQE_NUM_SGES, + num_sges); + SET_FIELD(task_params->sqe->contlen_cdbsize, ISCSI_WQE_CONT_LEN, + buf_size); - if (GET_FIELD(pdu_header->hdr_second_dword, - ISCSI_CMD_HDR_TOTAL_AHS_LEN)) - SET_FIELD(task_params->sqe->contlen_cdbsize, ISCSI_WQE_CDB_SIZE, - cmd_params->extended_cdb_sge.sge_len); + if (GET_FIELD(pdu_header->hdr_second_dword, + ISCSI_CMD_HDR_TOTAL_AHS_LEN)) + SET_FIELD(task_params->sqe->contlen_cdbsize, + ISCSI_WQE_CDB_SIZE, + cmd_params->extended_cdb_sge.sge_len); } break; case ISCSI_TASK_TYPE_INITIATOR_READ: |