summaryrefslogtreecommitdiffstats
path: root/drivers/mtd
diff options
context:
space:
mode:
authorMatthieu CASTET <matthieu.castet@parrot.com>2012-11-06 11:51:44 +0100
committerArtem Bityutskiy <artem.bityutskiy@linux.intel.com>2012-12-03 16:36:52 +0200
commit64b37b2a63eb2f80b65c7185f0013f8ffc637ae3 (patch)
treeccc8cd81dbcbef0fb8d69856a00dfb795d78b80a /drivers/mtd
parent2fd71a294a0aac407ec69e04916dc28eb39c8ac0 (diff)
downloadtalos-obmc-linux-64b37b2a63eb2f80b65c7185f0013f8ffc637ae3.tar.gz
talos-obmc-linux-64b37b2a63eb2f80b65c7185f0013f8ffc637ae3.zip
mtd: nand: add NAND_BUSWIDTH_AUTO to autodetect bus width
The driver call nand_scan_ident in 8 bit mode, then readid or onfi detection are done (and detect bus width). The driver should update its bus width before calling nand_scan_tail. This work because readid and onfi are read work 8 byte mode. Note that nand_scan_ident send command (NAND_CMD_RESET, NAND_CMD_READID, NAND_CMD_PARAM), address and read data The ONFI specificication is not very clear for x16 device if high byte of address should be driven to 0, but according to [1] it should be ok to not drive it during autodetection. [1] 3.3.2. Target Initialization [...] The Read ID and Read Parameter Page commands only use the lower 8-bits of the data bus. The host shall not issue commands that use a word data width on x16 devices until the host determines the device supports a 16-bit data bus width in the parameter page. Signed-off-by: Matthieu CASTET <matthieu.castet@parrot.com> Signed-off-by: Artem Bityutskiy <artem.bityutskiy@linux.intel.com>
Diffstat (limited to 'drivers/mtd')
-rw-r--r--drivers/mtd/nand/nand_base.c14
1 files changed, 9 insertions, 5 deletions
diff --git a/drivers/mtd/nand/nand_base.c b/drivers/mtd/nand/nand_base.c
index 6f58e1633e2f..5851c51ac2df 100644
--- a/drivers/mtd/nand/nand_base.c
+++ b/drivers/mtd/nand/nand_base.c
@@ -3250,11 +3250,15 @@ ident_done:
break;
}
- /*
- * Check, if buswidth is correct. Hardware drivers should set
- * chip correct!
- */
- if (busw != (chip->options & NAND_BUSWIDTH_16)) {
+ if (chip->options & NAND_BUSWIDTH_AUTO) {
+ WARN_ON(chip->options & NAND_BUSWIDTH_16);
+ chip->options |= busw;
+ nand_set_defaults(chip, busw);
+ } else if (busw != (chip->options & NAND_BUSWIDTH_16)) {
+ /*
+ * Check, if buswidth is correct. Hardware drivers should set
+ * chip correct!
+ */
pr_info("NAND device: Manufacturer ID:"
" 0x%02x, Chip ID: 0x%02x (%s %s)\n", *maf_id,
*dev_id, nand_manuf_ids[maf_idx].name, mtd->name);
OpenPOWER on IntegriCloud