dm: raid fix device status indicator when array initializing
When devices in a RAID array are not in-sync, they are supposed to be reported as such in the status output as an 'a' character, which means "alive, but not in-sync". But when the entire array is rebuilt 'A' is being used, which is incorrect. This patch corrects this to 'a'. Signed-off-by: Jonathan Brassow <jbrassow@redhat.com> Signed-off-by: Alasdair G Kergon <agk@redhat.com>
Diffstat (limited to 'drivers/md')
-rw-r--r--drivers/md/dm-raid.c48
1 files changed, 37 insertions, 11 deletions
diff --git a/drivers/md/dm-raid.c b/drivers/md/dm-raid.c
index 86df8b2cf927..7503a20d04a7 100644
--- a/drivers/md/dm-raid.c
+++ b/drivers/md/dm-raid.c
@@ -1017,30 +1017,56 @@ static int raid_status(struct dm_target *ti, status_type_t type,
struct raid_set *rs = ti->private;
unsigned raid_param_cnt = 1; /* at least 1 for chunksize */
unsigned sz = 0;
- int i;
+ int i, array_in_sync = 0;
sector_t sync;
switch (type) {
case STATUSTYPE_INFO:
DMEMIT("%s %d ", rs->raid_type->name, rs->md.raid_disks);
- for (i = 0; i < rs->md.raid_disks; i++) {
- if (test_bit(Faulty, &rs->dev[i].rdev.flags))
- DMEMIT("D");
- else if (test_bit(In_sync, &rs->dev[i].rdev.flags))
- DMEMIT("A");
- else
- DMEMIT("a");
- }
-
if (test_bit(MD_RECOVERY_RUNNING, &rs->md.recovery))
sync = rs->md.curr_resync_completed;
else
sync = rs->md.recovery_cp;
- if (sync > rs->md.resync_max_sectors)
+ if (sync >= rs->md.resync_max_sectors) {
+ array_in_sync = 1;
sync = rs->md.resync_max_sectors;
+ } else {
+ /*
+ * The array may be doing an initial sync, or it may
+ * be rebuilding individual components. If all the
+ * devices are In_sync, then it is the array that is
+ * being initialized.
+ */
+ for (i = 0; i < rs->md.raid_disks; i++)
+ if (!test_bit(In_sync, &rs->dev[i].rdev.flags))
+ array_in_sync = 1;
+ }
+ /*
+ * Status characters:
+ * 'D' = Dead/Failed device
+ * 'a' = Alive but not in-sync
+ * 'A' = Alive and in-sync
+ */
+ for (i = 0; i < rs->md.raid_disks; i++) {
+ if (test_bit(Faulty, &rs->dev[i].rdev.flags))
+ DMEMIT("D");
+ else if (!array_in_sync ||
+ !test_bit(In_sync, &rs->dev[i].rdev.flags))
+ DMEMIT("a");
+ else
+ DMEMIT("A");
+ }
+ /*
+ * In-sync ratio:
+ * The in-sync ratio shows the progress of:
+ * - Initializing the array
+ * - Rebuilding a subset of devices of the array
+ * The user can distinguish between the two by referring
+ * to the status characters.
+ */
DMEMIT(" %llu/%llu",
(unsigned long long) sync,
(unsigned long long) rs->md.resync_max_sectors);