libata: allow LLDs w/o any reset method
Some old SFF controllers don't have any way to reset the channel. Currently, this isn't supported and libata EH causes an oops. Allow LLDs w/o any reset method and just assume ATA class in such cases. Signed-off-by: Tejun Heo <htejun@gmail.com> Signed-off-by: Ingo Molnar <mingo@elte.hu> Signed-off-by: Jeff Garzik <jeff@garzik.org>
Diffstat (limited to 'drivers/ata/libata-eh.c')
-rw-r--r--drivers/ata/libata-eh.c10
1 files changed, 10 insertions, 0 deletions
diff --git a/drivers/ata/libata-eh.c b/drivers/ata/libata-eh.c
index 698ce2cea52c..681252fd8143 100644
--- a/drivers/ata/libata-eh.c
+++ b/drivers/ata/libata-eh.c
@@ -2150,6 +2150,15 @@ int ata_eh_reset(struct ata_link *link, int classify,
ap->ops->set_piomode(ap, dev);
}
+ if (!softreset && !hardreset) {
+ if (verbose)
+ ata_link_printk(link, KERN_INFO, "no reset method "
+ "available, skipping reset\n");
+ if (!(lflags & ATA_LFLAG_ASSUME_CLASS))
+ lflags |= ATA_LFLAG_ASSUME_ATA;
+ goto done;
+ }
+
/* Determine which reset to use and record in ehc->i.action.
* prereset() may examine and modify it.
*/
@@ -2254,6 +2263,7 @@ int ata_eh_reset(struct ata_link *link, int classify,