authorBenjamin Herrenschmidt <benh@kernel.crashing.org>2012-02-05 13:50:04 +0000
committerBenjamin Herrenschmidt <benh@kernel.crashing.org>2012-02-14 15:01:38 +1100
commit454c0bfd0c6469276dec766e5b41efcf0ccf2619 (patch)
tree99b362fb2add3a0e5c9da2b1ed3e2624214bf8ef /arch
parent3ec1e88b33a3bdd852ce8e014052acec7a9da8b5 (diff)
downloadtalos-obmc-linux-454c0bfd0c6469276dec766e5b41efcf0ccf2619.tar.gz
talos-obmc-linux-454c0bfd0c6469276dec766e5b41efcf0ccf2619.zip
powerpc/wsp: Permanently enable PCI class code workaround
It appears that on the Chroma card, the class code of the root complex is still wrong even on DD2 or later chips. This could be a firmware issue, but that breaks resource allocation so let's unconditionally fix it up. Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org>
Diffstat (limited to 'arch')
-rw-r--r--arch/powerpc/platforms/wsp/wsp_pci.c8
1 files changed, 4 insertions, 4 deletions
diff --git a/arch/powerpc/platforms/wsp/wsp_pci.c b/arch/powerpc/platforms/wsp/wsp_pci.c
index e0262cd0e2d3..d24b3acf858e 100644
--- a/arch/powerpc/platforms/wsp/wsp_pci.c
+++ b/arch/powerpc/platforms/wsp/wsp_pci.c
@@ -468,15 +468,15 @@ static void __init wsp_pcie_configure_hw(struct pci_controller *hose)
#define DUMP_REG(x) \
pr_debug("%-30s : 0x%016llx\n", #x, in_be64(hose->cfg_data + x))
-#ifdef CONFIG_WSP_DD1_WORKAROUND_BAD_PCIE_CLASS
- /* WSP DD1 has a bogus class code by default in the PCI-E
- * root complex's built-in P2P bridge */
+ /*
+ * Some WSP variants has a bogus class code by default in the PCI-E
+ * root complex's built-in P2P bridge
+ */
val = in_be64(hose->cfg_data + PCIE_REG_SYS_CFG1);
pr_debug("PCI-E SYS_CFG1 : 0x%llx\n", val);
out_be64(hose->cfg_data + PCIE_REG_SYS_CFG1,
(val & ~PCIE_REG_SYS_CFG1_CLASS_CODE) | (PCI_CLASS_BRIDGE_PCI << 8));
pr_debug("PCI-E SYS_CFG1 : 0x%llx\n", in_be64(hose->cfg_data + PCIE_REG_SYS_CFG1));
-#endif /* CONFIG_WSP_DD1_WORKAROUND_BAD_PCIE_CLASS */