summaryrefslogtreecommitdiffstats
path: root/arch/parisc/Kconfig
diff options
context:
space:
mode:
authorHelge Deller <deller@gmx.de>2018-06-15 22:38:22 +0200
committerHelge Deller <deller@gmx.de>2018-06-28 17:34:43 +0200
commit435d34c7a48de5e89047ef9c7dce6528831b258b (patch)
treea3d4c6b1ff87023646d35182c428de71a97f2052 /arch/parisc/Kconfig
parent5e791d2e4785f9ec7da4a02b9e8d00dace9e6917 (diff)
downloadtalos-obmc-linux-435d34c7a48de5e89047ef9c7dce6528831b258b.tar.gz
talos-obmc-linux-435d34c7a48de5e89047ef9c7dce6528831b258b.zip
parisc: Default to 4 SMP CPUs
I haven't seen any real SMP machine yet with > 4 CPUs (we don't suport SuperDomes yet), so reducing the default maximum number of CPUs may speed up various bitop functions which depend on number of CPUs in the system. bload-o-meter on a typical 64-bit kernel shows: Data: add/remove: 0/0 grow/shrink: 0/10 up/down: 0/-3724 (-3724) Total: Before=1910404, After=1906680, chg -0.19% Code: add/remove: 0/2 grow/shrink: 42/38 up/down: 2320/-3500 (-1180) Total: Before=11053099, After=11051919, chg -0.01% Signed-off-by: Helge Deller <deller@gmx.de>
Diffstat (limited to 'arch/parisc/Kconfig')
-rw-r--r--arch/parisc/Kconfig2
1 files changed, 1 insertions, 1 deletions
diff --git a/arch/parisc/Kconfig b/arch/parisc/Kconfig
index a9a507a19540..17526bebcbd2 100644
--- a/arch/parisc/Kconfig
+++ b/arch/parisc/Kconfig
@@ -347,7 +347,7 @@ config NR_CPUS