diff options
author | Bryan Wu <bryan.wu@canonical.com> | 2012-03-14 02:26:56 +0800 |
---|---|---|
committer | Bryan Wu <bryan.wu@canonical.com> | 2012-08-01 11:22:14 +0800 |
commit | fa8bbb13ab49e77c00fa09e5504ec25b7176fb4b (patch) | |
tree | 33bea9e45b5a7ba6c68a861f7ea94446d9d0f497 /arch/arm/Kconfig | |
parent | 18775a7bea8fbbebe8818db7a64aaeb40b40a0c5 (diff) | |
download | talos-obmc-linux-fa8bbb13ab49e77c00fa09e5504ec25b7176fb4b.tar.gz talos-obmc-linux-fa8bbb13ab49e77c00fa09e5504ec25b7176fb4b.zip |
ARM: use new LEDS CPU trigger stub to replace old one
Cc: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Bryan Wu <bryan.wu@canonical.com>
Diffstat (limited to 'arch/arm/Kconfig')
-rw-r--r-- | arch/arm/Kconfig | 53 |
1 files changed, 0 insertions, 53 deletions
diff --git a/arch/arm/Kconfig b/arch/arm/Kconfig index a91009c61870..dc57d3792359 100644 --- a/arch/arm/Kconfig +++ b/arch/arm/Kconfig @@ -1739,59 +1739,6 @@ config FORCE_MAX_ZONEORDER This config option is actually maximum order plus one. For example, a value of 11 means that the largest free memory block is 2^10 pages. -config LEDS - bool "Timer and CPU usage LEDs" - depends on ARCH_CDB89712 || ARCH_EBSA110 || \ - ARCH_EBSA285 || ARCH_INTEGRATOR || \ - ARCH_LUBBOCK || MACH_MAINSTONE || ARCH_NETWINDER || \ - ARCH_OMAP || ARCH_P720T || ARCH_PXA_IDP || \ - ARCH_SA1100 || ARCH_SHARK || ARCH_VERSATILE || \ - ARCH_AT91 || ARCH_DAVINCI || \ - ARCH_KS8695 || MACH_RD88F5182 || ARCH_REALVIEW - help - If you say Y here, the LEDs on your machine will be used - to provide useful information about your current system status. - - If you are compiling a kernel for a NetWinder or EBSA-285, you will - be able to select which LEDs are active using the options below. If - you are compiling a kernel for the EBSA-110 or the LART however, the - red LED will simply flash regularly to indicate that the system is - still functional. It is safe to say Y here if you have a CATS - system, but the driver will do nothing. - -config LEDS_TIMER - bool "Timer LED" if (!ARCH_CDB89712 && !ARCH_OMAP) || \ - OMAP_OSK_MISTRAL || MACH_OMAP_H2 \ - || MACH_OMAP_PERSEUS2 - depends on LEDS - depends on !GENERIC_CLOCKEVENTS - default y if ARCH_EBSA110 - help - If you say Y here, one of the system LEDs (the green one on the - NetWinder, the amber one on the EBSA285, or the red one on the LART) - will flash regularly to indicate that the system is still - operational. This is mainly useful to kernel hackers who are - debugging unstable kernels. - - The LART uses the same LED for both Timer LED and CPU usage LED - functions. You may choose to use both, but the Timer LED function - will overrule the CPU usage LED. - -config LEDS_CPU - bool "CPU usage LED" if (!ARCH_CDB89712 && !ARCH_EBSA110 && \ - !ARCH_OMAP) \ - || OMAP_OSK_MISTRAL || MACH_OMAP_H2 \ - || MACH_OMAP_PERSEUS2 - depends on LEDS - help - If you say Y here, the red LED will be used to give a good real - time indication of CPU usage, by lighting whenever the idle task - is not currently executing. - - The LART uses the same LED for both Timer LED and CPU usage LED - functions. You may choose to use both, but the Timer LED function - will overrule the CPU usage LED. - config ALIGNMENT_TRAP bool depends on CPU_CP15_MMU |