Merge branch 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux
Pull thermal managament updates from Zhang Rui:
- Enhance thermal "userspace" governor to export the reason when a
thermal event is triggered and delivered to user space. From Srinivas
Pandruvada
- Introduce a single TSENS thermal driver for the different versions of
the TSENS IP that exist, on different qcom msm/apq SoCs'. Support for
msm8916, msm8960, msm8974 and msm8996 families is also added. From
Rajendra Nayak
- Introduce hardware-tracked trip points support to the device tree
thermal sensor framework. The framework supports an arbitrary number
of trip points. Whenever the current temperature is changed, the trip
points immediately below and above the current temperature are found,
driver callback is invoked to program the hardware to get notified
when either of the two trip points are triggered. Hardware-tracked
trip points support for rockchip thermal driver is also added at the
same time. From Sascha Hauer, Caesar Wang
- Introduce a new thermal driver, which enables TMU (Thermal Monitor
Unit) on QorIQ platform. From Jia Hongtao
- Introduce a new thermal driver for Maxim MAX77620. From Laxman
Dewangan
- Introduce a new thermal driver for Intel platforms using WhiskeyCove
PMIC. From Bin Gao
- Add mt2701 chip support to MTK thermal driver. From Dawei Chien
- Enhance Tegra thermal driver to enable soctherm node and set
"critical", "hot" trips, for Tegra124, Tegra132, Tegra210. From Wei
Ni
- Add resume support for tango thermal driver. From Marc Gonzalez
- several small fixes and improvements for rockchip, qcom, imx, rcar,
mtk thermal drivers and thermal core code. From Caesar Wang, Keerthy,
Rocky Hao, Wei Yongjun, Peter Robinson, Bui Duc Phuc, Axel Lin, Hugh
Kang
* 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux: (48 commits)
thermal: int3403: Process trip change notification
thermal: int340x: New Interface to read trip and notify
thermal: user_space gov: Add additional information in uevent
thermal: Enhance thermal_zone_device_update for events
arm64: tegra: set hot trips for Tegra210
arm64: tegra: set critical trips for Tegra210
arm64: tegra: add soctherm node for Tegra210
arm64: tegra: set hot trips for Tegra132
arm64: tegra: set critical trips for Tegra132
arm64: tegra: use tegra132-soctherm for Tegra132
arm: tegra: set hot trips for Tegra124
arm: tegra: set critical trips for Tegra124
thermal: tegra: add hw-throttle for Tegra132
thermal: tegra: add hw-throttle function
of: Add bindings of hw throttle for Tegra soctherm
thermal: mtk_thermal: Check return value of devm_thermal_zone_of_sensor_register
thermal: Add Mediatek thermal driver for mt2701.
dt-bindings: thermal: Add binding document for Mediatek thermal controller
thermal: max77620: Add thermal driver for reporting junction temp
thermal: max77620: Add DT binding doc for thermal driver
...
Diffstat (limited to 'Documentation')
5 files changed, 232 insertions, 3 deletions
diff --git a/Documentation/devicetree/bindings/thermal/max77620_thermal.txt b/Documentation/devicetree/bindings/thermal/max77620_thermal.txt new file mode 100644 index 000000000000..323a3b3822aa --- /dev/null +++ b/Documentation/devicetree/bindings/thermal/max77620_thermal.txt @@ -0,0 +1,70 @@ +Thermal driver for MAX77620 Power management IC from Maxim Semiconductor. + +Maxim Semiconductor MAX77620 supports alarm interrupts when its +die temperature crosses 120C and 140C. These threshold temperatures +are not configurable. Device does not provide the real temperature +of die other than just indicating whether temperature is above or +below threshold level. + +Required properties: +------------------- +#thermal-sensor-cells: Please refer <devicetree/bindings/thermal/thermal.txt> + for more details. + The value must be 0. + +For more details, please refer generic thermal DT binding document +<devicetree/bindings/thermal/thermal.txt>. + +Please refer <devicetree/bindings/mfd/max77620.txt> for mfd DT binding +document for the MAX77620. + +Example: +-------- +#include <dt-bindings/mfd/max77620.h> +#include <dt-bindings/thermal/thermal.h> +... + +i2c@7000d000 { + spmic: max77620@3c { + compatible = "maxim,max77620"; + ::::: + #thermal-sensor-cells = <0>; + ::: + }; +}; + +cool_dev: cool-dev { + compatible = "cooling-dev"; + #cooling-cells = <2>; +}; + +thermal-zones { + PMIC-Die { + polling-delay = <0>; + polling-delay-passive = <0>; + thermal-sensors = <&spmic>; + + trips { + pmic_die_warn_temp_thresh: hot-die { + temperature = <120000>; + type = "hot"; + hysteresis = <0>; + }; + + pmic_die_cirt_temp_thresh: cirtical-die { + temperature = <140000>; + type = "critical"; + hysteresis = <0>; + }; + }; + + cooling-maps { + map0 { + trip = <&pmic_die_warn_temp_thresh>; + cooling-device = <&cool_dev THERMAL_NO_LIMIT + THERMAL_NO_LIMIT>; + contribution = <100>; + }; + }; + }; +}; diff --git a/Documentation/devicetree/bindings/thermal/mediatek-thermal.txt b/Documentation/devicetree/bindings/thermal/mediatek-thermal.txt index 81f9a512bc2a..e2f494d74d8a 100644 --- a/Documentation/devicetree/bindings/thermal/mediatek-thermal.txt +++ b/Documentation/devicetree/bindings/thermal/mediatek-thermal.txt @@ -8,7 +8,9 @@ apmixedsys register space via AHB bus accesses, so a phandle to the APMIXEDSYS is also needed. Required properties: -- compatible: "mediatek,mt8173-thermal" +- compatible: + - "mediatek,mt8173-thermal" : For MT8173 family of SoCs + - "mediatek,mt2701-thermal" : For MT2701 family of SoCs - reg: Address range of the thermal controller - interrupts: IRQ for the thermal controller - clocks, clock-names: Clocks needed for the thermal controller. required diff --git a/Documentation/devicetree/bindings/thermal/nvidia,tegra124-soctherm.txt b/Documentation/devicetree/bindings/thermal/nvidia,tegra124-soctherm.txt index edebfa0a985e..b6c0ae53d4dc 100644 --- a/Documentation/devicetree/bindings/thermal/nvidia,tegra124-soctherm.txt +++ b/Documentation/devicetree/bindings/thermal/nvidia,tegra124-soctherm.txt @@ -10,8 +10,14 @@ Required properties : - compatible : For Tegra124, must contain "nvidia,tegra124-soctherm". For Tegra132, must contain "nvidia,tegra132-soctherm". For Tegra210, must contain "nvidia,tegra210-soctherm". -- reg : Should contain 1 entry: +- reg : Should contain at least 2 entries for each entry in reg-names: - SOCTHERM register set + - Tegra CAR register set: Required for Tegra124 and Tegra210. + - CCROC register set: Required for Tegra132. +- reg-names : Should contain at least 2 entries: + - soctherm-reg + - car-reg + - ccroc-reg - interrupts : Defines the interrupt used by SOCTHERM - clocks : Must contain an entry for each entry in clock-names. See ../clocks/clock-bindings.txt for details. @@ -25,17 +31,45 @@ Required properties : - #thermal-sensor-cells : Should be 1. See ./thermal.txt for a description of this property. See <dt-bindings/thermal/tegra124-soctherm.h> for a list of valid values when referring to thermal sensors. +- throttle-cfgs: A sub-node which is a container of configuration for each + hardware throttle events. These events can be set as cooling devices. + * throttle events: Sub-nodes must be named as "light" or "heavy". + Properties: + - nvidia,priority: Each throttles has its own throttle settings, so the + SW need to set priorities for various throttle, the HW arbiter can select + the final throttle settings. + Bigger value indicates higher priority, In general, higher priority + translates to lower target frequency. SW needs to ensure that critical + thermal alarms are given higher priority, and ensure that there is + no race if priority of two vectors is set to the same value. + The range of this value is 1~100. + - nvidia,cpu-throt-percent: This property is for Tegra124 and Tegra210. + It is the throttling depth of pulse skippers, it's the percentage + throttling. + - nvidia,cpu-throt-level: This property is only for Tegra132, it is the + level of pulse skippers, which used to throttle clock frequencies. It + indicates cpu clock throttling depth, and the depth can be programmed. + Must set as following values: + TEGRA_SOCTHERM_THROT_LEVEL_LOW, TEGRA_SOCTHERM_THROT_LEVEL_MED + TEGRA_SOCTHERM_THROT_LEVEL_HIGH, TEGRA_SOCTHERM_THROT_LEVEL_NONE + - #cooling-cells: Should be 1. This cooling device only support on/off state. + See ./thermal.txt for a description of this property. Note: - the "critical" type trip points will be set to SOC_THERM hardware as the shut down temperature. Once the temperature of this thermal zone is higher than it, the system will be shutdown or reset by hardware. +- the "hot" type trip points will be set to SOC_THERM hardware as the throttle +temperature. Once the the temperature of this thermal zone is higher +than it, it will trigger the HW throttle event. Example : soctherm@700e2000 { compatible = "nvidia,tegra124-soctherm"; - reg = <0x0 0x700e2000 0x0 0x1000>; + reg = <0x0 0x700e2000 0x0 0x600 /* SOC_THERM reg_base */ + 0x0 0x60006000 0x0 0x400 /* CAR reg_base */ + reg-names = "soctherm-reg", "car-reg"; interrupts = <GIC_SPI 48 IRQ_TYPE_LEVEL_HIGH>; clocks = <&tegra_car TEGRA124_CLK_TSENSOR>, <&tegra_car TEGRA124_CLK_SOC_THERM>; @@ -44,6 +78,76 @@ Example : reset-names = "soctherm"; #thermal-sensor-cells = <1>; + + throttle-cfgs { + /* + * When the "heavy" cooling device triggered, + * the HW will skip cpu clock's pulse in 85% depth + */ + throttle_heavy: heavy { + nvidia,priority = <100>; + nvidia,cpu-throt-percent = <85>; + + #cooling-cells = <1>; + }; + + /* + * When the "light" cooling device triggered, + * the HW will skip cpu clock's pulse in 50% depth + */ + throttle_light: light { + nvidia,priority = <80>; + nvidia,cpu-throt-percent = <50>; + + #cooling-cells = <1>; + }; + + /* + * If these two devices are triggered in same time, the HW throttle + * arbiter will select the highest priority as the final throttle + * settings to skip cpu pulse. + */ + }; + }; + +Example: referring to Tegra132's "reg", "reg-names" and "throttle-cfgs" : + + soctherm@700e2000 { + compatible = "nvidia,tegra132-soctherm"; + reg = <0x0 0x700e2000 0x0 0x600 /* SOC_THERM reg_base */ + 0x0 0x70040000 0x0 0x200>; /* CCROC reg_base */; + reg-names = "soctherm-reg", "ccroc-reg"; + + throttle-cfgs { + /* + * When the "heavy" cooling device triggered, + * the HW will skip cpu clock's pulse in HIGH level + */ + throttle_heavy: heavy { + nvidia,priority = <100>; + nvidia,cpu-throt-level = <TEGRA_SOCTHERM_THROT_LEVEL_HIGH>; + + #cooling-cells = <1>; + }; + + /* + * When the "light" cooling device triggered, + * the HW will skip cpu clock's pulse in MED level + */ + throttle_light: light { + nvidia,priority = <80>; + nvidia,cpu-throt-level = <TEGRA_SOCTHERM_THROT_LEVEL_MED>; + + #cooling-cells = <1>; + }; + + /* + * If these two devices are triggered in same time, the HW throttle + * arbiter will select the highest priority as the final throttle + * settings to skip cpu pulse. + */ + + }; }; Example: referring to thermal sensors : @@ -62,6 +166,19 @@ Example: referring to thermal sensors : hysteresis = <1000>; type = "critical"; }; + + cpu_throttle_trip: throttle-trip { + temperature = <100000>; + hysteresis = <1000>; + type = "hot"; + }; + }; + + cooling-maps { + map0 { + trip = <&cpu_throttle_trip>; + cooling-device = <&throttle_heavy 1 1>; + }; }; }; }; diff --git a/Documentation/devicetree/bindings/thermal/qcom-tsens.txt b/Documentation/devicetree/bindings/thermal/qcom-tsens.txt new file mode 100644 index 000000000000..292ed89d900b --- /dev/null +++ b/Documentation/devicetree/bindings/thermal/qcom-tsens.txt @@ -0,0 +1,21 @@ +* QCOM SoC Temperature Sensor (TSENS) + +Required properties: +- compatible : + - "qcom,msm8916-tsens" : For 8916 Family of SoCs + - "qcom,msm8974-tsens" : For 8974 Family of SoCs + - "qcom,msm8996-tsens" : For 8996 Family of SoCs + +- reg: Address range of the thermal registers +- #thermal-sensor-cells : Should be 1. See ./thermal.txt for a description. +- Refer to Documentation/devicetree/bindings/nvmem/nvmem.txt to know how to specify +nvmem cells + +Example: +tsens: thermal-sensor@900000 { + compatible = "qcom,msm8916-tsens"; + reg = <0x4a8000 0x2000>; + nvmem-cells = <&tsens_caldata>, <&tsens_calsel>; + nvmem-cell-names = "caldata", "calsel"; + #thermal-sensor-cells = <1>; + }; diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt index efc3f3d293c4..ef473dc7f55e 100644 --- a/Documentation/thermal/sysfs-api.txt +++ b/Documentation/thermal/sysfs-api.txt @@ -49,6 +49,9 @@ temperature) and throttle appropriate devices. .bind: bind the thermal zone device with a thermal cooling device. .unbind: unbind the thermal zone device with a thermal cooling device. .get_temp: get the current temperature of the thermal zone. + .set_trips: set the trip points window. Whenever the current temperature + is updated, the trip points immediately below and above the + current temperature are found. .get_mode: get the current mode (enabled/disabled) of the thermal zone. - "enabled" means the kernel thermal management is enabled. - "disabled" will prevent kernel thermal driver action upon trip points @@ -95,6 +98,10 @@ temperature) and throttle appropriate devices. get_temp: a pointer to a function that reads the sensor temperature. This is mandatory callback provided by sensor driver. + set_trips: a pointer to a function that sets a + temperature window. When this window is + left the driver must inform the thermal + core via thermal_zone_device_update. get_trend: a pointer to a function that reads the sensor temperature trend. set_emul_temp: a pointer to a function that sets @@ -140,6 +147,18 @@ temperature) and throttle appropriate devices. Normally this function will not need to be called and the resource management code will ensure that the resource is freed. +1.1.7 int thermal_zone_get_slope(struct thermal_zone_device *tz) + + This interface is used to read the slope attribute value + for the thermal zone device, which might be useful for platform + drivers for temperature calculations. + +1.1.8 int thermal_zone_get_offset(struct thermal_zone_device *tz) + + This interface is used to read the offset attribute value + for the thermal zone device, which might be useful for platform + drivers for temperature calculations. + 1.2 thermal cooling device interface 1.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name, void *devdata, struct thermal_cooling_device_ops *) |