/* IBM_PROLOG_BEGIN_TAG */
/* This is an automatically generated prolog. */
/* */
/* $Source: src/include/usr/htmgt/htmgt_reasoncodes.H $ */
/* */
/* OpenPOWER HostBoot Project */
/* */
/* Contributors Listed Below - COPYRIGHT 2014,2015 */
/* [+] International Business Machines Corp. */
/* */
/* */
/* Licensed under the Apache License, Version 2.0 (the "License"); */
/* you may not use this file except in compliance with the License. */
/* You may obtain a copy of the License at */
/* */
/* http://www.apache.org/licenses/LICENSE-2.0 */
/* */
/* Unless required by applicable law or agreed to in writing, software */
/* distributed under the License is distributed on an "AS IS" BASIS, */
/* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or */
/* implied. See the License for the specific language governing */
/* permissions and limitations under the License. */
/* */
/* IBM_PROLOG_END_TAG */
#ifndef __HTMGT_REASONCODES_H
#define __HTMGT_REASONCODES_H
#include <hbotcompid.H>
namespace HTMGT
{
enum htmgtModuleId
{
HTMGT_MOD_LOAD_START_STATUS = 0x00,
HTMGT_MOD_WAIT_FOR_OCC_ACTIVE = 0x01,
HTMGT_MOD_WAIT_FOR_OCC_READY = 0x02,
HTMGT_MOD_MEMTHROTTLE = 0x03,
HTMGT_MOD_OCCMGR_SET_STATE = 0x04,
HTMGT_MOD_OCC_SET_STATE = 0x05,
HTMGT_MOD_PROCESS_OCC_RESET = 0x06,
HTMGT_MOD_OCC_RESET = 0x07,
HTMGT_MOD_BUILD_OCCS = 0x08,
HTMGT_MOD_PASS_THRU = 0x09,
HTMGT_MOD_CFG_FREQ_POINTS = 0x0A,
HTMGT_MOD_OCC_POLL = 0x76,
HTMGT_MOD_BAD_FRU_CALLOUTS = 0x7D,
HTMGT_MOD_MISMATCHING_SEVERITY = 0x7F,
HTMGT_MOD_READ_OCC_SRAM = 0x85,
HTMGT_MOD_SEND_OCC_CMD = 0x90,
HTMGT_MOD_WRITE_OCC_CMD = 0x91,
HTMGT_MOD_CHECK_OCC_RSP = 0x92,
HTMGT_MOD_PARSE_OCC_RSP = 0x94,
HTMGT_MOD_HANLDE_OCC_EXCEPTION = 0xE0,
HTMGT_MOD_ENABLE_OCC_ACTUATION = 0xE1,
};
enum htmgtReasonCode
{
HTMGT_RC_NO_ERROR = 0x00,
HTMGT_RC_INTERNAL_ERROR = HTMGT_COMP_ID | 0x01,
HTMGT_RC_THROTTLE_UTIL_ERROR = HTMGT_COMP_ID | 0x02,
HTMGT_RC_THROTTLE_INVALID_N = HTMGT_COMP_ID | 0x03,
HTMGT_RC_OT_THROTTLE_INVALID_N = HTMGT_COMP_ID | 0x04,
HTMGT_RC_OCC_NOT_READY = HTMGT_COMP_ID | 0x05,
HTMGT_RC_ATTRIBUTE_ERROR = HTMGT_COMP_ID | 0x06,
HTMGT_RC_NO_SUPPORT = HTMGT_COMP_ID | 0x0F,
HTMGT_RC_OCC_RESET = HTMGT_COMP_ID | 0x15,
HTMGT_RC_OCC_CRIT_FAILURE = HTMGT_COMP_ID | 0x16,
HTMGT_RC_SEND_FAIL = HTMGT_COMP_ID | 0x18,
HTMGT_RC_CHECKSUM_FAIL = HTMGT_COMP_ID | 0x19,
HTMGT_RC_OCC_CMD_FAIL = HTMGT_COMP_ID | 0x1B,
HTMGT_RC_INVALID_LENGTH = HTMGT_COMP_ID | 0x1C,
HTMGT_RC_OCC_ERROR_LOG = HTMGT_COMP_ID | 0x1D,
HTMGT_RC_INVALID_ROLE = HTMGT_COMP_ID | 0x22,
HTMGT_RC_INVALID_DATA = HTMGT_COMP_ID | 0x23,
HTMGT_RC_OCC_UNAVAILABLE = HTMGT_COMP_ID | 0x24,
HTMGT_RC_OCC_START_FAIL = HTMGT_COMP_ID | 0x25,
HTMGT_RC_OCC_UNEXPECTED_STATE = HTMGT_COMP_ID | 0x26,
HTMGT_RC_PRESENT_STATE_PROHIBITS = HTMGT_COMP_ID | 0x28,
HTMGT_RC_PARAMETER_OUT_OF_RANGE = HTMGT_COMP_ID | 0x29,
HTMGT_RC_OVERSUBSCRIBED = HTMGT_COMP_ID | 0x2D,
HTMGT_RC_TIMEOUT = HTMGT_COMP_ID | 0x35,
HTMGT_RC_COMMAND_IN_PROGRESS = HTMGT_COMP_ID | 0x36,
HTMGT_RC_INVALID_PARAMETER = HTMGT_COMP_ID | 0x45,
HTMGT_RC_MISSING_DATA = HTMGT_COMP_ID | 0x4F,
HTMGT_RC_ECMD_DBUF_COPY_FAIL = HTMGT_COMP_ID | 0x53,
HTMGT_RC_TARGET_NOT_FUNCTIONAL = HTMGT_COMP_ID | 0x54,
HTMGT_RC_OCC_MASTER_NOT_FOUND = HTMGT_COMP_ID | 0x55,
HTMGT_RC_OCC_RESET_THREHOLD = HTMGT_COMP_ID | 0x56,
HTMGT_RC_PCAP_CALC_COMPLETE = HTMGT_COMP_ID | 0xB9,
HTMGT_RC_ENERGYSCALE_FFDC = HTMGT_COMP_ID | 0xFD,
};
};
#endif
|