Commit message (Collapse)AuthorAgeFilesLines
* Add SBE Arch dump area for both OPAL & PHYPDean Sanner2020-01-081-18/+28
| | | | | | | | | | | | | | | Currently Hostboot only sets up the architected dump capture on the SBE for OPAL based systems. This commit adds the setup to PHYP based systems as well. Change-Id: I96271a57f7c15c571495ed56ea72dbeeebab8d94 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/88095 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: MURULIDHAR NATARAJU <murulidhar@in.ibm.com> Reviewed-by: Daniel M Crowell <dcrowell@us.ibm.com>
* Automatically include config.hDan Crowell2019-12-064-5/+1
| | | | | | | | | | | | | | | | | | Rather than having to remember to include config.h anywhere we reference a CONFIG variable (and usually forgetting), this adds it to the default compiler flags so that it gets included in every source file we build. Change-Id: I53622ab4d46c55d942e98cae6ec03049fd5b3d08 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/87475 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Zachary Clark <zach@ibm.com> Reviewed-by: Roland Veloz <rveloz@us.ibm.com> Reviewed-by: Christian R Geddes <crgeddes@us.ibm.com> Reviewed-by: Nicholas E Bofferding <bofferdn@us.ibm.com>
* Fix auto-arming NVDIMMs for ESS systemsCorey Swenson2019-11-191-2/+16
| | | | | | | | | | | | | | | | | | | ESS requires HB to arm the NVDIMMs during IPL after PM complex is started. Requires moving the nvdimmArm() and associated functions from nvdimm_rt.C to nvdimm.C. Change-Id: Ie7fd08b27ad7959b21086f0f291764c2156e5bd9 CQ:SW479909 CMVC-Prereq:1096403 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/86489 Reviewed-by: Matt Derksen <mderkse1@us.ibm.com> Reviewed-by: Roland Veloz <rveloz@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M Crowell <dcrowell@us.ibm.com>
* Remove Unused clearPoreBars function in Istep 21.3Bill Hoffa2019-09-251-94/+1
| | | | | | | | | | | | | | | | - This functionality was never used so remove it Change-Id: I2885be14c4bbf68e322a8a52f9364210e6943ca9 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/84183 Reviewed-by: Daniel M Crowell <dcrowell@us.ibm.com> Reviewed-by: Ilya Smirnov <ismirno@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Dean Sanner <dsanner@us.ibm.com> Reviewed-by: Christian R Geddes <crgeddes@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: William G Hoffa <wghoffa@us.ibm.com>
* NVDIMM: Load warning thresholds, after FW_UPDATE, on every IPLCorey Swenson2019-08-261-0/+3
| | | | | | | | | | | | | | | | See defect for register list and hard-coded values Change-Id: Ibc32ddfcb4719388dd744aa946df62e27066a05c CQ:SW472435 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/82348 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Glenn Miles <milesg@ibm.com> Reviewed-by: Matt Derksen <mderkse1@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Roland Veloz <rveloz@us.ibm.com> Reviewed-by: Daniel M Crowell <dcrowell@us.ibm.com>
* Secureboot: Enable verifying OPAL Payload before starting instructionsMike Baiocchi2019-07-261-2/+2
| | | | | | | | | | | | | | | | | For Enterprise systems that will boot OPAL, hostboot code will now securely verify the OPAL payload before starting instructions if secureboot is enabled. Change-Id: I1c392758f90c4a886d2a7731d78980bdaa21837f RTC:187304 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/80818 Reviewed-by: Ilya Smirnov <ismirno@us.ibm.com> Reviewed-by: Zachary Clark <zach@ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: William G Hoffa <wghoffa@us.ibm.com>
* OPAL/MPIPL: Processor Dump Area Table interfacesRaja Das2019-03-211-2/+20
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | This patch adds support to collect processor architected register data. SBE <--> Hostboot : ------------------- During first boot, hostboot reserves memory to copy architected register data by SBE and sends address to each SBE (see commit 9f49d11b). During MPIPL SBE collects architected register data and copies to reserved memory. Hostboot <--> Hypervisor : -------------------------- HDAT/SPIRAH has new ntuple (Processor Dump Area) to pass various architected register data. During IPL/runtime hypervisor reserves memory for architected register data and updates SPIRAH. During MPIPL (istep 14.8), hostboot converts SBE formated architected registers data to HDAT format and copies to hypervisor reserved memory. It uses NACA/SPIRAH pointers to get hypervisor reserved memory details. Hostboot has to update SPIRAH ntuple after loading new LID to memory. Hence this patch introdues below new attributes: - PDA_CAPTURED_THREAD_REG_ARRAY_ADDR - PDA_CAPTURED_THREAD_REG_ARRAY_SIZE - PDA_THREAD_REG_ENTRY_SIZE - PDA_THREAD_REG_STATE_ENTRY_FORMAT Change-Id: Idc7489e8cf6fc68fe80f028ba6deb97aa72486bf CC: Sampa Misra <sampmisr@in.ibm.com> CC: Daniel M. Crowell <dcrowell@us.ibm.com> Signed-off-by: Vasant Hegde <hegdevasant@linux.vnet.ibm.com> Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/61627 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Update UCD class member variables and functionsMike Baiocchi2019-03-201-1/+1
| | | | | | | | | | | | | | | | | This commit makes Ucd class member variables to hold the I2C information stored in an attribute of the UCD. It also makes updateUcdFlash() a member function. Change-Id: I66221f0bd1b7dbe82ed4547c0635fbf99628471b RTC:205979 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/74674 Reviewed-by: Ilya Smirnov <ismirno@us.ibm.com> Reviewed-by: Matthew Raybuck <matthew.raybuck@ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* UCD flash update invokerNick Bofferding2019-03-201-27/+83
| | | | | | | | | | | | | | | | | | Implements the main algorithm for finding applicable UCDs to perform flash update on and walking the UCD flash image table of contents to find the image associated with a UCD. Also adds a check to skip the update if simics is running. RTC: 201991 Change-Id: Ib35abec2f0a2ed22ae8d41a2acecd146f699bc43 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/73484 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Ilya Smirnov <ismirno@us.ibm.com> Reviewed-by: Matthew Raybuck <matthew.raybuck@ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Support UCD discoveryNick Bofferding2019-03-151-8/+38
| | | | | | | | | | | | | | | | | | - Added new attribute to indicate if target should be assumed present - Added that attribute to SP/BMC/UCD targets - Check for assumed present UCDs in discover targets - Iterate through every UCD for data flash update RTC: 201991 Change-Id: Ia535a58ea0355582621a23d3c1b50b2417ad362f Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/73047 Reviewed-by: Matthew Raybuck <matthew.raybuck@ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* UCD Flash Update: Support I2C SMBUS operations for UCD flash updateNick Bofferding2019-03-081-1/+10
| | | | | | | | | | | | | | | | | - Adds I2C SMBUS operations for UCD flash update - Creates UCD component ID + trace name - Creates stub for UCD flash update entry point Change-Id: Id75cdd137b5a4924998c04bdbdce9218610a4906 RTC: 201992 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/72229 Reviewed-by: Ilya Smirnov <ismirno@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Matthew Raybuck <matthew.raybuck@ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Move nvdimm_update call to istep 21.1Matt Derksen2019-03-014-2/+127
| | | | | | | | | | | | | | | | | istep20 is not called on FSP-based systems, so the update call needed to be moved to 21.1. This was selected because it requires lids. Change-Id: I2378eb1629e982913a3abe8b652b436edd692439 RTC: 201197 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/71859 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Reviewed-by: Corey V. Swenson <cswenson@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* HB:Cme fir attribute reset fixPrasad Bg Ranganath2019-02-221-1/+8
| | | | | | | | | | | | CQ:SW455727 Change-Id: I854779403ab138f193ad7fc3ff188b4e7d48388e Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/72122 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Prem Shanker Jha <premjha2@in.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Support reading UCD flash update LIDsNick Bofferding2019-02-184-2/+162
| | | | | | | | | | | | | | | | | | | - Added support to read a single LID container and securely verify it - Added new compile flag CONFIG_UCD_FLASH_UPDATES to enable/disable future TI UCD9090/UCD90120A flash updates - Created shell function to hold the UCD flash update logic Change-Id: I94f3e43558af5d7951febdf6ff0685c120d2db0e RTC: 201992 CMVC-Prereq: 1076388 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/71945 Reviewed-by: Marshall J. Wilks <mjwilks@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Reviewed-by: Ilya Smirnov <ismirno@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Close windows where Hostboot HRMOR is not available to FSPNick Bofferding2018-10-121-0/+15
| | | | | | | | | | | | | | | | | | | There are certain small time windows where the core scratch register, which holds the Hostboot load address for FSP to read in order to dump Hostboot, is cleared during winkle. This change caches the Hostboot load address in a processor attribute that FSP can read/use in the event it happens to request a dump in the window where the core scratch register is not valid. Change-Id: I776df5e64f4d8ad382392662d08ee349661ba78a CQ: SW444212 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/66664 Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Reviewed-by: Ilya Smirnov <ismirno@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Shutdown: Move attribute sync to shutdown handlerNick Bofferding2018-10-011-0/+8
| | | | | | | | | | | | | | | Moved synching attributes into an attribute resource provider shutdown path to avoid race conditions along the shutdown path where a normal error path coupled with parallel shutdown leads to FSP attribute sync errors. Change-Id: Ibdb828f8132da1e251f880ef0e7d4fea2e4619a3 CQ: SW443737 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/66431 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* MPIPL: Update MDRT count only if its validVasant Hegde2018-09-281-1/+5
| | | | | | | | | | | | | | | | | | | | | | | | Commit 529bf93 added new attribute to save MDRT count (MPIPL_HB_MDRT_COUNT). This commit un-conditionally updates MDRT count in call_host_runtime_setup(). At present OPAL doesn't support MPIPL and hence its not updating MDRT ntuple in SPIRAH...resulting in writeActualCount() to fail. And we endup in system terminate state (at least in FSP system). Lets make sure attribute contains valid MDRT count before calling saveActualCount(). Change-Id: I8d25a274d65034bca392137e4f48b8a127fa4ee0 Fixes: 529bf93 (Use Attr to Save/Fetch MDRT Count) CC: Raja Das <rajadas2@in.ibm.com> Signed-off-by: Vasant Hegde <hegdevasant@linux.vnet.ibm.com> Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/66474 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Dean Sanner <dsanner@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Clear out HOMER attributes and reset PM in PHYP modeDan Crowell2018-09-181-0/+28
| | | | | | | | | | | | | | | | | | | | During the IPL, Hostboot will initialize part of the PM Complex and setup the HOMER memory spaces. At runtime, PHYP will reinit the complex with its own memory spaces. This change explicitly resets the complex and clears any related HOMER attributes before jumping to PHYP so that the first call at runtime starts completely fresh. Change-Id: I540b79143d5fbba876ffc0ac72721639153a1cfa CQ: SW444669 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/65983 Reviewed-by: Matt Derksen <mderkse1@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Corey V. Swenson <cswenson@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Additional tracing for shutdown eventsMatt Derksen2018-09-121-1/+1
| | | | | | | | | | | | | | | | | Hit an issue where a shutdown was called but all that is traced is a msgQ pointer. These traces should help associate the msgQ pointer to an actual task being shutdown. Change-Id: Ic22fdde1a146eec90f26d557e8af1ddec3c85c4e CQ:SW443508 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/65464 Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Corey V. Swenson <cswenson@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Turn off core xstop escalalation on slave nodes prior payload handoffChristian Geddes2018-09-101-178/+15
| | | | | | | | | | | | | | | | | | | | | There was a bug in the code where we only were turning off core xstop escalation on the master node. This is because we were not using IPC to tell slave nodes they also need to do this. This commit re-adds the enableCoreCheckstop function to istep21 and adds it to part of the IPC_START_PAYLOAD message handler so this will happen prior to shutdown on all nodes. Change-Id: I0b601f379635107c851d6fc723b75a0ba21d1016 CQ: SW444801 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/65768 Reviewed-by: Dean Sanner <dsanner@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com>
* Run INT scominit on all nodes in multinode systemsDean Sanner2018-09-081-10/+8
| | | | | | | | | | | | | | | | There was a bug in the code where it was only setting up the msg queue/task for the INT scominit on the master node. Moved setup into callShutdown, which runs on all nodes. Change-Id: I5c98c588cab6627d9e87232e89aa333cf8a0aa05 CQ:SW444995 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/65865 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Enable PM Malf Alert Handling & PM Complex FFDC to HOMERAmit Tendolkar2018-08-011-0/+7
| | | | | | | | | | | | | | | | | | | 1. Enable ATTR_PM_MALF_ALERT_ENABLE so that alerts due to a PM Complex failure are sent to PHYP and related callouts, etc by PRD are enabled. This is enabled only for PHYP loads. 2. Enable ATTR_PM_RESET_FFDC_ENABLE so that on a PM Complex Reset triggered due to PM Errors (e.g. Malf alert, etc.), PM Complex FFDC is captured and stored in the HOMER to enable debug. Change-Id: I2c0b753e461a59e12f99ef029702759f508904cb CQ: SW436197 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/62727 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Use Attr to Save/Fetch MDRT CountRaja Das2018-07-201-0/+12
| | | | | | | | | | | | | | | | | | | | MDRT count is saved out into an attribute in istep14 and the same is fetched out in istep21 for Phyp as well as Opal(ZZ-L) system. Added libruntime.so to istep14, Since Dump relies upon runtime module Moved 'useRelocatedPayloadAddr' setting to call_host_mpipl_service(), So that we have everything set before calling doDumpCollect() Change-Id: I5d30135d86a1477a68509aaff0516efb4d620410 Signed-off-by: Vasant Hegde <hegdevasant@linux.vnet.ibm.com> Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/58636 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Secure Boot: Copy PHyp secure header into standard reserved memory areaNick Bofferding2018-06-291-23/+12
| | | | | | | | | | | | | | | | This change alters where Hostboot copies the Phyp secure header; instead of placing it in front of PHYP (PHyp HRMOR-4k), it instead redirects it to the standard reserved memory area. By doing this, we prevent it from unintentionally ending up in mirrored memory. Change-Id: I0b228b4a748310eba2b580efe2f191adca0d05e3 CQ: SW435712 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/61525 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Fix bugs in core checkstop escalation manipulation during HBChristian Geddes2018-06-141-1/+1
| | | | | | | | | | | | | | | | | | | There was a bug where in fused mode we are not also setting the 2nd half of the fused core to have the appropriate scom values in the fir action registers. Also we were not re-applying the desired values back to the core fir action registers at the end of hostboot because of a simple bug. Change-Id: I32ae9c7839e27392cfdf0401d008a12941804beb CQ: SW432725 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/60439 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Elizabeth K. Liner <eliner@us.ibm.com> Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Secure Boot: Set trusted boot enabled in HDAT considering all nodesIlya Smirnov2018-05-312-0/+108
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | This change implements reporting of trusted boot status to HDAT considering all nodes of the system. To avoid inter-node communication, the check is done after the HDAT TPM info is populated for all nodes. The logic goes through all TPM Info HDAT records (for each node) and checks whether the master TPM on each node is present and functional. The result is aggregated into the trusted boot enabled bit on the master node. The check is done after the separators have been extended into TPM; this allows each primary TPM more chances to fail before we say that it's functional. Trusted boot enabled bit is reported as 1 if ALL primary TPMs on ALL booting nodes are present and functional. It is reported as 0 if at least one primary is not present or not functional. Change-Id: I926532efe85b33e95e50d84b0b5e4554852f0601 RTC: 191194 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59279 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Set up core checkstop escalation using HWPElizabeth Liner2018-05-223-11/+37
| | | | | | | | | | | | | | | | This commit creates the hostboot functionality around the p9_core_checkstop_handler HWP. At various points in the IPL when we want to turn off unit checkstops for system checkstops, and then later restore them, we call this HWP. Change-Id: I6f69a9c3a88707f29e4b86e9f4e3b3bd3dfd76b7 RTC: 147565 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56430 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* istep21: Keep the watchdog running into the host payloadWilliam A. Kennington III2018-05-191-29/+3
| | | | | | | | | | | | | | | | | | | | Skiboot has supported and enabled the IPMI watchdog for some time now. We can now assume that it is safe keep the watchdog running when transitioning to the skiboot payload as it will handle it during startup. Resolves #137 Signed-off-by: William A. Kennington III <wak@google.com> Change-Id: I2308c2b69da1f971a2356caa3cbd318342c2e89f Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/58548 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Verify frequency attributes across nodes to match with that of master nodeSwathi Madhuri Bhattiprolu2018-05-164-0/+901
| | | | | | | | | | | | | | | | | | | | | -Existing code ensures consistency of frequency data across all modules in istep6.12. -In a multi-drawer config this data needs to be consistent across all drawers. -Master drawer sends the frequency data to all the other via IPC mechanism. -This data is compared and error is returned if there is a mismatch. Change-Id: Ia1daf1f0eeb90fbafb68417b979488b040efe535 RTC:158036 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57542 Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Roland Veloz <rveloz@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Get Final HDAT Size from PAYLOAD's SPIRA sectionMike Baiocchi2018-05-081-10/+43
| | | | | | | | | | | | | | | | | This commit retrieves the amount of space the PAYLOAD has reserved for the HDAT content in its SPIRA section. It then uses this size when copying the HDAT from the temporary location (where the FSP put it with DMAs-via-TCEs) to its final location. Change-Id: I430a78a1655db85f448b3f5c30e6a83f5be4b1f6 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/58261 Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* MPIPL: Update MDRT count for FSP based OPAL systemVasant Hegde2018-05-071-9/+7
| | | | | | | | | | | | | | | | | At present hostboot updates MDRT actual count after MPIPL for PHYP systems only. Soon we are going to support MPIPL on FSP based OPAL system as well. Lets enable MDRT count update for FSP based OPAL system as well. Change-Id: Ibc16bf9c98786a36c2c38755da507a6e001e44db Signed-off-by: Vasant Hegde <hegdevasant@linux.vnet.ibm.com> Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/58166 Reviewed-by: NAGENDRA K. GURRAM <nagendra.g@in.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Sachin Gupta <sgupta2m@in.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Move VPD cache invalidation in mfgmode after we save it for HBRTDan Crowell2018-04-191-10/+13
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Inside call_host_runtime_setup() there is a call to VPD::goldenCacheInvalidate(). This function invalidates our VPD cache in PNOR in mfg-mode in order to allow manufacturing to modify serial numbers at runtime and have those settings take effect on the next boot. This has been in place since early P8 OpenPOWER. In that same function is a call to RUNTIME::populate_hbRuntimeData(). This is where we copy the Hostboot data out into mainstore for HBRT to use later on. One of those pieces of data is the VPD cache. In January a fix went in for a different issue that moved where populate_hbRuntimeData() was run, putting it *after* we clear it in mfgmode. Obviously that isn't going to work so well... This commit moves the invalidation later in the function so that it is after we save off the cache again. Change-Id: Idb482b583ecdb7bb8abcb617bae4ae786c110fea CQ: SW424124 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57469 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Marshall J. Wilks <mjwilks@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Reviewed-by: Corey V. Swenson <cswenson@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Use HRMOR-relative addresses for temporary PAYLOAD and HDAT memoryMike Baiocchi2018-04-181-6/+9
| | | | | | | | | | | | | | | | | | | | The FSP DMAs-via-TCEs the PAYLOAD and HDAT sections into HRMOR-relative memory on the master node. However, istep21's verifyAndMove() function was not using HRMOR-relative physical addresses and failed when node0 was not configured. These changes should address this and similar code using these address spaces. Change-Id: Idba95a97de9906ba6c0203f797b526eab694b8cf CQ:SW425130 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57357 CI-Ready: Michael Baiocchi <mbaiocch@us.ibm.com> Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Multinode SBE Window SupportJaymes Wilks2018-04-131-15/+28
| | | | | | | | | | | | | | | | | | | Code for SP ATTN, COMM, and SBE FFDC areas has been extended to all chips/nodes. The COMM area base address calculation is now updated to use the lowest addressable location for the master node. Change-Id: Ib02e62958a520c60e4bcc5bd9d4c4257893adbd9 RTC:189038 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56614 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Revert "Verify frequency attributes across nodes"SWATHI M. BHATTIPROLU2018-04-094-843/+0
| | | | | | | | | | | | This reverts commit 571e1d84dfe50aaa674aa7e33abb75868b432d78. Change-Id: I8720246ef94be07ce0a37151b7209c8080320d59 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56933 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Verify frequency attributes across nodesSwathi Madhuri Bhattiprolu2018-04-054-1/+844
| | | | | | | | | | | | | | | | | | | | | | | -Existing code ensures consistency of frequency data across all modules in istep6.12. -In a multi-drawer config this data needs to be consistent across all drawers. -Master drawer sends the frequency data to all the other via IPC mechanism. -This data is compared and error is returned if there is a mismatch. Change-Id: I922d32456c9d3c4e53dae528f088dbb013c3ded9 RTC:158036 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/54825 CI-Ready: SWATHI M. BHATTIPROLU <bhmadhur@in.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Richard Ward <rward15@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Close and Disable TCEs on Non-Master NodesMike Baiocchi2018-03-291-3/+123
| | | | | | | | | | | | | | | | | | During istep21.1 this commit sends a message to all non-Master nodes to close and disable their TCEs using the ipc mailbox interface to the FSP. Change-Id: I5575228c9f237025a48e0aeca23e741724ec7886 RTC:187335 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56269 CI-Ready: Michael Baiocchi <mbaiocch@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Setup Node-Level Attributes for Multinode TCE SupportMike Baiocchi2018-03-261-0/+3
| | | | | | | | | | | | | | | | | | | | | This commit establishes a TCE Table and allocates the necessary TCEs for each node in a multinode (ie, Fleetwood) system. It then sets the corresponding node-level TCE attributes such that the FSP can use these TCEs for PSI Diagnostics and DMAing-via-TCEs the PAYLOAD and HDAT content. Change-Id: Ibd06675ea68a9c630987765b51fdd9db631f6425 RTC:187335 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/56129 CI-Ready: Michael Baiocchi <mbaiocch@us.ibm.com> Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: Marshall J. Wilks <mjwilks@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Flush TMP Daemon Traces Prior to ShutdownIlya Smirnov2018-03-151-2/+4
| | | | | | | | | | | | | | | | | | We need to make sure that the TMP daemon message queue is flushed prior to shutting down the daemon. A way to do that is to send the extend separator message synchronously. That will allow for all of the traces to be logged prior to shutdown. Change-Id: Ia025e6cccbe34bbfc086f2b7213e10d4b8cf14e7 RTC:188959 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/55792 Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* changes to move configureHbrt target type to IPC path to run on slave nodesPrachi Gupta2018-03-071-8/+0
| | | | | | | | | | | | | Change-Id: Iee5e5231851e6f6389f83607da35121dbfe5a0b9 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/54855 Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Richard J. Knight <rjknight@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Support sending chip info to SBEs on multinodeDean Sanner2018-02-281-56/+8
| | | | | | | | | | | | | | | | | | | | Existing code didn't support collecting the present chips on all nodes (Hostboot instances) and updating all SBEs with a system wide view. For non multi drawer configs it will just update based on HB instance view. For multi drawer configs the other hostboot instances will be queried for their configs, aggregated, and then informed of the system wide view via IPC commnuication. Change-Id: I45c5673df26f940de212cbe2b54525e32c9147ab Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/53603 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Dean Sanner <dsanner@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Extend PM Reset flow to collect PM FFDC to HOMERAmit Tendolkar2018-02-171-1/+0
| | | | | | | | | | | | | | | | | | | | | | | | | | | - extend the base flow to ensure ffdc gets collected to homer - revise error xmls - misc changes to handle pm recovery flow triggered via Malf Alert Key_Cronus_Test=PM_REGRESS Change-Id: I12148ed227efe4613332ae76ff142c1d82855f20 RTC: 153979 CQ: SW416537 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/53522 Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: RANGANATHPRASAD G. BRAHMASAMUDRA <prasadbgr@in.ibm.com> Reviewed-by: Prem Shanker Jha <premjha2@in.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: HWSV CI <hwsv-ci+hostboot@us.ibm.com> Tested-by: PPE CI <ppe-ci+hostboot@us.ibm.com> Tested-by: Hostboot CI <hostboot-ci+hostboot@us.ibm.com> Tested-by: Cronus HW CI <cronushw-ci+hostboot@us.ibm.com> Reviewed-by: Gregory S. Still <stillgs@us.ibm.com> Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/53533 Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Tested-by: Christian R. Geddes <crgeddes@us.ibm.com>
* Remove all explicit calls to special_wakeup from hostboot codeChristian Geddes2018-02-161-61/+0
| | | | | | | | | | | | | | The only time that special wakeup should be called on the hostboot platform is when it is called by other HWPs. PM_RESET will only enable special wakeup if the SKIP_WAKEUP attribute is set to 0 Change-Id: Ib9939eae857fa5113a876a717f8169e150b78318 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/54148 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Find location of HDAT relocation dynamically from PAYLOADMike Baiocchi2018-02-081-11/+22
| | | | | | | | | | | | | | | | | | | This commit looks at the NACA structure in the Primary PAYLOAD lid to determine the final destination of the HDAT structure that the FSP loaded into a temporary memory space using TCEs. Change-Id: I82b94f5fc133e4222d4efdcc7444012d7bcb5166 RTC:168745 Backport:release-fips910 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/53564 Reviewed-by: ILYA SMIRNOV <ismirno@us.ibm.com> Reviewed-by: Marshall J. Wilks <mjwilks@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Fixes for multinode istep 21.1Dean Sanner2018-02-061-49/+44
| | | | | | | | | | | | | | | -Reordered start_payload to ensure that common things like disabling special wakeup, closing down SBE windows, core xstop, and clearing PM bars are executed as part of our shutdown path -Due to above, needed to correct shared libs loaded on non master HB instance -Added back in the P8 code to pass the payload base to slave HB Instances on populate attr IPC message Change-Id: I5371b9daf7a4e1aadd1743badcd4219604a38ce7 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/53343 Tested-by: William G. Hoffa <wghoffa@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Handle INTRP SHUT_DOWN message in MBOX IPC msg_hdlrBill Hoffa2018-02-061-4/+4
| | | | | | | | | | | | | | | | | - Messages sent to MBOX during INTRP shutdown causing IPC Invalid Message Data Errorlogs - Improve Inadvertent IPC Message Handling FFDC Change-Id: Idccad59664e7c95bf8a8618646a13b28c71b4ac7 CQ: SW415386 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/52981 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Verify ComponentID and Extend PAYLOADMike Baiocchi2018-02-011-6/+51
| | | | | | | | | | | | | | | | | | | While verifying the PAYLOAD in memory before moving it to its final location, this commit parses the PAYLOAD's header and verifies that it has the correct componentId. It also extends the PAYLOAD information to the TPM. Change-Id: Ie333d1ba5919b36919b207f25ad60806359ed710 RTC:168745 Backport: release-fips910 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/52837 Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Stephen M. Cprek <smcprek@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Secure Boot: Skip OPAL VerificationMike Baiocchi2018-01-311-1/+1
| | | | | | | | | | | | | | | | | | This commit will skip verifying the OPAL Payload in istep 21.1 after the HDAT FSP component has loaded it into memory. The OPAL payload will still be loaded in the right memory location and the IPL will continue. Change-Id: Ib0e6b705264bf3f3612a2563fd4177ee57aaa3e7 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/52960 Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: Marshall J. Wilks <mjwilks@us.ibm.com> Reviewed-by: Stephen M. Cprek <smcprek@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Enable TCEs as the default on FSP-based systemsMike Baiocchi2018-01-261-17/+12
| | | | | | | | | | | | | | | | | | This would enable TCEs on all FSP-based systems by setting the default value of ATTR_USE_TCES_FOR_DMAS to '1'. It can be over- written to 0, if necessary. Change-Id: Id30101256dfd862dae362b97b71df96def37cf03 RTC: 168745 CMVC-Prereq: 1043605 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/52549 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Stephen M. Cprek <smcprek@us.ibm.com> Reviewed-by: Marshall J. Wilks <mjwilks@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com>
* Move closing all unsecure memory regions to 21.3Stephen Cprek2018-01-222-28/+25
| | | | | | | | | | | | | | | | | | | | Current windows that are left open at end of IPL - SBE FFDC - CPU Controls SP ATTN area - 0-64MB for SP ATTN Change-Id: I887fc63bcc70f2351530741bd251db12732a5948 RTC:168745 Backport:release-fips910 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/52045 Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Reviewed-by: Nicholas E. Bofferding <bofferdn@us.ibm.com> Reviewed-by: Marshall J. Wilks <mjwilks@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>