summaryrefslogtreecommitdiffstats
path: root/src/usr/htmgt/runtime
Commit message (Collapse)AuthorAgeFilesLines
* Make RT_TARG id generation code common between IPL time and runtimeChristian Geddes2020-01-221-2/+2
| | | | | | | | | | | | | | | | | For axone we are writing the OMI mmio bars into hdat so the hypervisor know how to talk to the devices. IPL code needs to be able to lookup the hbrt-style ids so we can use them to make hdat entries that the hypervisor will be able to associate targets with. This commit also move rt_targeting.H to the correct include directory and updates everywhere that it is included. Change-Id: I31deaa1a9c5a7523622a8b3b12ad459e2b2feed3 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/80419 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M Crowell <dcrowell@us.ibm.com>
* Add consistent enter-exit traces for all runtime interfacesDan Crowell2018-10-021-0/+9
| | | | | | | | | | | | | | | | | | Created a new 'HBRT' trace buffer that is exclusively used to bound the external calls into our runtime image. Modified the return code values to be the reasoncode of the error log we commit instead of a generic '-1' value that is not very helpful. Change-Id: Id41288ea1903bf6d11e967fcb10a8184153943c8 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/64871 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Brian J. Stegmiller <bjs@us.ibm.com> Reviewed-by: Matt Derksen <mderkse1@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
* Check for pending OCC messages on HBRT start in OpenPOWERBrian Bakke2018-04-171-2/+34
| | | | | | | | | | | | | | | | | | | The OCC will set an interrupt for the Host to look for a pending message/action. If opal-prd is not running at the time that this interrupt happens, HTMGT will never see the message. Therefore we need to have HTMGT explicitly check for anything pending any time HBRT starts up. Change-Id: Iaae075ae6828a9de5a7bd5afe55c541b0076f2d2 RTC: 187912 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/57175 Reviewed-by: Christopher J. Cain <cjcain@us.ibm.com> Reviewed-by: Matt Derksen <mderkse1@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Connect get_lid_list interface function in UtilLidMgrCorey Swenson2017-06-231-1/+0
| | | | | | | | | | | | | Change-Id: I415b85fd3bf5b1aa4f9caeca5d689e54bcbb1b86 CQ:SW393002 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/42315 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Matt Derksen <mderkse1@us.ibm.com> Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* Clean up OCC and enable HTMGTCorey Swenson2017-05-102-2/+165
| | | | | | | | | | | | | Change-Id: I0903f4bd504589d4d5931b4b3b6206664f39b119 RTC:171441 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/39736 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Reviewed-by: Michael Baiocchi <mbaiocch@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Sheldon R. Bailey <baileysh@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
* HTMGT support for Pstate Table BiasingChris Cain2015-08-181-2/+2
| | | | | | | | | | Change-Id: I96aff34fb9b588d8546575b77655a6cf167469fb RTC: 128436 Reviewed-on: http://gfw160.aus.stglabs.ibm.com:8080/gerrit/18789 Tested-by: Jenkins Server Tested-by: Jenkins OP Build CI Tested-by: Jenkins OP HW Reviewed-by: A. Patrick Williams III <iawillia@us.ibm.com>
* HTMGT Pstate supportDoug Gilbert2014-12-131-2/+2
| | | | | | | | | Change-Id: I68388d448afa027439c78f654c00ca2f9904d65e RTC: 114284 Reviewed-on: http://gfw160.aus.stglabs.ibm.com:8080/gerrit/14191 Reviewed-by: Christopher Cain <cjcain@us.ibm.com> Tested-by: Jenkins Server Reviewed-by: A. Patrick Williams III <iawillia@us.ibm.com>
* HTMGT add required HW procedures and setup HTMGT componentDoug Gilbert2014-11-121-0/+40
Change-Id: Ie61cf3d076dec6de23028d7a816c8719f66fb4ab RTC:115384 Reviewed-on: http://gfw160.aus.stglabs.ibm.com:8080/gerrit/13477 Tested-by: Jenkins Server Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com> Reviewed-by: Christopher Cain <cjcain@us.ibm.com> Reviewed-by: A. Patrick Williams III <iawillia@us.ibm.com>