diff options
-rw-r--r-- | src/import/chips/ocmb/common/procedures/xml/error_info/pmic_errors.xml | 89 |
1 files changed, 0 insertions, 89 deletions
diff --git a/src/import/chips/ocmb/common/procedures/xml/error_info/pmic_errors.xml b/src/import/chips/ocmb/common/procedures/xml/error_info/pmic_errors.xml index 843a92812..fd80afa98 100644 --- a/src/import/chips/ocmb/common/procedures/xml/error_info/pmic_errors.xml +++ b/src/import/chips/ocmb/common/procedures/xml/error_info/pmic_errors.xml @@ -134,24 +134,6 @@ </hwpError> <hwpError> - <rc>RC_PMIC_BIAS_VOLTAGE_PAST_THRESHOLD</rc> - <description> - The bias voltage provided exceeded the 10%% change limit. Use -f argument to override. - </description> - <ffdc>TARGET</ffdc> - <ffdc>RAIL</ffdc> - <ffdc>PERCENT</ffdc> - <callout> - <procedure>CODE</procedure> - <priority>MEDIUM</priority> - </callout> - <callout> - <target>TARGET</target> - <priority>HIGH</priority> - </callout> - </hwpError> - - <hwpError> <rc>RC_PMIC_DIMM_SPD_4U</rc> <description> The module_height attribute SPD of this DIMM was read as 4U. @@ -168,75 +150,4 @@ </callout> </hwpError> - <hwpError> - <rc>RC_PMIC_BIAS_VOLTAGE_OUT_OF_RANGE</rc> - <description> - The target voltage supplied to the BIAS operation was out of range for the PMIC. - </description> - <ffdc>TARGET</ffdc> - <ffdc>VOLTAGE</ffdc> - <ffdc>MIN</ffdc> - <ffdc>MAX</ffdc> - <ffdc>RAIL</ffdc> - <callout> - <procedure>CODE</procedure> - <priority>MEDIUM</priority> - </callout> - <callout> - <target>TARGET</target> - <priority>HIGH</priority> - </callout> - </hwpError> - - <hwpError> - <rc>RC_PMIC_NO_PMIC_SPECIFIED</rc> - <description> - The PMIC ENUM ID provided to the procedure was unknown - </description> - <ffdc>TARGET</ffdc> - <ffdc>PMIC_ID</ffdc> - <callout> - <procedure>CODE</procedure> - <priority>MEDIUM</priority> - </callout> - <callout> - <target>TARGET</target> - <priority>HIGH</priority> - </callout> - </hwpError> - - <hwpError> - <rc>RC_PMIC_NO_SETTING_SPECIFIED</rc> - <description> - The PMIC SETTING ENUM provided to the procedure was unknown - </description> - <ffdc>TARGET</ffdc> - <ffdc>SETTING_ID</ffdc> - <callout> - <procedure>CODE</procedure> - <priority>MEDIUM</priority> - </callout> - <callout> - <target>TARGET</target> - <priority>HIGH</priority> - </callout> - </hwpError> - - <hwpError> - <rc>RC_PMIC_NO_UNIT_SPECIFIED</rc> - <description> - The PMIC UNIT ENUM provided to the procedure was unknown - </description> - <ffdc>TARGET</ffdc> - <ffdc>UNIT_ID</ffdc> - <callout> - <procedure>CODE</procedure> - <priority>MEDIUM</priority> - </callout> - <callout> - <target>TARGET</target> - <priority>HIGH</priority> - </callout> - </hwpError> - </hwpErrors> |