authorZane Shelley <zshelle@us.ibm.com>2018-01-04 16:46:17 -0600
committerZane C. Shelley <zshelle@us.ibm.com>2018-01-17 11:16:03 -0500
commitd1c569251281f56eadd25f1c81d82da1b3c242d9 (patch)
tree04c3c74855301d881842a7d7ac7f9ec4262f5b2e /src
parentdf5241f06802858615a8809dbc17096228e36ba9 (diff)
downloadtalos-hostboot-d1c569251281f56eadd25f1c81d82da1b3c242d9.tar.gz
talos-hostboot-d1c569251281f56eadd25f1c81d82da1b3c242d9.zip
PRD: fixed no gard when PLL and CS at same time
Change-Id: If5f6f2e1d29e3223c26c525f5ee9b54904e65891 CQ: SW412820 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/51502 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Reviewed-by: Caleb N. Palmer <cnpalmer@us.ibm.com> Reviewed-by: Brian J. Stegmiller <bjs@us.ibm.com> Reviewed-by: Benjamin J. Weisenbeck <bweisenb@us.ibm.com> Reviewed-by: Zane C. Shelley <zshelle@us.ibm.com> Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/51861 Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Diffstat (limited to 'src')
-rw-r--r--src/usr/diag/prdf/common/plat/p9/prdfP9PllDomain.C22
1 files changed, 21 insertions, 1 deletions
diff --git a/src/usr/diag/prdf/common/plat/p9/prdfP9PllDomain.C b/src/usr/diag/prdf/common/plat/p9/prdfP9PllDomain.C
index 2d0dd36f8..b99e77bc8 100644
--- a/src/usr/diag/prdf/common/plat/p9/prdfP9PllDomain.C
+++ b/src/usr/diag/prdf/common/plat/p9/prdfP9PllDomain.C
@@ -5,7 +5,7 @@
/* */
/* OpenPOWER HostBoot Project */
/* */
-/* Contributors Listed Below - COPYRIGHT 2016,2017 */
+/* Contributors Listed Below - COPYRIGHT 2016,2018 */
/* [+] International Business Machines Corp. */
/* */
/* */
@@ -197,6 +197,26 @@ int32_t PllDomain::Analyze(STEP_CODE_DATA_STRUCT & serviceData,
}
}
+ // TODO: RTC 184513 - It is possible to have a PLL unlock, a UE RE, and an
+ // SUE CS. Isolation should be to the PLL error and then the
+ // additional FFDC should show there was an SUE CS were the root is
+ // the UE RE. However, PRD does not know how to handle three
+ // attentions at the same time. For now this will remain a limitation
+ // due to time contraits, but there is a proposal in RTC 184513 that
+ // will be solved later. In the meantime, there is a hole in our
+ // analysis that needs to be fixed. If the is a SUE CS and no UE RE,
+ // PRD assumes the UE RE was already predictively called out in a
+ // previous error log. Therefore, nothing will be garded in this error
+ // log. In the example stated above, the current PRD code will not see
+ // the UE RE because of the higher priority PLL unlock. So even though
+ // there is a UE RE present, nothing gets garded. To circumvent this,
+ // we will set the UERE flag here even though the PLL error is not the
+ // true SUE source.
+ if ( CHECK_STOP == serviceData.service_data->getPrimaryAttnType() )
+ {
+ serviceData.service_data->SetUERE();
+ }
+
// TODO: RTC 155673 - use attributes to callout active clock sources
// For Nimbus sys ref and mf ref clock source is the same
OpenPOWER on IntegriCloud