Add support for NVDIMM secure erase verify
Add nvdimm operations to interface Add wrapper for factory default function Add secure erase verify start function Add secure erase verify status function Change-Id: I84774e679593e7df1907c1a442c831b2f4df88d9 CQ:SW475562 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/84301 Reviewed-by: Matt Derksen <mderkse1@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Roland Veloz <rveloz@us.ibm.com> Reviewed-by: Daniel M Crowell <dcrowell@us.ibm.com>
Diffstat (limited to 'src/usr/isteps/nvdimm/ReadMe.md')
-rw-r--r--src/usr/isteps/nvdimm/ReadMe.md54
1 files changed, 54 insertions, 0 deletions
diff --git a/src/usr/isteps/nvdimm/ReadMe.md b/src/usr/isteps/nvdimm/ReadMe.md
index 2b4fd4901..1f98438b2 100644
--- a/src/usr/isteps/nvdimm/ReadMe.md
+++ b/src/usr/isteps/nvdimm/ReadMe.md
@@ -222,3 +222,57 @@ in the JEDEC document JESD245B
12. Disable firmware update mode
13. Switch from slot0 to slot1 which contains the new image code
14. Validate running new code level
+
+# NVDIMM Secure Erase Verify Flow
+DS8K lpar -> HBRT NVDIMM operation = factory_default + secure_erase_verify_start
+ HBRT executes factory_default and steps 1) and 2)
+DS8K lpar -> HBRT NVDIMM operation = secure_erase_verify_complete
+ HBRT executes step 3)
+ If secure erase verify has not completed, return status with verify_complete bit = 0
+ DS8K lpar is responsible for monitoring elapsed time (2/4 hours) and restart process (step 6)
+ If secure erase verify has completed
+ HBRT executes steps 4) and 5), generating error logs for any non-zero register values
+ Return status with verify_complete bit = 1
+
+## Procedure Flow for NVDIMM Secure Erase Verify
+ *Note: Secure Erase Verify should only be run after a Factory Default operation.
+ Secure Erase Verify is intended to verify whether all NAND blocks have been erased.
+ *Note: Full breakout of all Page 5 Secure Erase Verify registers can be found in
+ SMART document "JEDEC NVDIMM Vendor Page 2 Extensions".
+ 1) Set Page 5 Register 0x1B to value "0x00"
+ // this clears the status register
+ 2) Set Page 5 Register 0x1A to value "0xC0"
+ // this kicks off the erase verify operation
+ 3) Wait for Page 5 Register 0x1A Bit 7 to be reset to value "0"
+ // i.e., the overall register value should be "0x40";
+ this means that erase verify has completed
+ a. If Page 5 Register 0x1A Bit 7 has not reset to value "0"
+ after 2 hours (16GB NVDIMM) or after 4 hours (32GB NVDIMM),
+ report a timeout error and skip to step (6)
+ 4) Read Page 5 Register 0x1B; value should be "0x00"
+ // this is the erase verify status register
+ a. If Page 5 Register 0x1B value is not "0x00",
+ report any/all errors as outlined in the table at the end of this document,
+ then skip to step (6)
+ 5) Read Page 5 Registers 0x1D (MSB) and 0x1C (LSB);
+ combined the two registers should have a value of "0x0000"
+ // this is the number of chunks failing Secure Erase Verify
+ a. If the combined value of the two registers is not "0x0000",
+ report a threshold exceeded error along with the combined value of the two registers,
+ then skip to step (6)
+ 6) If any errors have been reported in steps (3), (4), or (5),
+ retry the secure erase verify operation starting again from step (1)
+ a. If the secure erase verify operation fails even after retrying,
+ report that secure erase verify operation has failed
+ 7) If no errors have been reported, report that secure erase verify operation
+ has been completed successfully
+ *Addendum: Breakout of Page 5 Register 0x1B Erase Verify Status bit values referenced in step (4) above.
+ All these bits should return as "0". Any bits returning as "1" should be reported with the error name below.
+ Bits 7:6 - Reserved
+ Bit 5 - BAD BLOCK
+ Bit 4 - OTHER
+ Bit 3 - ENCRYPTION LOCKED
+ Bit 2 - INVALID PARAMETER
+ Bit 1 - INTERRUPTED
+ Bit 0 - NAND ERROR
+