authorJoachim Fenkes <fenkes@de.ibm.com>2019-02-22 15:47:44 +0100
committerDaniel M. Crowell <dcrowell@us.ibm.com>2019-04-08 09:21:12 -0500
commit96195e47b5036a027dfa87c79cdae717d0c6cc2b (patch)
tree1d757a71920d4bc840e6e2ed9ddbfee36787827b /src/usr/isteps/istep14/call_proc_exit_cache_contained.C
parent63a8b58f12b7127eafebd3cd5a716ecfe3d924d6 (diff)
downloadtalos-hostboot-96195e47b5036a027dfa87c79cdae717d0c6cc2b.tar.gz
talos-hostboot-96195e47b5036a027dfa87c79cdae717d0c6cc2b.zip
Fix for workaround for HW480181
The workaround works fine when Cronus only sets up a single TOD topology, but once _actual_ firmware on an _actual_ system sets up a primary and backup topology, the simpleton fix wipes out part of the primary config when the backup config is set up. Fixed by only updating the partial register and only while the primary topology is being set up. Also fix MPIPL setup where a copy-paste error cause an invalid value in the master path control register. Change-Id: Ief4757cd1d082f18e625142f3e3246dfdc5771a2 Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/72337 Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: HWSV CI <hwsv-ci+hostboot@us.ibm.com> Tested-by: Hostboot CI <hostboot-ci+hostboot@us.ibm.com> Reviewed-by: Joseph J. McGill <jmcgill@us.ibm.com> Reviewed-by: Manish K. Chowdhary <manichow@in.ibm.com> Reviewed-by: Jennifer A. Stofer <stofer@us.ibm.com> Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/72350 Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
Diffstat (limited to 'src/usr/isteps/istep14/call_proc_exit_cache_contained.C')
0 files changed, 0 insertions, 0 deletions
OpenPOWER on IntegriCloud