diff options
author | Brian Bakke <bbakke@us.ibm.com> | 2018-05-22 11:30:26 -0500 |
---|---|---|
committer | Daniel M. Crowell <dcrowell@us.ibm.com> | 2018-06-07 13:37:46 -0400 |
commit | e364f91be1727019dd594c57d496e5ce43e8f5f0 (patch) | |
tree | 3515d4777d5ca4705fc232b02110d6c480151eff /src/lib/cxxtest_data.C | |
parent | 0c6d58230e615000dee1a1940bf4bc84ad5c1798 (diff) | |
download | talos-hostboot-e364f91be1727019dd594c57d496e5ce43e8f5f0.tar.gz talos-hostboot-e364f91be1727019dd594c57d496e5ce43e8f5f0.zip |
Fixes to node IPC messaging to handle non-zero base addresses
Current code has each Node calculate each Remote Node's IPC area
remote address by performing a fixed format calculation.
This change has each Node calculating its IPC area Remote address
and posting this value to a local SCOM register. A Node reads
a Remote Node's SCOM register to acquire the Remote IPC area
address.
Change-Id: I25260ce180e0d07e5e81990d4c1f99e249912491
RTC:191463
Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/59177
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Prachi Gupta <pragupta@us.ibm.com>
Reviewed-by: Daniel M. Crowell <dcrowell@us.ibm.com>
Diffstat (limited to 'src/lib/cxxtest_data.C')
0 files changed, 0 insertions, 0 deletions