summaryrefslogtreecommitdiffstats
path: root/src/include/usr/fapi2/attribute_service.H
diff options
context:
space:
mode:
authorDean Sanner <dsanner@us.ibm.com>2017-12-20 14:29:14 -0600
committerWilliam G. Hoffa <wghoffa@us.ibm.com>2018-01-10 10:54:24 -0500
commit6407898fc569eb63527c6960dbb0ed9e1ebb0212 (patch)
tree397668e5c9a60ee20b624123392fe83569bda71e /src/include/usr/fapi2/attribute_service.H
parent4592e5a256c41eece80e55907535a76d07b36572 (diff)
downloadtalos-hostboot-6407898fc569eb63527c6960dbb0ed9e1ebb0212.tar.gz
talos-hostboot-6407898fc569eb63527c6960dbb0ed9e1ebb0212.zip
Connect CDIMM power/slope ATTR with VPD accessor function
Change-Id: I7bd048fb17d8041ae97054f6aa30e9dd94c6eaf5 Reviewed-on: http://ralgit01.raleigh.ibm.com/gerrit1/51212 Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com> Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com> Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com> Reviewed-by: Prachi Gupta <pragupta@us.ibm.com> Reviewed-by: Martin Gloff <mgloff@us.ibm.com> Reviewed-by: William G. Hoffa <wghoffa@us.ibm.com>
Diffstat (limited to 'src/include/usr/fapi2/attribute_service.H')
-rw-r--r--src/include/usr/fapi2/attribute_service.H95
1 files changed, 94 insertions, 1 deletions
diff --git a/src/include/usr/fapi2/attribute_service.H b/src/include/usr/fapi2/attribute_service.H
index dfdd23803..eb1a1e9ed 100644
--- a/src/include/usr/fapi2/attribute_service.H
+++ b/src/include/usr/fapi2/attribute_service.H
@@ -5,7 +5,7 @@
/* */
/* OpenPOWER HostBoot Project */
/* */
-/* Contributors Listed Below - COPYRIGHT 2015,2017 */
+/* Contributors Listed Below - COPYRIGHT 2015,2018 */
/* [+] International Business Machines Corp. */
/* */
/* */
@@ -438,6 +438,18 @@ ReturnCode getPllBucket(const Target<TARGET_TYPE_ALL>& i_fapiTarget,
uint8_t &o_bucket_val,
const uint8_t i_index);
+/// @brief This function is called by the FAPI_ATTR_GET macro when getting
+// the CEN_CDIMM_VPD_* attributes. It should not be called directly.
+//
+// @param[in] i_fapiTarget The target for the attribute operation.
+// @param[in] i_attr Which ATTR extracting from VPD
+// @param[out] o_val The retrieved attribute value.
+// @return ReturnCode Zero on success, else platform specified error.
+ReturnCode platGetMBvpdSlopeInterceptData(
+ const Target<TARGET_TYPE_ALL>& i_fapiTarget,
+ const uint32_t i_attr,
+ uint32_t& o_val);
+
// -----------------------------------------------------------------------------
// End TODO: End to be supported functions
// -----------------------------------------------------------------------------
@@ -1455,5 +1467,86 @@ fapiToTargeting::ID, sizeof(VAL), &(VAL))
fapi2::platAttrSvc::\
platGetMBvpdAttr<fapi2::ATTR_CEN_VPD_MT_DATA_CONTROL_BYTE_Type>(ID, TARGET, VAL)
+//----------------------------------------------------------------------------
+// MACRO to route ATTR_CEN_CDIMM_VPD_MASTER_POWER_INTERCEPT access to the correct
+// HB function
+//----------------------------------------------------------------------------
+#define ATTR_CEN_CDIMM_VPD_MASTER_POWER_INTERCEPT_GETMACRO(ID, TARGET, VAL) \
+ AttrOverrideSync::getAttrOverrideFunc(ID, TARGET, &VAL)\
+ ? fapi2::ReturnCode() : \
+ fapi2::platAttrSvc::\
+ platGetMBvpdSlopeInterceptData(TARGET, ID, VAL)
+
+//----------------------------------------------------------------------------
+// MACRO to route ATTR_CEN_CDIMM_VPD_MASTER_POWER_SLOPE access to the correct
+// HB function
+//----------------------------------------------------------------------------
+#define ATTR_CEN_CDIMM_VPD_MASTER_POWER_SLOPE_GETMACRO(ID, TARGET, VAL) \
+ AttrOverrideSync::getAttrOverrideFunc(ID, TARGET, &VAL)\
+ ? fapi2::ReturnCode() : \
+ fapi2::platAttrSvc::\
+ platGetMBvpdSlopeInterceptData(TARGET, ID, VAL)
+
+//----------------------------------------------------------------------------
+// MACRO to route ATTR_CEN_CDIMM_VPD_MASTER_TOTAL_POWER_INTERCEPT access to
+// the correct HB function
+//----------------------------------------------------------------------------
+#define ATTR_CEN_CDIMM_VPD_MASTER_TOTAL_POWER_INTERCEPT_GETMACRO(ID, TARGET, VAL) \
+ AttrOverrideSync::getAttrOverrideFunc(ID, TARGET, &VAL)\
+ ? fapi2::ReturnCode() : \
+ fapi2::platAttrSvc::\
+ platGetMBvpdSlopeInterceptData(TARGET, ID, VAL)
+
+//----------------------------------------------------------------------------
+// MACRO to route ATTR_CEN_CDIMM_VPD_MASTER_TOTAL_POWER_SLOPE access to
+// the correct HB function
+//----------------------------------------------------------------------------
+#define ATTR_CEN_CDIMM_VPD_MASTER_TOTAL_POWER_SLOPE_GETMACRO(ID, TARGET, VAL) \
+ AttrOverrideSync::getAttrOverrideFunc(ID, TARGET, &VAL)\
+ ? fapi2::ReturnCode() : \
+ fapi2::platAttrSvc::\
+ platGetMBvpdSlopeInterceptData(TARGET, ID, VAL)
+
+//----------------------------------------------------------------------------
+// MACRO to route ATTR_CEN_CDIMM_VPD_SUPPLIER_POWER_INTERCEPT access to the correct
+// HB function
+//----------------------------------------------------------------------------
+#define ATTR_CEN_CDIMM_VPD_SUPPLIER_POWER_INTERCEPT_GETMACRO(ID, TARGET, VAL) \
+ AttrOverrideSync::getAttrOverrideFunc(ID, TARGET, &VAL)\
+ ? fapi2::ReturnCode() : \
+ fapi2::platAttrSvc::\
+ platGetMBvpdSlopeInterceptData(TARGET, ID, VAL)
+
+//----------------------------------------------------------------------------
+// MACRO to route ATTR_CEN_CDIMM_VPD_SUPPLIER_POWER_SLOPE access to the correct
+// HB function
+//----------------------------------------------------------------------------
+#define ATTR_CEN_CDIMM_VPD_SUPPLIER_POWER_SLOPE_GETMACRO(ID, TARGET, VAL) \
+ AttrOverrideSync::getAttrOverrideFunc(ID, TARGET, &VAL)\
+ ? fapi2::ReturnCode() : \
+ fapi2::platAttrSvc::\
+ platGetMBvpdSlopeInterceptData(TARGET, ID, VAL)
+
+//----------------------------------------------------------------------------
+// MACRO to route ATTR_CEN_CDIMM_VPD_SUPPLIER_TOTAL_POWER_INTERCEPT access to
+// the correct HB function
+//----------------------------------------------------------------------------
+#define ATTR_CEN_CDIMM_VPD_SUPPLIER_TOTAL_POWER_INTERCEPT_GETMACRO(ID, TARGET, VAL) \
+ AttrOverrideSync::getAttrOverrideFunc(ID, TARGET, &VAL)\
+ ? fapi2::ReturnCode() : \
+ fapi2::platAttrSvc::\
+ platGetMBvpdSlopeInterceptData(TARGET, ID, VAL)
+
+//----------------------------------------------------------------------------
+// MACRO to route ATTR_CEN_CDIMM_VPD_SUPPLIER_TOTAL_POWER_SLOPE access to
+// the correct HB function
+//----------------------------------------------------------------------------
+#define ATTR_CEN_CDIMM_VPD_SUPPLIER_TOTAL_POWER_SLOPE_GETMACRO(ID, TARGET, VAL) \
+ AttrOverrideSync::getAttrOverrideFunc(ID, TARGET, &VAL)\
+ ? fapi2::ReturnCode() : \
+ fapi2::platAttrSvc::\
+ platGetMBvpdSlopeInterceptData(TARGET, ID, VAL)
+
+
#endif // ATTRIBUTESERVICE_H_