add tuning enable variable
Add a variable that when set, enables tuning logging. This variable is
set to false.
Tuning can be enabled via "-t" "--tuning" on the command line.
With a parameter is the path where to write the logging information.
Change-Id: I6eb8035d56cc3301face21e9375c02fc9fcc5b31
Signed-off-by: Patrick Venture <venture@google.com>
Diffstat (limited to 'pid')
| -rw-r--r-- | pid/fancontroller.cpp | 14 | ||||
| -rw-r--r-- | pid/pidthread.cpp | 18 | ||||
| -rw-r--r-- | pid/tuning.cpp | 20 | ||||
| -rw-r--r-- | pid/tuning.hpp | 9 | ||||
| -rw-r--r-- | pid/zone.cpp | 77 | ||||
| -rw-r--r-- | pid/zone.hpp | 12 |
6 files changed, 93 insertions, 57 deletions
diff --git a/pid/fancontroller.cpp b/pid/fancontroller.cpp index 4a61def..4c1b56b 100644 --- a/pid/fancontroller.cpp +++ b/pid/fancontroller.cpp @@ -16,6 +16,7 @@ #include "fancontroller.hpp" +#include "tuning.hpp" #include "util.hpp" #include "zone.hpp" @@ -115,16 +116,17 @@ void FanController::outputProc(double value) double percent = value; /* If doing tuning logging, don't go into failsafe mode. */ -#ifndef __TUNING_LOGGING__ - if (_owner->getFailSafeMode()) + if (!tuningLoggingEnabled) { - /* In case it's being set to 100% */ - if (percent < _owner->getFailSafePercent()) + if (_owner->getFailSafeMode()) { - percent = _owner->getFailSafePercent(); + /* In case it's being set to 100% */ + if (percent < _owner->getFailSafePercent()) + { + percent = _owner->getFailSafePercent(); + } } } -#endif // value and kFanFailSafeDutyCycle are 10 for 10% so let's fix that. percent /= 100; diff --git a/pid/pidthread.cpp b/pid/pidthread.cpp index 08fb513..f8d7fd9 100644 --- a/pid/pidthread.cpp +++ b/pid/pidthread.cpp @@ -17,6 +17,7 @@ #include "pidthread.hpp" #include "pid/pidcontroller.hpp" +#include "pid/tuning.hpp" #include "sensors/sensor.hpp" #include <chrono> @@ -63,9 +64,11 @@ void pidControlThread(PIDZone* zone) * TODO(venture): If the fan value is 0 should that loop just be skipped? * Right now, a 0 value is ignored in FanController::inputProc() */ -#ifdef __TUNING_LOGGING__ - zone->initializeLog(); -#endif + if (tuningLoggingEnabled) + { + zone->initializeLog(); + } + zone->initializeCache(); processThermals(zone); @@ -93,10 +96,11 @@ void pidControlThread(PIDZone* zone) // Run the fan PIDs every iteration. zone->processFans(); -#ifdef __TUNING_LOGGING__ - zone->getLogHandle() << "," << zone->getFailSafeMode(); - zone->getLogHandle() << std::endl; -#endif + if (tuningLoggingEnabled) + { + zone->getLogHandle() << "," << zone->getFailSafeMode(); + zone->getLogHandle() << std::endl; + } ms100cnt += 1; } diff --git a/pid/tuning.cpp b/pid/tuning.cpp new file mode 100644 index 0000000..c3f21ed --- /dev/null +++ b/pid/tuning.cpp @@ -0,0 +1,20 @@ +/** + * Copyright 2019 Google Inc. + * + * Licensed under the Apache License, Version 2.0 (the "License"); + * you may not use this file except in compliance with the License. + * You may obtain a copy of the License at + * + * http://www.apache.org/licenses/LICENSE-2.0 + * + * Unless required by applicable law or agreed to in writing, software + * distributed under the License is distributed on an "AS IS" BASIS, + * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. + * See the License for the specific language governing permissions and + * limitations under the License. + */ + +#include <string> + +bool tuningLoggingEnabled = false; +std::string tuningLoggingPath; diff --git a/pid/tuning.hpp b/pid/tuning.hpp new file mode 100644 index 0000000..511c797 --- /dev/null +++ b/pid/tuning.hpp @@ -0,0 +1,9 @@ +#pragma once + +#include <string> + +/** Boolean variable controlling whether tuning logging output is enabled + * during this run. + */ +extern bool tuningLoggingEnabled; +extern std::string tuningLoggingPath; diff --git a/pid/zone.cpp b/pid/zone.cpp index 7433d30..928aef5 100644 --- a/pid/zone.cpp +++ b/pid/zone.cpp @@ -23,6 +23,7 @@ #include "pid/fancontroller.hpp" #include "pid/stepwisecontroller.hpp" #include "pid/thermalcontroller.hpp" +#include "pid/tuning.hpp" #include <algorithm> #include <chrono> @@ -138,38 +139,38 @@ void PIDZone::determineMaxRPMRequest(void) */ max = std::max(getMinThermalRPMSetpoint(), max); -#ifdef __TUNING_LOGGING__ - /* - * We received no setpoints from thermal sensors. - * This is a case experienced during tuning where they only specify - * fan sensors and one large fan PID for all the fans. - */ - static constexpr auto setpointpath = "/etc/thermal.d/setpoint"; - try + if (tuningLoggingEnabled) { - std::ifstream ifs; - ifs.open(setpointpath); - if (ifs.good()) + /* + * We received no setpoints from thermal sensors. + * This is a case experienced during tuning where they only specify + * fan sensors and one large fan PID for all the fans. + */ + static constexpr auto setpointpath = "/etc/thermal.d/setpoint"; + try { - int value; - ifs >> value; + std::ifstream ifs; + ifs.open(setpointpath); + if (ifs.good()) + { + int value; + ifs >> value; - /* expecting RPM setpoint, not pwm% */ - max = static_cast<double>(value); + /* expecting RPM setpoint, not pwm% */ + max = static_cast<double>(value); + } + } + catch (const std::exception& e) + { + /* This exception is uninteresting. */ + std::cerr << "Unable to read from '" << setpointpath << "'\n"; } } - catch (const std::exception& e) - { - /* This exception is uninteresting. */ - std::cerr << "Unable to read from '" << setpointpath << "'\n"; - } -#endif _maximumRPMSetPt = max; return; } -#ifdef __TUNING_LOGGING__ void PIDZone::initializeLog(void) { /* Print header for log file: @@ -196,7 +197,6 @@ std::ofstream& PIDZone::getLogHandle(void) { return _log; } -#endif /* * TODO(venture) This is effectively updating the cache and should check if the @@ -217,13 +217,14 @@ void PIDZone::updateFanTelemetry(void) * is disabled? I think it's a waste to try and log things even if the * data is just being dropped though. */ -#ifdef __TUNING_LOGGING__ - tstamp now = std::chrono::high_resolution_clock::now(); - _log << std::chrono::duration_cast<std::chrono::milliseconds>( - now.time_since_epoch()) - .count(); - _log << "," << _maximumRPMSetPt; -#endif + if (tuningLoggingEnabled) + { + tstamp now = std::chrono::high_resolution_clock::now(); + _log << std::chrono::duration_cast<std::chrono::milliseconds>( + now.time_since_epoch()) + .count(); + _log << "," << _maximumRPMSetPt; + } for (const auto& f : _fanInputs) { @@ -236,17 +237,19 @@ void PIDZone::updateFanTelemetry(void) * However, these are the fans, so if I'm not getting updated values * for them... what should I do? */ -#ifdef __TUNING_LOGGING__ - _log << "," << r.value; -#endif + if (tuningLoggingEnabled) + { + _log << "," << r.value; + } } -#ifdef __TUNING_LOGGING__ - for (const auto& t : _thermalInputs) + if (tuningLoggingEnabled) { - _log << "," << _cachedValuesByName[t]; + for (const auto& t : _thermalInputs) + { + _log << "," << _cachedValuesByName[t]; + } } -#endif return; } diff --git a/pid/zone.hpp b/pid/zone.hpp index 94082e9..a458011 100644 --- a/pid/zone.hpp +++ b/pid/zone.hpp @@ -5,6 +5,7 @@ #include "pidcontroller.hpp" #include "sensors/manager.hpp" #include "sensors/sensor.hpp" +#include "tuning.hpp" #include <fstream> #include <map> @@ -51,9 +52,10 @@ class PIDZone : public ZoneInterface, public ModeObject _minThermalOutputSetPt(minThermalOutput), _failSafePercent(failSafePercent), _mgr(mgr) { -#ifdef __TUNING_LOGGING__ - _log.open("/tmp/swampd.log"); -#endif + if (tuningLoggingEnabled && !tuningLoggingPath.empty()) + { + _log.open(tuningLoggingPath); + } } double getMaxRPMRequest(void) const override; @@ -87,10 +89,8 @@ class PIDZone : public ZoneInterface, public ModeObject void addFanInput(const std::string& fan); void addThermalInput(const std::string& therm); -#ifdef __TUNING_LOGGING__ void initializeLog(void); std::ofstream& getLogHandle(void); -#endif /* Method for setting the manual mode over dbus */ bool manual(bool value) override; @@ -98,9 +98,7 @@ class PIDZone : public ZoneInterface, public ModeObject bool failSafe() const override; private: -#ifdef __TUNING_LOGGING__ std::ofstream _log; -#endif const int64_t _zoneId; double _maximumRPMSetPt = 0; |