Add performance improvement to LED group assertions
Consider the below scenario: 1) User turns on Identify_Fan_1, which results in Fan_1's LED to blink 2) Fan_1 is faulted resulting in Fan_1, EncFaultFront and EncFaultBack to be asserted. 3) User turuns off Identify_Fan_1. This should result in Fan_1 going back to SolidOn state since the Fan_1 is still faulted. Current implementation handles #3 by first turning off Fan_1 LED and then turning it back on. So this was adding extra dbus calls to the actual LED manager and also this would mean that Group manager would know the underlying LED implementation. With this patch, Group Manager tells the physical manager to move to SolidOn state directly from Blink and physical LED manager now has the job of doing the actual turn off followed by turn on and thus hiding the implementation locally. Fixes openbmc/phosphor-led-manager#3 Change-Id: Ic961095d01e59ba39a841ce8b74bbcde8ddec1df Signed-off-by: Vishwanatha Subbanna <vishwa@linux.vnet.ibm.com>