Rework of host-management.md
Reworked the host-management.md document. Updated example
calls from the old /org/openbmc, to /xyz/openbmc_project.
Changed //bmc/ to //${bmc}/. Updated Event logs, Host State,
Boot Options, Sensors, and Inventory sections to be correct.
Change-Id: Ia914b13f5217c19b37d1377092e68c66ac9b74c7
Signed-off-by: Gunnar Mills <gmills@us.ibm.com>
| -rw-r--r-- | host-management.md | 194 |
1 files changed, 123 insertions, 71 deletions
diff --git a/host-management.md b/host-management.md index 10cb4bd..4567717 100644 --- a/host-management.md +++ b/host-management.md @@ -7,37 +7,37 @@ structure, accessible over REST. Inventory --------- -The system inventory structure is under the `/org/openbmc/inventory` hierarchy. +The system inventory structure is under the `/xyz/openbmc_project/inventory` hierarchy. In OpenBMC the inventory is represented as a path which is hierarchical to the physical system topology. Items in the inventory are referred to as inventory -items and are not necessarily FRUs. If the system contains one chassis, a -motherboard, and a CPU on the motherboard, then the path to that inventory item -would be: +items and are not necessarily FRUs (field-replaceable units). If the system +contains one chassis, a motherboard, and a CPU on the motherboard, then the +path to that inventory item would be: inventory/system/chassis0/motherboard0/cpu0 -The properties associated with an inventory item are specific to that item with -the addition of these common properties: +The properties associated with an inventory item are specific to that item. +Some common properties are: - * `version`: a code version associated with this item - * `fault`: indicates whether this item has reported an error condition (True/False) - * `present`: indicates whether this item is present in the system (True/False) + * `Version`: A code version associated with this item. + * `Present`: Indicates whether this item is present in the system (True/False). + * `Functional`: Indicates whether this item is functioning in the system (True/False). The usual `list` and `enumerate` REST queries allow the system inventory structure to be accessed. For example, to enumerate all inventory items and their properties: - curl -b cjar -k https://bmc/org/openbmc/inventory/enumerate + curl -b cjar -k https://${bmc}/xyz/openbmc_project/inventory/enumerate To list the properties of one item: - curl -b cjar -k https://bmc/org/openbmc/inventory/system/chassis/motherboard + curl -b cjar -k https://${bmc}/xyz/openbmc_project/inventory/system/chassis/motherboard Sensors ------- -The system inventory structure is under the `/org/openbmc/sensors` hierarchy. +The system sensor structure is under the `/xyz/openbmc_project/sensors` hierarchy. This interface allows monitoring of system attributes like temperature or altitude, and are represented similar to the inventory, by object paths under @@ -48,53 +48,82 @@ topology of the system. For example, all temperature sensors are under `sensors/temperature`. CPU temperature sensors would be `sensors/temperature/cpu[n]`. -These are the common properties associated all sensors: +These are some common properties: - * `value`: current value of sensor - * `units`: units of value - * `warning_upper` & `warning_lower`: upper & lower threshold for a warning error - * `critical_upper` & `critical_lower`: upper & lower threshold for a critical error - * `threshold_state`: current threshold state (normal, warning, critical) - * `worst_threshold_state`: highest threshold state seen for all time. There is - a REST call to reset this state to normal. + * `Value`: Current value of the sensor + * `Unit`: Unit of the value and "Critical" and "Warning" values + * `Scale`: The scale of the value and "Critical" and "Warning" values + * `CriticalHigh` & `CriticalLow`: Sensor device upper/lower critical threshold bound + * `CriticalAlarmHigh` & `CriticalAlarmLow`: True if the sensor has exceeded the +critical threshold bound + * `WarningHigh` & `WarningLow`: Sensor device upper/lower warning threshold bound + * `WarningAlarmHigh` & `WarningAlarmLow`: True if the sensor has exceeded the +warning threshold bound + +A temperature sensor might look like: + + curl -b cjar -k https://${bmc}/xyz/openbmc_project/sensors/temperature/pcie + { + "data": { + "CriticalAlarmHigh": 0, + "CriticalAlarmLow": 0, + "CriticalHigh": 70000, + "CriticalLow": 0, + "Scale": -3, + "Unit": "xyz.openbmc_project.Sensor.Value.Unit.DegreesC", + "Value": 28187, + "WarningAlarmHigh": 0, + "WarningAlarmLow": 0, + "WarningHigh": 60000, + "WarningLow": 0 + }, + "message": "200 OK", + "status": "ok" + } + +Note the value of this sensor is 28.187C (28187 * 10^-3). Unlike IPMI, there are no "functional" sensors in OpenBMC; functional states are represented in the inventory. To enumerate all sensors in the system: - curl -c cjar -k https://bmc/org/openbmc/sensors/enumerate + curl -b cjar -k https://${bmc}/xyz/openbmc_project/sensors/enumerate List properties of one inventory item: - curl -c cjar -k https://bmc/org/openbmc/sensors/temperature/ambient + curl -b cjar -k https://${bmc}/xyz/openbmc_project/sensors/temperature/ambient Event Logs ---------- -The event log structure is under the `/org/openbmc/records/events` hierarchy. +The event log structure is under the `/xyz/openbmc_project/logging/entry` hierarchy. Each event is a separate object under this structure, referenced by number. -BMC and host firmware on POWER-based servers can report logs to the BMC. -Typically, these logs are reported in cases where host firmware cannot start the +BMC and host firmware on POWER-based servers can report event logs to the BMC. +Typically, these event logs are reported in cases where host firmware cannot start the OS, or cannot reliably log to the OS. -The properties associated with an error log are as follows: +The properties associated with an event log are as follows: - * `Association`: a uri to the failing inventory part - * `Message`: An English text string indicating the failure - * `Reported By`: Firmware region that created the log ('Host', 'BMC') - * `Severity`: level of problem (Info, Predictive Error, etc) - * `Development Data`: Data dump for use by Development to analyze the failure + * `Message`: The type of event log (e.g. "xyz.openbmc_project.Inventory.Error.NotPresent"). + * `Resolved` : Indicates whether the event has been resolved. + * `Severity`: The level of problem ("Info", "Error", etc.). + * `Timestamp`: The date of the event log in epoch time. + * `associations`: A URI to the failing inventory part. -To list all reported events: +To list all reported event logs: - $ curl -b cjar -k https://bmc/org/openbmc/records/events/ + $ curl -b cjar -k https://${bmc}/xyz/openbmc_project/logging/entry/ { "data": [ - "/org/openbmc/records/events/1", - "/org/openbmc/records/events/2", - "/org/openbmc/records/events/3", + "/xyz/openbmc_project/logging/entry/3", + "/xyz/openbmc_project/logging/entry/2", + "/xyz/openbmc_project/logging/entry/1", + "/xyz/openbmc_project/logging/entry/7", + "/xyz/openbmc_project/logging/entry/6", + "/xyz/openbmc_project/logging/entry/5", + "/xyz/openbmc_project/logging/entry/4" ], "message": "200 OK", "status": "ok" @@ -102,65 +131,88 @@ To list all reported events: To read a specific event log: - $ curl -b cjar -k https://bmc/org/openbmc/records/events/1 + $ curl -b cjar -k https://${bmc}/xyz/openbmc_project/logging/entry/1 { "data": { - "association": "/org/openbmc/inventory/system/systemevent", - "debug_data": [ ... ], - "message": "A systemevent has experienced a unrecoverable error", - "reported_by": "Host", - "severity": "unrecoverable error", - "time": "2016:05:04 01:43:57" + "AdditionalData": [ + "CALLOUT_INVENTORY_PATH=/xyz/openbmc_project/inventory/system/chassis/powersupply0", + "_PID=1136" + ], + "Id": 1, + "Message": "xyz.openbmc_project.Inventory.Error.NotPresent", + "Resolved": 0, + "Severity": "xyz.openbmc_project.Logging.Entry.Level.Error", + "Timestamp": 1512154612660, + "associations": [ + [ + "callout", + "fault", + "/xyz/openbmc_project/inventory/system/chassis/powersupply0" + ] + ] }, "message": "200 OK", "status": "ok" } -To delete an event log (log 1 in his example), call the `delete` method on the event: +To delete an event log (log 1 in this example), call the `delete` method on the event: curl -b cjar -k -H "Content-Type: application/json" -X POST \ -d '{"data" : []}' \ - https://bmc/org/openbmc/records/events/1/action/delete + https://${bmc}/xyz/openbmc_project/logging/entry/1/action/Delete -To clear all logs, call the top-level `clear` method: +To clear all event logs, call the top-level `deleteAll` method: curl -b cjar -k -H "Content-Type: application/json" -X POST \ -d '{"data" : []}' \ - https://bmc/org/openbmc/records/events/action/clear + https://${bmc}/xyz/openbmc_project/logging/action/deleteAll -BIOS boot options +Host Boot Options ----------------- -With OpenBMC, the BIOS boot options are stored as D-Bus properties under the -`settings/host0` path, in the `boot_flags` property. Their format adheres to the -Boot Options Parameters table specified in the IPMI Specification Document, -section 28.13. +With OpenBMC, the Host boot options are stored as D-Bus properties under the +`control/host0/boot` path. Properties include `BootMode` and `BootSource`. -Each boot parameter is represented by an individual property, and their hex -value is displayed in a string format. For example, a boot flags parameter value -of `0x8014000000` would be stored as a `8014000000` string in the -`settings/host0/boot_flags` property. -Host power control +Host State Control ------------------ -The host can be controlled through the `chassis` object. It implements a number -of actions including powerOn and powerOff. These correspond to the IPMI -`chassis power on` and `chassis power off` commands. +The host can be controlled through the `host` object. The object implements a number +of actions including power on and power off. These correspond to the IPMI +`power on` and `power off` commands. + +Assuming you have logged in, the following will power on the host: + +``` +curl -c cjar -b cjar -k -H "Content-Type: application/json" -X PUT \ + -d '{"data": "xyz.openbmc_project.State.Host.Transition.On"}' \ + https://${bmc}/xyz/openbmc_project/state/host0/attr/RequestedHostTransition +``` + +To power off the host: + +``` +curl -c cjar -b cjar -k -H "Content-Type: application/json" -X PUT \ + -d '{"data": "xyz.openbmc_project.State.Host.Transition.Off"}' \ + https://${bmc}/xyz/openbmc_project/state/host0/attr/RequestedHostTransition +``` + +To issue a hard power off (accomplished by powering off the chassis): + +``` +curl -c cjar -b cjar -k -H "Content-Type: application/json" -X PUT \ + -d '{"data": "xyz.openbmc_project.State.Chassis.Transition.Off"}' \ + https://${bmc}/xyz/openbmc_project/state/chassis0/attr/RequestedPowerTransition +``` -Assuming you have logged in, the following will issue a POST with an empty data -payload that powers the host on: +To reboot the host: ``` -curl -c cjar -b cjar -k -H "Content-Type: application/json" -X POST \ - -d '{"data": []}' https://bmc/org/openbmc/control/chassis0/action/powerOn +curl -c cjar -b cjar -k -H "Content-Type: application/json" -X PUT \ + -d '{"data": "xyz.openbmc_project.State.Host.Transition.Reboot"}' \ + https://${bmc}/xyz/openbmc_project/state/host0/attr/RequestedHostTransition ``` -Other actions available are: - * `setIdentify` / `clearIdentify` - * `powerOff` - * `softPowerOff` - * `reboot` - * `softReboot` - * `getPowerState` +More information about Host State Management can be found here: +https://github.com/openbmc/phosphor-dbus-interfaces/tree/master/xyz/openbmc_project/State |