1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
|
[
{
"PublicDescription": "This event counts the number of instructions retired from execution. For instructions that consist of multiple micro-ops, this event counts the retirement of the last micro-op of the instruction. Counting continues during hardware interrupts, traps, and inside interrupt handlers. \nNotes: INST_RETIRED.ANY is counted by a designated fixed counter, leaving the four (eight when Hyperthreading is disabled) programmable counters available for other events. INST_RETIRED.ANY_P is counted by a programmable counter and it is an architectural performance event. \nCounting: Faulting executions of GETSEC/VM entry/VM Exit/MWait will not count as retired instructions.",
"EventCode": "0x00",
"Counter": "Fixed counter 1",
"UMask": "0x1",
"EventName": "INST_RETIRED.ANY",
"SampleAfterValue": "2000003",
"BriefDescription": "Instructions retired from execution.",
"CounterHTOff": "Fixed counter 1"
},
{
"PublicDescription": "This event counts the number of core cycles while the thread is not in a halt state. The thread enters the halt state when it is running the HLT instruction. This event is a component in many key event ratios. The core frequency may change from time to time due to transitions associated with Enhanced Intel SpeedStep Technology or TM2. For this reason this event may have a changing ratio with regards to time. When the core frequency is constant, this event can approximate elapsed time while the core was not in the halt state. It is counted on a dedicated fixed counter, leaving the four (eight when Hyperthreading is disabled) programmable counters available for other events.",
"EventCode": "0x00",
"Counter": "Fixed counter 2",
"UMask": "0x2",
"EventName": "CPU_CLK_UNHALTED.THREAD",
"SampleAfterValue": "2000003",
"BriefDescription": "Core cycles when the thread is not in halt state",
"CounterHTOff": "Fixed counter 2"
},
{
"PublicDescription": "This event counts the number of reference cycles when the core is not in a halt state. The core enters the halt state when it is running the HLT instruction or the MWAIT instruction. This event is not affected by core frequency changes (for example, P states, TM2 transitions) but has the same incrementing frequency as the time stamp counter. This event can approximate elapsed time while the core was not in a halt state. This event has a constant ratio with the CPU_CLK_UNHALTED.REF_XCLK event. It is counted on a dedicated fixed counter, leaving the four (eight when Hyperthreading is disabled) programmable counters available for other events. Note: On all current platforms this event stops counting during 'throttling (TM)' states duty off periods the processor is 'halted'. The counter update is done at a lower clock rate then the core clock the overflow status bit for this counter may appear 'sticky'. After the counter has overflowed and software clears the overflow status bit and resets the counter to less than MAX. The reset value to the counter is not clocked immediately so the overflow status bit will flip 'high (1)' and generate another PMI (if enabled) after which the reset value gets clocked into the counter. Therefore, software will get the interrupt, read the overflow status bit '1 for bit 34 while the counter value is less than MAX. Software should ignore this case.",
"EventCode": "0x00",
"Counter": "Fixed counter 3",
"UMask": "0x3",
"EventName": "CPU_CLK_UNHALTED.REF_TSC",
"SampleAfterValue": "2000003",
"BriefDescription": "Reference cycles when the core is not in halt state.",
"CounterHTOff": "Fixed counter 3"
},
{
"PublicDescription": "This is an architectural event that counts the number of thread cycles while the thread is not in a halt state. The thread enters the halt state when it is running the HLT instruction. The core frequency may change from time to time due to power or thermal throttling. For this reason, this event may have a changing ratio with regards to wall clock time.",
"EventCode": "0x3C",
"Counter": "0,1,2,3",
"UMask": "0x0",
"EventName": "CPU_CLK_UNHALTED.THREAD_P",
"SampleAfterValue": "2000003",
"BriefDescription": "Thread cycles when thread is not in halt state",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xE6",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "BACLEARS.ANY",
"SampleAfterValue": "100003",
"BriefDescription": "Counts the total number when the front end is resteered, mainly when the BPU cannot provide a correct prediction and this is corrected by other branch handling mechanisms at the front end.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xA8",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "LSD.UOPS",
"SampleAfterValue": "2000003",
"BriefDescription": "Number of Uops delivered by the LSD.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts stalls occured due to changing prefix length (66, 67 or REX.W when they change the length of the decoded instruction). Occurrences counting is proportional to the number of prefixes in a 16B-line. This may result in the following penalties: three-cycle penalty for each LCP in a 16-byte chunk.",
"EventCode": "0x87",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "ILD_STALL.LCP",
"SampleAfterValue": "2000003",
"BriefDescription": "Stalls caused by changing prefix length of the instruction.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "Cycles checkpoints in Resource Allocation Table (RAT) are recovering from JEClear or machine clear.",
"EventCode": "0x0D",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "INT_MISC.RECOVERY_CYCLES",
"SampleAfterValue": "2000003",
"BriefDescription": "Core cycles the allocator was stalled due to recovery from earlier clear event for this thread (e.g. misprediction or memory nuke)",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0x0D",
"Counter": "0,1,2,3",
"UMask": "0x80",
"EventName": "INT_MISC.CLEAR_RESTEER_CYCLES",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles the issue-stage is waiting for front-end to fetch from resteered path following branch misprediction or machine clear events.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts resource-related stall cycles. Reasons for stalls can be as follows:\n - *any* u-arch structure got full (LB, SB, RS, ROB, BOB, LM, Physical Register Reclaim Table (PRRT), or Physical History Table (PHT) slots)\n - *any* u-arch structure got empty (like INT/SIMD FreeLists)\n - FPU control word (FPCW), MXCSR\nand others. This counts cycles that the pipeline backend blocked uop delivery from the front end.",
"EventCode": "0xA2",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "RESOURCE_STALLS.ANY",
"SampleAfterValue": "2000003",
"BriefDescription": "Resource-related stall cycles",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts stall cycles caused by the store buffer (SB) overflow (excluding draining from synch). This counts cycles that the pipeline backend blocked uop delivery from the front end.",
"EventCode": "0xA2",
"Counter": "0,1,2,3",
"UMask": "0x8",
"EventName": "RESOURCE_STALLS.SB",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles stalled due to no store buffers available. (not including draining form sync).",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts the number of Uops issued by the Resource Allocation Table (RAT) to the reservation station (RS).",
"EventCode": "0x0E",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "UOPS_ISSUED.ANY",
"SampleAfterValue": "2000003",
"BriefDescription": "Uops that Resource Allocation Table (RAT) issues to Reservation Station (RS)",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0x0E",
"Counter": "0,1,2,3",
"UMask": "0x20",
"EventName": "UOPS_ISSUED.SLOW_LEA",
"SampleAfterValue": "2000003",
"BriefDescription": "Number of slow LEA uops being allocated. A uop is generally considered SlowLea if it has 3 sources (e.g. 2 sources + immediate) regardless if as a result of LEA instruction or not.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts cycles during which the Resource Allocation Table (RAT) does not issue any Uops to the reservation station (RS) for the current thread.",
"EventCode": "0x0E",
"Invert": "1",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "UOPS_ISSUED.STALL_CYCLES",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles when Resource Allocation Table (RAT) does not issue Uops to Reservation Station (RS) for the thread",
"CounterMask": "1",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts cycles during which the reservation station (RS) is empty for the thread.\nNote: In ST-mode, not active thread should drive 0. This is usually caused by severely costly branch mispredictions, or allocator/FE issues.",
"EventCode": "0x5E",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "RS_EVENTS.EMPTY_CYCLES",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles when Reservation Station (RS) is empty for the thread",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0x5E",
"Invert": "1",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EdgeDetect": "1",
"EventName": "RS_EVENTS.EMPTY_END",
"SampleAfterValue": "2000003",
"BriefDescription": "Counts end of periods where the Reservation Station (RS) was empty. Could be useful to precisely locate Frontend Latency Bound issues.",
"CounterMask": "1",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "Increments when an entry is added to the Last Branch Record (LBR) array (or removed from the array in case of RETURNs in call stack mode). The event requires LBR enable via IA32_DEBUGCTL MSR and branch type selection via MSR_LBR_SELECT.",
"EventCode": "0xCC",
"Counter": "0,1,2,3",
"UMask": "0x20",
"EventName": "ROB_MISC_EVENTS.LBR_INSERTS",
"SampleAfterValue": "2000003",
"BriefDescription": "Increments whenever there is an update to the LBR array.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "Number of machine clears (nukes) of any type.",
"EventCode": "0xC3",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EdgeDetect": "1",
"EventName": "MACHINE_CLEARS.COUNT",
"SampleAfterValue": "100003",
"BriefDescription": "Number of machine clears (nukes) of any type. ",
"CounterMask": "1",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts self-modifying code (SMC) detected, which causes a machine clear.",
"EventCode": "0xC3",
"Counter": "0,1,2,3",
"UMask": "0x4",
"EventName": "MACHINE_CLEARS.SMC",
"SampleAfterValue": "100003",
"BriefDescription": "Self-modifying code (SMC) detected.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts the number of instructions (EOMs) retired. Counting covers macro-fused instructions individually (that is, increments by two).",
"EventCode": "0xC0",
"Counter": "0,1,2,3",
"UMask": "0x0",
"Errata": "SKL091, SKL044",
"EventName": "INST_RETIRED.ANY_P",
"SampleAfterValue": "2000003",
"BriefDescription": "Number of instructions retired. General Counter - architectural event",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PEBS": "2",
"PublicDescription": "This is a precise version (that is, uses PEBS) of the event that counts instructions retired.",
"EventCode": "0xC0",
"Counter": "1",
"UMask": "0x1",
"Errata": "SKL091, SKL044",
"EventName": "INST_RETIRED.PREC_DIST",
"SampleAfterValue": "2000003",
"BriefDescription": "Precise instruction retired event with HW to reduce effect of PEBS shadow in IP distribution",
"CounterHTOff": "1"
},
{
"PublicDescription": "This is a non-precise version (that is, does not use PEBS) of the event that counts the number of retirement slots used.",
"EventCode": "0xC2",
"Counter": "0,1,2,3",
"UMask": "0x2",
"EventName": "UOPS_RETIRED.RETIRE_SLOTS",
"SampleAfterValue": "2000003",
"BriefDescription": "Retirement slots used.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This is a non-precise version (that is, does not use PEBS) of the event that counts cycles without actually retired uops.",
"EventCode": "0xC2",
"Invert": "1",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "UOPS_RETIRED.STALL_CYCLES",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles without actually retired uops.",
"CounterMask": "1",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "Number of cycles using always true condition (uops_ret < 16) applied to non PEBS uops retired event.",
"EventCode": "0xC2",
"Invert": "1",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "UOPS_RETIRED.TOTAL_CYCLES",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles with less than 10 actually retired uops.",
"CounterMask": "10",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PEBS": "1",
"PublicDescription": "This is a non-precise version (that is, does not use PEBS) of the event that counts conditional branch instructions retired.",
"EventCode": "0xC4",
"Counter": "0,1,2,3",
"UMask": "0x1",
"Errata": "SKL091",
"EventName": "BR_INST_RETIRED.CONDITIONAL",
"SampleAfterValue": "400009",
"BriefDescription": "Conditional branch instructions retired.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PEBS": "1",
"PublicDescription": "This is a non-precise version (that is, does not use PEBS) of the event that counts both direct and indirect near call instructions retired.",
"EventCode": "0xC4",
"Counter": "0,1,2,3",
"UMask": "0x2",
"Errata": "SKL091",
"EventName": "BR_INST_RETIRED.NEAR_CALL",
"SampleAfterValue": "100007",
"BriefDescription": "Direct and indirect near call instructions retired.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts all (macro) branch instructions retired.",
"EventCode": "0xC4",
"Counter": "0,1,2,3",
"UMask": "0x0",
"Errata": "SKL091",
"EventName": "BR_INST_RETIRED.ALL_BRANCHES",
"SampleAfterValue": "400009",
"BriefDescription": "All (macro) branch instructions retired.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PEBS": "1",
"PublicDescription": "This is a non-precise version (that is, does not use PEBS) of the event that counts return instructions retired.",
"EventCode": "0xC4",
"Counter": "0,1,2,3",
"UMask": "0x8",
"Errata": "SKL091",
"EventName": "BR_INST_RETIRED.NEAR_RETURN",
"SampleAfterValue": "100007",
"BriefDescription": "Return instructions retired.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This is a non-precise version (that is, does not use PEBS) of the event that counts not taken branch instructions retired.",
"EventCode": "0xC4",
"Counter": "0,1,2,3",
"UMask": "0x10",
"Errata": "SKL091",
"EventName": "BR_INST_RETIRED.NOT_TAKEN",
"SampleAfterValue": "400009",
"BriefDescription": "Not taken branch instructions retired.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PEBS": "1",
"PublicDescription": "This is a non-precise version (that is, does not use PEBS) of the event that counts taken branch instructions retired.",
"EventCode": "0xC4",
"Counter": "0,1,2,3",
"UMask": "0x20",
"Errata": "SKL091",
"EventName": "BR_INST_RETIRED.NEAR_TAKEN",
"SampleAfterValue": "400009",
"BriefDescription": "Taken branch instructions retired.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PEBS": "1",
"PublicDescription": "This is a non-precise version (that is, does not use PEBS) of the event that counts far branch instructions retired.",
"EventCode": "0xC4",
"Counter": "0,1,2,3",
"UMask": "0x40",
"Errata": "SKL091",
"EventName": "BR_INST_RETIRED.FAR_BRANCH",
"SampleAfterValue": "100007",
"BriefDescription": "Far branch instructions retired.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PEBS": "2",
"PublicDescription": "This is a precise version of BR_INST_RETIRED.ALL_BRANCHES that counts all (macro) branch instructions retired.",
"EventCode": "0xC4",
"Counter": "0,1,2,3",
"UMask": "0x4",
"Errata": "SKL091",
"EventName": "BR_INST_RETIRED.ALL_BRANCHES_PEBS",
"SampleAfterValue": "400009",
"BriefDescription": "All (macro) branch instructions retired. ",
"CounterHTOff": "0,1,2,3"
},
{
"PEBS": "1",
"PublicDescription": "This is a non-precise version (that is, does not use PEBS) of the event that counts mispredicted conditional branch instructions retired.",
"EventCode": "0xC5",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "BR_MISP_RETIRED.CONDITIONAL",
"SampleAfterValue": "400009",
"BriefDescription": "Mispredicted conditional branch instructions retired.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PEBS": "1",
"PublicDescription": "This event counts both taken and not taken retired mispredicted direct and indirect near calls, including both register and memory indirect.",
"EventCode": "0xC5",
"Counter": "0,1,2,3",
"UMask": "0x2",
"EventName": "BR_MISP_RETIRED.NEAR_CALL",
"SampleAfterValue": "400009",
"BriefDescription": "Mispredicted direct and indirect near call instructions retired.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts all mispredicted macro branch instructions retired.",
"EventCode": "0xC5",
"Counter": "0,1,2,3",
"UMask": "0x0",
"EventName": "BR_MISP_RETIRED.ALL_BRANCHES",
"SampleAfterValue": "400009",
"BriefDescription": "All mispredicted macro branch instructions retired.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PEBS": "1",
"EventCode": "0xC5",
"Counter": "0,1,2,3",
"UMask": "0x20",
"EventName": "BR_MISP_RETIRED.NEAR_TAKEN",
"SampleAfterValue": "400009",
"BriefDescription": "Number of near branch instructions retired that were mispredicted and taken.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PEBS": "2",
"PublicDescription": "This is a precise version of BR_MISP_RETIRED.ALL_BRANCHES that counts all mispredicted macro branch instructions retired.",
"EventCode": "0xC5",
"Counter": "0,1,2,3",
"UMask": "0x4",
"EventName": "BR_MISP_RETIRED.ALL_BRANCHES_PEBS",
"SampleAfterValue": "400009",
"BriefDescription": "Mispredicted macro branch instructions retired. ",
"CounterHTOff": "0,1,2,3"
},
{
"PublicDescription": "Number of uops to be executed per-thread each cycle.",
"EventCode": "0xB1",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "UOPS_EXECUTED.THREAD",
"SampleAfterValue": "2000003",
"BriefDescription": "Counts the number of uops to be executed per-thread each cycle.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "Number of uops executed from any thread.",
"EventCode": "0xB1",
"Counter": "0,1,2,3",
"UMask": "0x2",
"EventName": "UOPS_EXECUTED.CORE",
"SampleAfterValue": "2000003",
"BriefDescription": "Number of uops executed on the core.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xB1",
"Counter": "0,1,2,3",
"UMask": "0x10",
"EventName": "UOPS_EXECUTED.X87",
"SampleAfterValue": "2000003",
"BriefDescription": "Counts the number of x87 uops dispatched.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts cycles during which no uops were dispatched from the Reservation Station (RS) per thread.",
"EventCode": "0xB1",
"Invert": "1",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "UOPS_EXECUTED.STALL_CYCLES",
"SampleAfterValue": "2000003",
"BriefDescription": "Counts number of cycles no uops were dispatched to be executed on this thread.",
"CounterMask": "1",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "Cycles where at least 1 uop was executed per-thread.",
"EventCode": "0xB1",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "UOPS_EXECUTED.CYCLES_GE_1_UOP_EXEC",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles where at least 1 uop was executed per-thread",
"CounterMask": "1",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "Cycles where at least 2 uops were executed per-thread.",
"EventCode": "0xB1",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "UOPS_EXECUTED.CYCLES_GE_2_UOPS_EXEC",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles where at least 2 uops were executed per-thread",
"CounterMask": "2",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "Cycles where at least 3 uops were executed per-thread.",
"EventCode": "0xB1",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "UOPS_EXECUTED.CYCLES_GE_3_UOPS_EXEC",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles where at least 3 uops were executed per-thread",
"CounterMask": "3",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "Cycles where at least 4 uops were executed per-thread.",
"EventCode": "0xB1",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "UOPS_EXECUTED.CYCLES_GE_4_UOPS_EXEC",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles where at least 4 uops were executed per-thread",
"CounterMask": "4",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xA6",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "EXE_ACTIVITY.EXE_BOUND_0_PORTS",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles where no uops were executed, the Reservation Station was not empty, the Store Buffer was full and there was no outstanding load.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xA6",
"Counter": "0,1,2,3",
"UMask": "0x2",
"EventName": "EXE_ACTIVITY.1_PORTS_UTIL",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles total of 1 uop is executed on all ports and Reservation Station was not empty.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xA6",
"Counter": "0,1,2,3",
"UMask": "0x4",
"EventName": "EXE_ACTIVITY.2_PORTS_UTIL",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles total of 2 uops are executed on all ports and Reservation Station was not empty.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xA6",
"Counter": "0,1,2,3",
"UMask": "0x8",
"EventName": "EXE_ACTIVITY.3_PORTS_UTIL",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles total of 3 uops are executed on all ports and Reservation Station was not empty.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xA6",
"Counter": "0,1,2,3",
"UMask": "0x10",
"EventName": "EXE_ACTIVITY.4_PORTS_UTIL",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles total of 4 uops are executed on all ports and Reservation Station was not empty.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xA6",
"Counter": "0,1,2,3",
"UMask": "0x40",
"EventName": "EXE_ACTIVITY.BOUND_ON_STORES",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles where the Store Buffer was full and no outstanding load.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts, on the per-thread basis, cycles during which uops are dispatched from the Reservation Station (RS) to port 0.",
"EventCode": "0xA1",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "UOPS_DISPATCHED_PORT.PORT_0",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles per thread when uops are executed in port 0",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts, on the per-thread basis, cycles during which uops are dispatched from the Reservation Station (RS) to port 1.",
"EventCode": "0xA1",
"Counter": "0,1,2,3",
"UMask": "0x2",
"EventName": "UOPS_DISPATCHED_PORT.PORT_1",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles per thread when uops are executed in port 1",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts, on the per-thread basis, cycles during which uops are dispatched from the Reservation Station (RS) to port 2.",
"EventCode": "0xA1",
"Counter": "0,1,2,3",
"UMask": "0x4",
"EventName": "UOPS_DISPATCHED_PORT.PORT_2",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles per thread when uops are executed in port 2",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts, on the per-thread basis, cycles during which uops are dispatched from the Reservation Station (RS) to port 3.",
"EventCode": "0xA1",
"Counter": "0,1,2,3",
"UMask": "0x8",
"EventName": "UOPS_DISPATCHED_PORT.PORT_3",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles per thread when uops are executed in port 3",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts, on the per-thread basis, cycles during which uops are dispatched from the Reservation Station (RS) to port 4.",
"EventCode": "0xA1",
"Counter": "0,1,2,3",
"UMask": "0x10",
"EventName": "UOPS_DISPATCHED_PORT.PORT_4",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles per thread when uops are executed in port 4",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts, on the per-thread basis, cycles during which uops are dispatched from the Reservation Station (RS) to port 5.",
"EventCode": "0xA1",
"Counter": "0,1,2,3",
"UMask": "0x20",
"EventName": "UOPS_DISPATCHED_PORT.PORT_5",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles per thread when uops are executed in port 5",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts, on the per-thread basis, cycles during which uops are dispatched from the Reservation Station (RS) to port 6.",
"EventCode": "0xA1",
"Counter": "0,1,2,3",
"UMask": "0x40",
"EventName": "UOPS_DISPATCHED_PORT.PORT_6",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles per thread when uops are executed in port 6",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts, on the per-thread basis, cycles during which uops are dispatched from the Reservation Station (RS) to port 7.",
"EventCode": "0xA1",
"Counter": "0,1,2,3",
"UMask": "0x80",
"EventName": "UOPS_DISPATCHED_PORT.PORT_7",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles per thread when uops are executed in port 7",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xA3",
"Counter": "0,1,2,3",
"UMask": "0x4",
"EventName": "CYCLE_ACTIVITY.STALLS_TOTAL",
"SampleAfterValue": "2000003",
"BriefDescription": "Total execution stalls.",
"CounterMask": "4",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xA3",
"Counter": "0,1,2,3",
"UMask": "0x8",
"EventName": "CYCLE_ACTIVITY.CYCLES_L1D_MISS",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles while L1 cache miss demand load is outstanding.",
"CounterMask": "8",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xA3",
"Counter": "0,1,2,3",
"UMask": "0xc",
"EventName": "CYCLE_ACTIVITY.STALLS_L1D_MISS",
"SampleAfterValue": "2000003",
"BriefDescription": "Execution stalls while L1 cache miss demand load is outstanding.",
"CounterMask": "12",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts all not software-prefetch load dispatches that hit the fill buffer (FB) allocated for the software prefetch. It can also be incremented by some lock instructions. So it should only be used with profiling so that the locks can be excluded by asm inspection of the nearby instructions.",
"EventCode": "0x4C",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "LOAD_HIT_PRE.SW_PF",
"SampleAfterValue": "100003",
"BriefDescription": "Demand load dispatches that hit L1D fill buffer (FB) allocated for software prefetch.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts how many times the load operation got the true Block-on-Store blocking code preventing store forwarding. This includes cases when:\n - preceding store conflicts with the load (incomplete overlap)\n\n - store forwarding is impossible due to u-arch limitations\n\n - preceding lock RMW operations are not forwarded\n\n - store has the no-forward bit set (uncacheable/page-split/masked stores)\n\n - all-blocking stores are used (mostly, fences and port I/O)\n\nand others.\nThe most common case is a load blocked due to its address range overlapping with a preceding smaller uncompleted store. Note: This event does not take into account cases of out-of-SW-control (for example, SbTailHit), unknown physical STA, and cases of blocking loads on store due to being non-WB memory type or a lock. These cases are covered by other events.\nSee the table of not supported store forwards in the Optimization Guide.",
"EventCode": "0x03",
"Counter": "0,1,2,3",
"UMask": "0x2",
"EventName": "LD_BLOCKS.STORE_FORWARD",
"SampleAfterValue": "100003",
"BriefDescription": "Loads blocked by overlapping with store buffer that cannot be forwarded .",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "The number of times that split load operations are temporarily blocked because all resources for handling the split accesses are in use.",
"EventCode": "0x03",
"Counter": "0,1,2,3",
"UMask": "0x8",
"EventName": "LD_BLOCKS.NO_SR",
"SampleAfterValue": "100003",
"BriefDescription": "The number of times that split load operations are temporarily blocked because all resources for handling the split accesses are in use",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts false dependencies in MOB when the partial comparison upon loose net check and dependency was resolved by the Enhanced Loose net mechanism. This may not result in high performance penalties. Loose net checks can fail when loads and stores are 4k aliased.",
"EventCode": "0x07",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "LD_BLOCKS_PARTIAL.ADDRESS_ALIAS",
"SampleAfterValue": "100003",
"BriefDescription": "False dependencies in MOB due to partial compare on address.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xA3",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "CYCLE_ACTIVITY.CYCLES_L2_MISS",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles while L2 cache miss demand load is outstanding.",
"CounterMask": "1",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xA3",
"Counter": "0,1,2,3",
"UMask": "0x5",
"EventName": "CYCLE_ACTIVITY.STALLS_L2_MISS",
"SampleAfterValue": "2000003",
"BriefDescription": "Execution stalls while L2 cache miss demand load is outstanding.",
"CounterMask": "5",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xA3",
"Counter": "0,1,2,3",
"UMask": "0x10",
"EventName": "CYCLE_ACTIVITY.CYCLES_MEM_ANY",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles while memory subsystem has an outstanding load.",
"CounterMask": "16",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xA3",
"Counter": "0,1,2,3",
"UMask": "0x14",
"EventName": "CYCLE_ACTIVITY.STALLS_MEM_ANY",
"SampleAfterValue": "2000003",
"BriefDescription": "Execution stalls while memory subsystem has an outstanding load.",
"CounterMask": "20",
"CounterHTOff": "0,1,2,3"
},
{
"EventCode": "0x3C",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "CPU_CLK_THREAD_UNHALTED.REF_XCLK",
"SampleAfterValue": "2503",
"BriefDescription": "Core crystal clock cycles when the thread is unhalted.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0x3C",
"Counter": "0,1,2,3",
"UMask": "0x2",
"EventName": "CPU_CLK_THREAD_UNHALTED.ONE_THREAD_ACTIVE",
"SampleAfterValue": "2000003",
"BriefDescription": "Core crystal clock cycles when this thread is unhalted and the other thread is halted.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PEBS": "2",
"PublicDescription": "Number of cycles using an always true condition applied to PEBS instructions retired event. (inst_ret< 16)",
"EventCode": "0xC0",
"Invert": "1",
"Counter": "0,2,3",
"UMask": "0x1",
"Errata": "SKL091, SKL044",
"EventName": "INST_RETIRED.TOTAL_CYCLES_PS",
"SampleAfterValue": "2000003",
"BriefDescription": "Number of cycles using always true condition applied to PEBS instructions retired event.",
"CounterMask": "10",
"CounterHTOff": "0,2,3"
},
{
"EventCode": "0x14",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "ARITH.DIVIDER_ACTIVE",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles when divide unit is busy executing divide or square root operations. Accounts for integer and floating-point operations.",
"CounterMask": "1",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xA8",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "LSD.CYCLES_ACTIVE",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles Uops delivered by the LSD, but didn't come from the decoder.",
"CounterMask": "1",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xA8",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "LSD.CYCLES_4_UOPS",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles 4 Uops delivered by the LSD, but didn't come from the decoder.",
"CounterMask": "4",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xC1",
"Counter": "0,1,2,3",
"UMask": "0x3f",
"EventName": "OTHER_ASSISTS.ANY",
"SampleAfterValue": "100003",
"BriefDescription": "Number of times a microcode assist is invoked by HW other than FP-assist. Examples include AD (page Access Dirty) and AVX* related assists.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts the number of Blend Uops issued by the Resource Allocation Table (RAT) to the reservation station (RS) in order to preserve upper bits of vector registers. Starting the Skylake microarchitecture, these Blend uops are needed since every Intel SSE instruction executed in Dirty Upper State needs to preserve bits 128-255 of the destination register.\r\nFor more information, refer to ?Mixing Intel AVX and Intel SSE Code? section of the Optimization Guide.",
"EventCode": "0x0E",
"Counter": "0,1,2,3",
"UMask": "0x2",
"EventName": "UOPS_ISSUED.VECTOR_WIDTH_MISMATCH",
"SampleAfterValue": "2000003",
"BriefDescription": "Uops inserted at issue-stage in order to preserve upper bits of vector registers.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0x00",
"Counter": "Fixed counter 2",
"UMask": "0x2",
"AnyThread": "1",
"EventName": "CPU_CLK_UNHALTED.THREAD_ANY",
"SampleAfterValue": "2000003",
"BriefDescription": "Core cycles when at least one thread on the physical core is not in halt state.",
"CounterHTOff": "Fixed counter 2"
},
{
"EventCode": "0x3C",
"Counter": "0,1,2,3",
"UMask": "0x0",
"AnyThread": "1",
"EventName": "CPU_CLK_UNHALTED.THREAD_P_ANY",
"SampleAfterValue": "2000003",
"BriefDescription": "Core cycles when at least one thread on the physical core is not in halt state.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0x3C",
"Counter": "0,1,2,3",
"UMask": "0x1",
"AnyThread": "1",
"EventName": "CPU_CLK_THREAD_UNHALTED.REF_XCLK_ANY",
"SampleAfterValue": "2503",
"BriefDescription": "Core crystal clock cycles when at least one thread on the physical core is unhalted.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0x0D",
"Counter": "0,1,2,3",
"UMask": "0x1",
"AnyThread": "1",
"EventName": "INT_MISC.RECOVERY_CYCLES_ANY",
"SampleAfterValue": "2000003",
"BriefDescription": "Core cycles the allocator was stalled due to recovery from earlier clear event for any thread running on the physical core (e.g. misprediction or memory nuke).",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xB1",
"Counter": "0,1,2,3",
"UMask": "0x2",
"EventName": "UOPS_EXECUTED.CORE_CYCLES_GE_1",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles at least 1 micro-op is executed from any thread on physical core.",
"CounterMask": "1",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xB1",
"Counter": "0,1,2,3",
"UMask": "0x2",
"EventName": "UOPS_EXECUTED.CORE_CYCLES_GE_2",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles at least 2 micro-op is executed from any thread on physical core.",
"CounterMask": "2",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xB1",
"Counter": "0,1,2,3",
"UMask": "0x2",
"EventName": "UOPS_EXECUTED.CORE_CYCLES_GE_3",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles at least 3 micro-op is executed from any thread on physical core.",
"CounterMask": "3",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xB1",
"Counter": "0,1,2,3",
"UMask": "0x2",
"EventName": "UOPS_EXECUTED.CORE_CYCLES_GE_4",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles at least 4 micro-op is executed from any thread on physical core.",
"CounterMask": "4",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0xB1",
"Invert": "1",
"Counter": "0,1,2,3",
"UMask": "0x2",
"EventName": "UOPS_EXECUTED.CORE_CYCLES_NONE",
"SampleAfterValue": "2000003",
"BriefDescription": "Cycles with no micro-ops executed from any thread on physical core.",
"CounterMask": "1",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"PublicDescription": "This event counts when the Current Privilege Level (CPL) transitions from ring 1, 2 or 3 to ring 0 (Kernel).",
"EventCode": "0x3C",
"Counter": "0,1,2,3",
"UMask": "0x0",
"EdgeDetect": "1",
"EventName": "CPU_CLK_UNHALTED.RING0_TRANS",
"SampleAfterValue": "100007",
"BriefDescription": "Counts when there is a transition from ring 1, 2 or 3 to ring 0.",
"CounterMask": "1",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0x3C",
"Counter": "0,1,2,3",
"UMask": "0x1",
"EventName": "CPU_CLK_UNHALTED.REF_XCLK",
"SampleAfterValue": "2503",
"BriefDescription": "Core crystal clock cycles when the thread is unhalted.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0x3C",
"Counter": "0,1,2,3",
"UMask": "0x1",
"AnyThread": "1",
"EventName": "CPU_CLK_UNHALTED.REF_XCLK_ANY",
"SampleAfterValue": "2503",
"BriefDescription": "Core crystal clock cycles when at least one thread on the physical core is unhalted.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
},
{
"EventCode": "0x3C",
"Counter": "0,1,2,3",
"UMask": "0x2",
"EventName": "CPU_CLK_UNHALTED.ONE_THREAD_ACTIVE",
"SampleAfterValue": "2503",
"BriefDescription": "Core crystal clock cycles when this thread is unhalted and the other thread is halted.",
"CounterHTOff": "0,1,2,3,4,5,6,7"
}
]
|