summaryrefslogtreecommitdiffstats
path: root/drivers/thermal/armada_thermal.c
blob: 4c275ec10ac53d85f2b2992b6f0d845e3aa6d5db (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
/*
 * Marvell EBU Armada SoCs thermal sensor driver
 *
 * Copyright (C) 2013 Marvell
 *
 * This software is licensed under the terms of the GNU General Public
 * License version 2, as published by the Free Software Foundation, and
 * may be copied, distributed, and modified under those terms.
 *
 * This program is distributed in the hope that it will be useful,
 * but WITHOUT ANY WARRANTY; without even the implied warranty of
 * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
 * GNU General Public License for more details.
 *
 */
#include <linux/device.h>
#include <linux/err.h>
#include <linux/io.h>
#include <linux/kernel.h>
#include <linux/of.h>
#include <linux/module.h>
#include <linux/delay.h>
#include <linux/platform_device.h>
#include <linux/of_device.h>
#include <linux/thermal.h>
#include <linux/iopoll.h>

/* Thermal Manager Control and Status Register */
#define PMU_TDC0_SW_RST_MASK		(0x1 << 1)
#define PMU_TM_DISABLE_OFFS		0
#define PMU_TM_DISABLE_MASK		(0x1 << PMU_TM_DISABLE_OFFS)
#define PMU_TDC0_REF_CAL_CNT_OFFS	11
#define PMU_TDC0_REF_CAL_CNT_MASK	(0x1ff << PMU_TDC0_REF_CAL_CNT_OFFS)
#define PMU_TDC0_OTF_CAL_MASK		(0x1 << 30)
#define PMU_TDC0_START_CAL_MASK		(0x1 << 25)

#define A375_UNIT_CONTROL_SHIFT		27
#define A375_UNIT_CONTROL_MASK		0x7
#define A375_READOUT_INVERT		BIT(15)
#define A375_HW_RESETn			BIT(8)

/* Legacy bindings */
#define LEGACY_CONTROL_MEM_LEN		0x4

/* Current bindings with the 2 control registers under the same memory area */
#define LEGACY_CONTROL1_OFFSET		0x0
#define CONTROL0_OFFSET			0x0
#define CONTROL1_OFFSET			0x4

/* Errata fields */
#define CONTROL0_TSEN_TC_TRIM_MASK	0x7
#define CONTROL0_TSEN_TC_TRIM_VAL	0x3

/* TSEN refers to the temperature sensors within the AP */
#define CONTROL0_TSEN_START		BIT(0)
#define CONTROL0_TSEN_RESET		BIT(1)
#define CONTROL0_TSEN_ENABLE		BIT(2)

/* EXT_TSEN refers to the external temperature sensors, out of the AP */
#define CONTROL1_EXT_TSEN_SW_RESET	BIT(7)
#define CONTROL1_EXT_TSEN_HW_RESETn	BIT(8)

#define STATUS_POLL_PERIOD_US		1000
#define STATUS_POLL_TIMEOUT_US		100000

struct armada_thermal_data;

/* Marvell EBU Thermal Sensor Dev Structure */
struct armada_thermal_priv {
	void __iomem *status;
	void __iomem *control0;
	void __iomem *control1;
	struct armada_thermal_data *data;
};

struct armada_thermal_data {
	/* Initialize the sensor */
	void (*init_sensor)(struct platform_device *pdev,
			    struct armada_thermal_priv *);

	/* Test for a valid sensor value (optional) */
	bool (*is_valid)(struct armada_thermal_priv *);

	/* Formula coeficients: temp = (b - m * reg) / div */
	s64 coef_b;
	s64 coef_m;
	u32 coef_div;
	bool inverted;
	bool signed_sample;

	/* Register shift and mask to access the sensor temperature */
	unsigned int temp_shift;
	unsigned int temp_mask;
	u32 is_valid_bit;
	bool needs_control0;
};

static void armadaxp_init_sensor(struct platform_device *pdev,
				 struct armada_thermal_priv *priv)
{
	u32 reg;

	reg = readl_relaxed(priv->control1);
	reg |= PMU_TDC0_OTF_CAL_MASK;
	writel(reg, priv->control1);

	/* Reference calibration value */
	reg &= ~PMU_TDC0_REF_CAL_CNT_MASK;
	reg |= (0xf1 << PMU_TDC0_REF_CAL_CNT_OFFS);
	writel(reg, priv->control1);

	/* Reset the sensor */
	reg = readl_relaxed(priv->control1);
	writel((reg | PMU_TDC0_SW_RST_MASK), priv->control1);

	writel(reg, priv->control1);

	/* Enable the sensor */
	reg = readl_relaxed(priv->status);
	reg &= ~PMU_TM_DISABLE_MASK;
	writel(reg, priv->status);
}

static void armada370_init_sensor(struct platform_device *pdev,
				  struct armada_thermal_priv *priv)
{
	u32 reg;

	reg = readl_relaxed(priv->control1);
	reg |= PMU_TDC0_OTF_CAL_MASK;
	writel(reg, priv->control1);

	/* Reference calibration value */
	reg &= ~PMU_TDC0_REF_CAL_CNT_MASK;
	reg |= (0xf1 << PMU_TDC0_REF_CAL_CNT_OFFS);
	writel(reg, priv->control1);

	reg &= ~PMU_TDC0_START_CAL_MASK;
	writel(reg, priv->control1);

	msleep(10);
}

static void armada375_init_sensor(struct platform_device *pdev,
				  struct armada_thermal_priv *priv)
{
	u32 reg;

	reg = readl(priv->control1);
	reg &= ~(A375_UNIT_CONTROL_MASK << A375_UNIT_CONTROL_SHIFT);
	reg &= ~A375_READOUT_INVERT;
	reg &= ~A375_HW_RESETn;

	writel(reg, priv->control1);
	msleep(20);

	reg |= A375_HW_RESETn;
	writel(reg, priv->control1);
	msleep(50);
}

static void armada_wait_sensor_validity(struct armada_thermal_priv *priv)
{
	u32 reg;

	readl_relaxed_poll_timeout(priv->status, reg,
				   reg & priv->data->is_valid_bit,
				   STATUS_POLL_PERIOD_US,
				   STATUS_POLL_TIMEOUT_US);
}

static void armada380_init_sensor(struct platform_device *pdev,
				  struct armada_thermal_priv *priv)
{
	u32 reg = readl_relaxed(priv->control1);

	/* Disable the HW/SW reset */
	reg |= CONTROL1_EXT_TSEN_HW_RESETn;
	reg &= ~CONTROL1_EXT_TSEN_SW_RESET;
	writel(reg, priv->control1);

	/* Set Tsen Tc Trim to correct default value (errata #132698) */
	if (priv->control0) {
		reg = readl_relaxed(priv->control0);
		reg &= ~CONTROL0_TSEN_TC_TRIM_MASK;
		reg |= CONTROL0_TSEN_TC_TRIM_VAL;
		writel(reg, priv->control0);
	}

	/* Wait the sensors to be valid or the core will warn the user */
	armada_wait_sensor_validity(priv);
}

static void armada_ap806_init_sensor(struct platform_device *pdev,
				     struct armada_thermal_priv *priv)
{
	u32 reg;

	reg = readl_relaxed(priv->control0);
	reg &= ~CONTROL0_TSEN_RESET;
	reg |= CONTROL0_TSEN_START | CONTROL0_TSEN_ENABLE;
	writel(reg, priv->control0);

	/* Wait the sensors to be valid or the core will warn the user */
	armada_wait_sensor_validity(priv);
}

static bool armada_is_valid(struct armada_thermal_priv *priv)
{
	u32 reg = readl_relaxed(priv->status);

	return reg & priv->data->is_valid_bit;
}

static int armada_get_temp(struct thermal_zone_device *thermal,
			   int *temp)
{
	struct armada_thermal_priv *priv = thermal->devdata;
	u32 reg, div;
	s64 sample, b, m;

	/* Valid check */
	if (priv->data->is_valid && !priv->data->is_valid(priv)) {
		dev_err(&thermal->device,
			"Temperature sensor reading not valid\n");
		return -EIO;
	}

	reg = readl_relaxed(priv->status);
	reg = (reg >> priv->data->temp_shift) & priv->data->temp_mask;
	if (priv->data->signed_sample)
		/* The most significant bit is the sign bit */
		sample = sign_extend32(reg, fls(priv->data->temp_mask) - 1);
	else
		sample = reg;

	/* Get formula coeficients */
	b = priv->data->coef_b;
	m = priv->data->coef_m;
	div = priv->data->coef_div;

	if (priv->data->inverted)
		*temp = div_s64((m * sample) - b, div);
	else
		*temp = div_s64(b - (m * sample), div);

	return 0;
}

static struct thermal_zone_device_ops ops = {
	.get_temp = armada_get_temp,
};

static const struct armada_thermal_data armadaxp_data = {
	.init_sensor = armadaxp_init_sensor,
	.temp_shift = 10,
	.temp_mask = 0x1ff,
	.coef_b = 3153000000ULL,
	.coef_m = 10000000ULL,
	.coef_div = 13825,
};

static const struct armada_thermal_data armada370_data = {
	.is_valid = armada_is_valid,
	.init_sensor = armada370_init_sensor,
	.is_valid_bit = BIT(9),
	.temp_shift = 10,
	.temp_mask = 0x1ff,
	.coef_b = 3153000000ULL,
	.coef_m = 10000000ULL,
	.coef_div = 13825,
};

static const struct armada_thermal_data armada375_data = {
	.is_valid = armada_is_valid,
	.init_sensor = armada375_init_sensor,
	.is_valid_bit = BIT(10),
	.temp_shift = 0,
	.temp_mask = 0x1ff,
	.coef_b = 3171900000ULL,
	.coef_m = 10000000ULL,
	.coef_div = 13616,
	.needs_control0 = true,
};

static const struct armada_thermal_data armada380_data = {
	.is_valid = armada_is_valid,
	.init_sensor = armada380_init_sensor,
	.is_valid_bit = BIT(10),
	.temp_shift = 0,
	.temp_mask = 0x3ff,
	.coef_b = 1172499100ULL,
	.coef_m = 2000096ULL,
	.coef_div = 4201,
	.inverted = true,
};

static const struct armada_thermal_data armada_ap806_data = {
	.is_valid = armada_is_valid,
	.init_sensor = armada_ap806_init_sensor,
	.is_valid_bit = BIT(16),
	.temp_shift = 0,
	.temp_mask = 0x3ff,
	.coef_b = -150000LL,
	.coef_m = 423ULL,
	.coef_div = 1,
	.inverted = true,
	.signed_sample = true,
	.needs_control0 = true,
};

static const struct armada_thermal_data armada_cp110_data = {
	.is_valid = armada_is_valid,
	.init_sensor = armada380_init_sensor,
	.is_valid_bit = BIT(10),
	.temp_shift = 0,
	.temp_mask = 0x3ff,
	.coef_b = 1172499100ULL,
	.coef_m = 2000096ULL,
	.coef_div = 4201,
	.inverted = true,
	.needs_control0 = true,
};

static const struct of_device_id armada_thermal_id_table[] = {
	{
		.compatible = "marvell,armadaxp-thermal",
		.data       = &armadaxp_data,
	},
	{
		.compatible = "marvell,armada370-thermal",
		.data       = &armada370_data,
	},
	{
		.compatible = "marvell,armada375-thermal",
		.data       = &armada375_data,
	},
	{
		.compatible = "marvell,armada380-thermal",
		.data       = &armada380_data,
	},
	{
		.compatible = "marvell,armada-ap806-thermal",
		.data       = &armada_ap806_data,
	},
	{
		.compatible = "marvell,armada-cp110-thermal",
		.data       = &armada_cp110_data,
	},
	{
		/* sentinel */
	},
};
MODULE_DEVICE_TABLE(of, armada_thermal_id_table);

static int armada_thermal_probe(struct platform_device *pdev)
{
	void __iomem *control = NULL;
	struct thermal_zone_device *thermal;
	const struct of_device_id *match;
	struct armada_thermal_priv *priv;
	struct resource *res;

	match = of_match_device(armada_thermal_id_table, &pdev->dev);
	if (!match)
		return -ENODEV;

	priv = devm_kzalloc(&pdev->dev, sizeof(*priv), GFP_KERNEL);
	if (!priv)
		return -ENOMEM;

	res = platform_get_resource(pdev, IORESOURCE_MEM, 0);
	priv->status = devm_ioremap_resource(&pdev->dev, res);
	if (IS_ERR(priv->status))
		return PTR_ERR(priv->status);

	res = platform_get_resource(pdev, IORESOURCE_MEM, 1);
	control = devm_ioremap_resource(&pdev->dev, res);
	if (IS_ERR(control))
		return PTR_ERR(control);

	priv->data = (struct armada_thermal_data *)match->data;

	/*
	 * Legacy DT bindings only described "control1" register (also referred
	 * as "control MSB" on old documentation). New bindings cover
	 * "control0/control LSB" and "control1/control MSB" registers within
	 * the same resource, which is then of size 8 instead of 4.
	 */
	if (resource_size(res) == LEGACY_CONTROL_MEM_LEN) {
		/* ->control0 unavailable in this configuration */
		if (priv->data->needs_control0) {
			dev_err(&pdev->dev, "No access to control0 register\n");
			return -EINVAL;
		}

		priv->control1 = control + LEGACY_CONTROL1_OFFSET;
	} else {
		priv->control0 = control + CONTROL0_OFFSET;
		priv->control1 = control + CONTROL1_OFFSET;
	}

	priv->data->init_sensor(pdev, priv);

	thermal = thermal_zone_device_register(dev_name(&pdev->dev), 0, 0, priv,
					       &ops, NULL, 0, 0);
	if (IS_ERR(thermal)) {
		dev_err(&pdev->dev,
			"Failed to register thermal zone device\n");
		return PTR_ERR(thermal);
	}

	platform_set_drvdata(pdev, thermal);

	return 0;
}

static int armada_thermal_exit(struct platform_device *pdev)
{
	struct thermal_zone_device *armada_thermal =
		platform_get_drvdata(pdev);

	thermal_zone_device_unregister(armada_thermal);

	return 0;
}

static struct platform_driver armada_thermal_driver = {
	.probe = armada_thermal_probe,
	.remove = armada_thermal_exit,
	.driver = {
		.name = "armada_thermal",
		.of_match_table = armada_thermal_id_table,
	},
};

module_platform_driver(armada_thermal_driver);

MODULE_AUTHOR("Ezequiel Garcia <ezequiel.garcia@free-electrons.com>");
MODULE_DESCRIPTION("Marvell EBU Armada SoCs thermal driver");
MODULE_LICENSE("GPL v2");
OpenPOWER on IntegriCloud