summaryrefslogtreecommitdiffstats
path: root/drivers/mtd/maps/db1x00-flash.c
blob: faa68ec569023d6f9cc61fe6b0fd6113a3b2899b (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
/*
 * Flash memory access on Alchemy Db1xxx boards
 * 
 * $Id: db1x00-flash.c,v 1.6 2004/11/04 13:24:14 gleixner Exp $
 *
 * (C) 2003 Pete Popov <ppopov@embeddedalley.com>
 * 
 */

#include <linux/config.h>
#include <linux/module.h>
#include <linux/types.h>
#include <linux/init.h>
#include <linux/kernel.h>

#include <linux/mtd/mtd.h>
#include <linux/mtd/map.h>
#include <linux/mtd/partitions.h>

#include <asm/io.h>

#ifdef 	DEBUG_RW
#define	DBG(x...)	printk(x)
#else
#define	DBG(x...)	
#endif

/* MTD CONFIG OPTIONS */
#if defined(CONFIG_MTD_DB1X00_BOOT) && defined(CONFIG_MTD_DB1X00_USER)
#define DB1X00_BOTH_BANKS
#elif defined(CONFIG_MTD_DB1X00_BOOT) && !defined(CONFIG_MTD_DB1X00_USER)
#define DB1X00_BOOT_ONLY
#elif !defined(CONFIG_MTD_DB1X00_BOOT) && defined(CONFIG_MTD_DB1X00_USER)
#define DB1X00_USER_ONLY
#endif

static unsigned long window_addr;
static unsigned long window_size;
static unsigned long flash_size;

static unsigned short *bcsr = (unsigned short *)0xAE000000;
static unsigned char flash_bankwidth = 4;

/* 
 * The Db1x boards support different flash densities. We setup
 * the mtd_partition structures below for default of 64Mbit 
 * flash densities, and override the partitions sizes, if
 * necessary, after we check the board status register.
 */

#ifdef DB1X00_BOTH_BANKS
/* both banks will be used. Combine the first bank and the first 
 * part of the second bank together into a single jffs/jffs2
 * partition.
 */
static struct mtd_partition db1x00_partitions[] = {
        {
                .name         =  "User FS",
                .size         =  0x1c00000,
                .offset       =  0x0000000
        },{
                .name         =  "yamon",
                .size         =  0x0100000,
		.offset       =  MTDPART_OFS_APPEND,
                .mask_flags   =  MTD_WRITEABLE
        },{
                .name         =  "raw kernel",
		.size         =  (0x300000-0x40000), /* last 256KB is env */
		.offset       =  MTDPART_OFS_APPEND,
        }
};
#elif defined(DB1X00_BOOT_ONLY)
static struct mtd_partition db1x00_partitions[] = {
        {
                .name         =  "User FS",
                .size         =  0x00c00000,
                .offset       =  0x0000000
        },{
                .name         =  "yamon",
                .size         =  0x0100000,
		.offset       =  MTDPART_OFS_APPEND,
                .mask_flags   =  MTD_WRITEABLE
        },{
                .name         =  "raw kernel",
		.size         =  (0x300000-0x40000), /* last 256KB is env */
		.offset       =  MTDPART_OFS_APPEND,
        }
};
#elif defined(DB1X00_USER_ONLY)
static struct mtd_partition db1x00_partitions[] = {
        {
                .name         =  "User FS",
                .size         =  0x0e00000,
                .offset       =  0x0000000
        },{
                .name         =  "raw kernel",
		.size         =  MTDPART_SIZ_FULL,
		.offset       =  MTDPART_OFS_APPEND,
        }
};
#else
#error MTD_DB1X00 define combo error /* should never happen */
#endif
#define NB_OF(x)  (sizeof(x)/sizeof(x[0]))

#define NAME     	"Db1x00 Linux Flash"

static struct map_info db1xxx_mtd_map = {
	.name		= NAME,
};

static struct mtd_partition *parsed_parts;
static struct mtd_info *db1xxx_mtd;

/*
 * Probe the flash density and setup window address and size
 * based on user CONFIG options. There are times when we don't
 * want the MTD driver to be probing the boot or user flash,
 * so having the option to enable only one bank is important.
 */
int setup_flash_params(void)
{
	switch ((bcsr[2] >> 14) & 0x3) {
		case 0: /* 64Mbit devices */
			flash_size = 0x800000; /* 8MB per part */
#if defined(DB1X00_BOTH_BANKS)
			window_addr = 0x1E000000;
			window_size = 0x2000000; 
#elif defined(DB1X00_BOOT_ONLY)
			window_addr = 0x1F000000;
			window_size = 0x1000000; 
#else /* USER ONLY */
			window_addr = 0x1E000000;
			window_size = 0x1000000; 
#endif
			break;
		case 1:
			/* 128 Mbit devices */
			flash_size = 0x1000000; /* 16MB per part */
#if defined(DB1X00_BOTH_BANKS)
			window_addr = 0x1C000000;
			window_size = 0x4000000;
			/* USERFS from 0x1C00 0000 to 0x1FC0 0000 */
			db1x00_partitions[0].size = 0x3C00000;
#elif defined(DB1X00_BOOT_ONLY)
			window_addr = 0x1E000000;
			window_size = 0x2000000;
			/* USERFS from 0x1E00 0000 to 0x1FC0 0000 */
			db1x00_partitions[0].size = 0x1C00000;
#else /* USER ONLY */
			window_addr = 0x1C000000;
			window_size = 0x2000000;
			/* USERFS from 0x1C00 0000 to 0x1DE00000 */
			db1x00_partitions[0].size = 0x1DE0000;
#endif
			break;
		case 2:
			/* 256 Mbit devices */
			flash_size = 0x4000000; /* 64MB per part */
#if defined(DB1X00_BOTH_BANKS)
			return 1;
#elif defined(DB1X00_BOOT_ONLY)
			/* Boot ROM flash bank only; no user bank */
			window_addr = 0x1C000000;
			window_size = 0x4000000;
			/* USERFS from 0x1C00 0000 to 0x1FC00000 */
			db1x00_partitions[0].size = 0x3C00000;
#else /* USER ONLY */
			return 1;
#endif
			break;
		default:
			return 1;
	}
	db1xxx_mtd_map.size = window_size;
	db1xxx_mtd_map.bankwidth = flash_bankwidth;
	db1xxx_mtd_map.phys = window_addr;
	db1xxx_mtd_map.bankwidth = flash_bankwidth;
	return 0;
}

int __init db1x00_mtd_init(void)
{
	struct mtd_partition *parts;
	int nb_parts = 0;
	
	if (setup_flash_params()) 
		return -ENXIO;

	/*
	 * Static partition definition selection
	 */
	parts = db1x00_partitions;
	nb_parts = NB_OF(db1x00_partitions);

	/*
	 * Now let's probe for the actual flash.  Do it here since
	 * specific machine settings might have been set above.
	 */
	printk(KERN_NOTICE "Db1xxx flash: probing %d-bit flash bus\n", 
			db1xxx_mtd_map.bankwidth*8);
	db1xxx_mtd_map.virt = ioremap(window_addr, window_size);
	db1xxx_mtd = do_map_probe("cfi_probe", &db1xxx_mtd_map);
	if (!db1xxx_mtd) return -ENXIO;
	db1xxx_mtd->owner = THIS_MODULE;

	add_mtd_partitions(db1xxx_mtd, parts, nb_parts);
	return 0;
}

static void __exit db1x00_mtd_cleanup(void)
{
	if (db1xxx_mtd) {
		del_mtd_partitions(db1xxx_mtd);
		map_destroy(db1xxx_mtd);
		if (parsed_parts)
			kfree(parsed_parts);
	}
}

module_init(db1x00_mtd_init);
module_exit(db1x00_mtd_cleanup);

MODULE_AUTHOR("Pete Popov");
MODULE_DESCRIPTION("Db1x00 mtd map driver");
MODULE_LICENSE("GPL");
OpenPOWER on IntegriCloud