summaryrefslogtreecommitdiffstats
path: root/arch/arm/mach-omap2/omap_twl.c
diff options
context:
space:
mode:
Diffstat (limited to 'arch/arm/mach-omap2/omap_twl.c')
-rw-r--r--arch/arm/mach-omap2/omap_twl.c60
1 files changed, 0 insertions, 60 deletions
diff --git a/arch/arm/mach-omap2/omap_twl.c b/arch/arm/mach-omap2/omap_twl.c
index 615e5b1fb025..6bf626700557 100644
--- a/arch/arm/mach-omap2/omap_twl.c
+++ b/arch/arm/mach-omap2/omap_twl.c
@@ -46,15 +46,8 @@
static bool is_offset_valid;
static u8 smps_offset;
-/*
- * Flag to ensure Smartreflex bit in TWL
- * being cleared in board file is not overwritten.
- */
-static bool __initdata twl_sr_enable_autoinit;
-#define TWL4030_DCDC_GLOBAL_CFG 0x06
#define REG_SMPS_OFFSET 0xE0
-#define SMARTREFLEX_ENABLE BIT(3)
static unsigned long twl4030_vsel_to_uv(const u8 vsel)
{
@@ -251,18 +244,6 @@ int __init omap3_twl_init(void)
if (!cpu_is_omap34xx())
return -ENODEV;
- /*
- * The smartreflex bit on twl4030 specifies if the setting of voltage
- * is done over the I2C_SR path. Since this setting is independent of
- * the actual usage of smartreflex AVS module, we enable TWL SR bit
- * by default irrespective of whether smartreflex AVS module is enabled
- * on the OMAP side or not. This is because without this bit enabled,
- * the voltage scaling through vp forceupdate/bypass mechanism of
- * voltage scaling will not function on TWL over I2C_SR.
- */
- if (!twl_sr_enable_autoinit)
- omap3_twl_set_sr_bit(true);
-
voltdm = voltdm_lookup("mpu_iva");
omap_voltage_register_pmic(voltdm, &omap3_mpu_pmic);
@@ -271,44 +252,3 @@ int __init omap3_twl_init(void)
return 0;
}
-
-/**
- * omap3_twl_set_sr_bit() - Set/Clear SR bit on TWL
- * @enable: enable SR mode in twl or not
- *
- * If 'enable' is true, enables Smartreflex bit on TWL 4030 to make sure
- * voltage scaling through OMAP SR works. Else, the smartreflex bit
- * on twl4030 is cleared as there are platforms which use OMAP3 and T2 but
- * use Synchronized Scaling Hardware Strategy (ENABLE_VMODE=1) and Direct
- * Strategy Software Scaling Mode (ENABLE_VMODE=0), for setting the voltages,
- * in those scenarios this bit is to be cleared (enable = false).
- *
- * Returns 0 on success, error is returned if I2C read/write fails.
- */
-int __init omap3_twl_set_sr_bit(bool enable)
-{
- u8 temp;
- int ret;
- if (twl_sr_enable_autoinit)
- pr_warning("%s: unexpected multiple calls\n", __func__);
-
- ret = twl_i2c_read_u8(TWL_MODULE_PM_RECEIVER, &temp,
- TWL4030_DCDC_GLOBAL_CFG);
- if (ret)
- goto err;
-
- if (enable)
- temp |= SMARTREFLEX_ENABLE;
- else
- temp &= ~SMARTREFLEX_ENABLE;
-
- ret = twl_i2c_write_u8(TWL_MODULE_PM_RECEIVER, temp,
- TWL4030_DCDC_GLOBAL_CFG);
- if (!ret) {
- twl_sr_enable_autoinit = true;
- return 0;
- }
-err:
- pr_err("%s: Error access to TWL4030 (%d)\n", __func__, ret);
- return ret;
-}
OpenPOWER on IntegriCloud