summaryrefslogtreecommitdiffstats
path: root/net/rds/ib_send.c
diff options
context:
space:
mode:
authorSantosh Shilimkar <santosh.shilimkar@oracle.com>2018-10-13 22:13:23 +0800
committerSantosh Shilimkar <santosh.shilimkar@oracle.com>2019-02-04 14:59:13 -0800
commitfd261ce6a30e01ad67c416e2c67e263024b3a6f9 (patch)
treeb54d7fe0fe3d096c3cf8c9bdab695aa563cab3bb /net/rds/ib_send.c
parent56dc8bce9f761cf61258e25d96dec4072273d8db (diff)
downloadblackbird-op-linux-fd261ce6a30e01ad67c416e2c67e263024b3a6f9.tar.gz
blackbird-op-linux-fd261ce6a30e01ad67c416e2c67e263024b3a6f9.zip
rds: rdma: update rdma transport for tos
For RDMA transports, RDS TOS is an extension of IB QoS(Annex A13) to provide clients the ability to segregate traffic flows for different type of data. RDMA CM abstract it for ULPs using rdma_set_service_type(). Internally, each traffic flow is represented by a connection with all of its independent resources like that of a normal connection, and is differentiated by service type. In other words, there can be multiple qp connections between an IP pair and each supports a unique service type. The feature has been added from RDSv4.1 onwards and supports rolling upgrades. RDMA connection metadata also carries the tos information to set up SL on end to end context. The original code was developed by Bang Nguyen in downstream kernel back in 2.6.32 kernel days and it has evolved over period of time. Reviewed-by: Sowmini Varadhan <sowmini.varadhan@oracle.com> Signed-off-by: Santosh Shilimkar <santosh.shilimkar@oracle.com> [yanjun.zhu@oracle.com: Adapted original patch with ipv6 changes] Signed-off-by: Zhu Yanjun <yanjun.zhu@oracle.com>
Diffstat (limited to 'net/rds/ib_send.c')
-rw-r--r--net/rds/ib_send.c5
1 files changed, 3 insertions, 2 deletions
diff --git a/net/rds/ib_send.c b/net/rds/ib_send.c
index 4e0c36acf866..09c46f2e97fa 100644
--- a/net/rds/ib_send.c
+++ b/net/rds/ib_send.c
@@ -305,8 +305,9 @@ void rds_ib_send_cqe_handler(struct rds_ib_connection *ic, struct ib_wc *wc)
/* We expect errors as the qp is drained during shutdown */
if (wc->status != IB_WC_SUCCESS && rds_conn_up(conn)) {
- rds_ib_conn_error(conn, "send completion on <%pI6c,%pI6c> had status %u (%s), disconnecting and reconnecting\n",
- &conn->c_laddr, &conn->c_faddr, wc->status,
+ rds_ib_conn_error(conn, "send completion on <%pI6c,%pI6c,%d> had status %u (%s), disconnecting and reconnecting\n",
+ &conn->c_laddr, &conn->c_faddr,
+ conn->c_tos, wc->status,
ib_wc_status_msg(wc->status));
}
}
OpenPOWER on IntegriCloud